Processing math: 100%

《污水处理厂低碳运行评价技术规范》标准解读及案例展示

王洪臣, 陈加波, 张景炳, 姜昭, 李乾岗, 邵宇婷, 张彤彤, 陈慧玲. 《污水处理厂低碳运行评价技术规范》标准解读及案例展示[J]. 环境工程学报, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
引用本文: 王洪臣, 陈加波, 张景炳, 姜昭, 李乾岗, 邵宇婷, 张彤彤, 陈慧玲. 《污水处理厂低碳运行评价技术规范》标准解读及案例展示[J]. 环境工程学报, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
WANG Hongchen, CHEN Jiabo, ZHANG Jingbing, JIANG Zhao, LI Qiangang, SHAO Yuting, ZHANG Tongtong, CHEN Huiling. Standard interpretation and case presentation Technical Specification for Low-Carbon Operation Evaluation of Sewage Treatment Plant[J]. Chinese Journal of Environmental Engineering, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
Citation: WANG Hongchen, CHEN Jiabo, ZHANG Jingbing, JIANG Zhao, LI Qiangang, SHAO Yuting, ZHANG Tongtong, CHEN Huiling. Standard interpretation and case presentation Technical Specification for Low-Carbon Operation Evaluation of Sewage Treatment Plant[J]. Chinese Journal of Environmental Engineering, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110

《污水处理厂低碳运行评价技术规范》标准解读及案例展示

    作者简介: 王洪臣 (1964—) ,男,博士,教授,whc@ruc.edu.cn
    通讯作者: 王洪臣(1964—),男,博士,教授,whc@ruc.edu.cn
  • 中图分类号: X703

Standard interpretation and case presentation Technical Specification for Low-Carbon Operation Evaluation of Sewage Treatment Plant

    Corresponding author: WANG Hongchen, whc@ruc.edu.cn
  • 摘要: 为响应国家减污降碳政策的号召,满足污水处理行业碳排放核算与评价的实际需求,根据碳排放核算标准化工作需要,中国环境保护产业协会于2022年6月首次发布了污水处理厂低碳相关的团体标准——《污水处理厂低碳运行评价技术规范》(T/CAEPI-2022)。该标准是我国污水处理领域首个低碳团体标准,规定了以城镇污水处理厂为主的污水处理厂碳排放核算的方法和低碳运行的评价等级划分,适用于污水处理厂的碳排放核算、低碳运行评价、低碳设计和改造等方面。从标准制订背景出发,阐述了碳排放强度核算和评价的依据、基本条件、内容、流程,并通过案例以期为广大同行理解标准、落实标准和推广标准提供参考。
  • 药品和个人护理品类污染物(如内分泌干扰物、抗生素等)导致的水体污染问题是生态安全和人类身体健康的一大威胁[1-3]。基于过硫酸盐的高级氧化技术可通过产生羟基自由基(OH)、硫酸根自由基(SO4•−)、单线态氧(1O2)等活性氧物种降解水中多种类型的有机污染物,在药、护品类污染物处理方面受到了广泛关注[1]。与过一硫酸盐(peroxymonosulfate,PMS)相比,过二硫酸盐(peroxydisulfate,PDS)价格低廉、水溶性好、稳定性高便于储存和运输,已被广泛用于催化降解有机污染物[1]。PDS可通过热活化、碱活化、金属离子催化、金属氧化物催化等多种方法活化,其中基于纳米金属氧化物(如Co3O4等)的异相催化由于催化剂价格低廉、反应条件温和、催化活性高等优点,是目前研究的一个重要方向[2]。然而,纳米尺寸的金属氧化物分散于水中易团聚,导致催化剂活性位点暴露有限,并且分散于水中的纳米催化剂还存在难以分离和回收的问题,极大地限制了其应用。

    将金属氧化物纳米催化剂负载于活性炭、泡沫金属、矿物颗粒以及陶瓷膜等三维载体的表面,不仅可以有效缓解氧化物纳米颗粒的团聚问题,而且便于分离和回收,对纳米金属氧化物活化过硫酸盐降解有机物具有重要意义[4]。现阶段,金属氧化物主要通过浆料涂覆的方式负载于载体表面,合成方法简单但稳定性较差[5]。添加高分子粘结剂可增强其稳定性,但催化体系中引入导电性较差的高分子不利于过硫酸活化过程中电子的转移,同时添加粘结剂也可能会带来二次污染[6]。因此,亟需发展一种可将金属氧化物原位负载于三维载体表面的绿色合成方法。植物多酚如单宁酸(tannic acid,TA)普遍存在于植物的根、茎、叶及果实中,是一种价格低廉的生物质[7]。TA分子富含邻二酚羟基,具有较强的金属离子络合能力和优异的表面粘附性能,可与多种金属离子(Co2+、Fe2+、Cu2+等)在聚乙烯球、陶瓷、玻璃等不同载体表面配位形成金属-多酚配合物[7]。作为由金属离子和有机配体组成的复合物,金属-多酚配合物可进一步热解制成不同种类的金属氧化物,并且研究表明有机配体TA分解还会产生多孔结构而形成多孔结构的金属氧化物[8]

    基于TA分子的金属离子络合能力和表面粘附性能,本研究以具有稳定物理化学性质且价格低廉的气泡石为载体,通过在其表面包覆Co2+与TA的配合物,进一步热解将纳米尺寸的Co3O4原位负载于气泡石表面,制备易分离回收的负载型Co3O4催化剂,通过SEM、XRD、ICP等详细分析了负载型Co3O4的结构和组成。利用负载型Co3O4催化剂活化PDS降解水中的双酚A(bis-phenol A,BPA)、磺胺甲恶唑(sulfamethoxazole,SMX)等药、护品类有机污染物,分析了溶液初始pH、PDS浓度、催化剂投加量、共存化学组分等对有机物降解性能的影响,并通过电子顺磁共振分析、化学淬灭实验、光谱分析等手段深入分析了PDS的活化机制和有机物的降解机理。

    主要试剂包括六水合硝酸钴(Co(NO3)2·6H2O)、单宁酸(tannic acid)、双酚A(bisphenol A)、盐酸(HCl,1 mol·L−1)、过硫酸钠(sodium persulfate, Na2S2O8)、氢氧化钠(NaOH,1 mol·L−1)、叔丁醇(tert-butyl alcohol, TBA)、对苯醌(p-benzoquinone, BQ)、碳酸钠(Na2CO3)、氯化钠(NaCl)、硝酸钠(NaNO3)、硫酸钠(Na2SO4)、腐殖酸(HA)、甲醇、乙腈、无水乙醇等,所有试剂均为分析纯,实验用水为超纯水。

    1)负载型Co3O4的制备:将尺寸0.5 cm×0.5 cm×0.5 cm的气泡石颗粒置于Co(NO3)2与TA的混合溶液中,利用TA分子的表面粘附特性及其与Co2+的配位反应,在气泡石颗粒表面形成Co-TA包覆层,进一步在空气气氛下焙烧制得负载于气泡石表面的Co3O4催化剂。具体步骤如下:将5 g Co(NO3)2和10 g TA依次溶解于250 mL纯水,然后加入30 g气泡石载体搅拌30 min,加入5 mL氨水后继续搅拌1 h,将修饰后的气泡石用纯水反复清洗。重复上述负载步骤4次后,制得负载有Co-TA配合物的气泡石颗粒,充分干燥后将其置于马弗炉中在400 °C下焙烧2 h (升温速率设置为2 ℃·min−1),即制得负载型Co3O4催化剂。

    2)材料表征:通过场发射扫描电子显微镜(Hitachi, S-4800)分析负载型Co3O4的形貌与元素组成,利用Rigaku Ultimate IV型X射线衍射(XRD)表征其晶体结构,借助X射线光电子能谱(XPS)研究催化剂反应前后各元素的化学价态,采用电感耦合等离子体发射光谱仪(ICP, NexION 350D)测定浸出钴离子的浓度以及气泡石颗粒表面Co3O4的负载量。ATR-FTIR测试以超纯水为背景,将PDS与Co3O4纳米催化剂的混合物滴至ATR附件晶体表面,在400~3000 cm−1内至少扫描3次,扫描分辨率为4 cm−1

    3)BPA降解实验:本研究通过催化降解BPA评价负载型Co3O4活化PDS的性能。室温条件下,配制50 mL 0.04 mmol·L−1的BPA溶液,加入3.0 g负载型Co3O4催化剂和0.5 mL 40 mmol·L−1的PDS溶液,然后于特定时间取1 mL水样与0.5 mL甲醇混合以终止反应,进一步用0.22 μm微孔滤膜过滤后,通过高效液相色谱仪测定BPA的浓度,流动相为水和乙腈的混合溶液,两者的体积比为1:1,流速为1 mL·min−1

    图1为气泡石载体负载Co3O4前后的照片及其表面Co3O4纳米催化剂的微观结构。如图1(a)所示,气泡石表面粗糙呈白色,负载Co3O4后变为灰褐色(图1(b)),表明Co3O4纳米催化剂成功负载于其表面。通过SEM表征了气泡石表面Co3O4纳米催化剂的微观结构,如图1(c)所示,气泡石光滑的表面存在大量的纳米颗粒团簇,进一步表明Co3O4纳米催化剂的成功负载。纳米团簇的高倍SEM图表明Co3O4纳米催化剂呈多孔结构(图1(d)),这可能是Co-TA配合物中有机组分TA分解导致的。多孔结构利于催化位点的充分暴露,利于PDS的活化和有机污染物的降解[9]

    图 1  气泡石与气泡石负载Co3O4的电子照片与SEM分析
    Figure 1.  Digital images of airstone with and without Co3O4 and their SEM analysis

    图2(a)为Co-TA焙烧衍生粉体Co3O4及气泡石负载Co3O4的XRD谱图。粉体催化剂在2θ为31.27°、36.85°、44.8°、59.35°、65.23°的衍射峰分别对应于立方相Co3O4的(220)、(311)、(400)、(511)和(440)晶面(JCPDS-no.42-1467)。气泡石的XRD图谱表明其主要成分为SiO2 (JCPDS-no.78-2315);SiO2化学性质稳定,便于在复杂环境中使用。气泡石表面负载催化剂后,在2θ为31.27°、44.81°检测到了属于Co3O4的衍射峰,分别对应于立方相Co3O4的(220)和(400)晶面,进一步表明Co3O4成功负载于气泡石表面。通过热重分析研究了Co-TA配合物的热分解过程。如图2(b)所示,Co-TA配合物的残余质量在20~400 °C内持续降低,这主要归咎配合物表面水分子的脱附以及有机配体TA的氧化分解[10]。DTA分析表明Co-TA分解过程中在380 °C出现了明显的吸热峰,表明Co-TA热解生成了新的固相。400 °C后配合物的质量损失保持不变,表明Co-TA中的有机配体在400 °C下完全分解,因此本研究将负载型Co3O4催化剂的合成温度设定为400 °C。通过ICP-MS分析了气泡石表面Co3O4的负载量,结果表明每克气泡石表面负载有1.25 mg的Co3O4纳米颗粒。

    图 2  负载型Co3O4和粉体Co3O4的XRD以及Co-TA配合物的热解分析
    Figure 2.  XRD patterns for powdery Co3O4 and supported Co3O4 and TG curve for Co-TA polymer

    在反应温度为(25±1) °C、负载型Co3O4投加量60 g·L−1(即0.075 g·L−1 Co3O4纳米颗粒)、BPA初始浓度为0.04 mmol·L−1、PDS初始浓度为0.4 mmol·L−1和pH为7的条件下测试了负载型Co3O4活化PDS降解BPA的性能。如图3(a)所示,PDS氧化降解BPA的能力有限,120 min内BPA的去除率仅为9%,同时负载型Co3O4仅吸附了4.8%的BPA。负载型Co3O4活化PDS可有效降解BPA,120 min内BPA的去除率达到了100%。BPA的降解遵循拟一级反应动力学,反应动力学常数为0.04 min−1 (图3(b))。ICP分析表明催化反应结束后溶液中Co2+的质量浓度为0.55 mg·L−1,低于地表水环境质量标准(GB 3838-2002D)规定的标准(1.0 mg·L−1),表明负载型Co3O4具有良好的稳定性。溶出的Co2+在相同实验条件下催化PDS仅降解了11%的BPA,表明负载型Co3O4主要通过异相催化反应降解有机物[10]图3(b)反映了负载型Co3O4活化PDS降解不同类型有机物的性能,苯酚(Phenol)、对乙酰氨基酚(AAP)、磺胺甲恶唑(SMX)均可被有效去除,相同反应条件下120 min内的去除率分别为78.2%、93.6%、67.3%,对应的反应动力学常数分别为0.01、0.02、0.01 min−1(图3(d))。以上结果表明负载型Co3O4活化PDS可催化降解不同类型的药、护品类有机污染物。

    图 3  负载型Co3O4活化PDS降解不同有机物的性能
    Figure 3.  Degradation of different organic pollutants by PDS activated over supported Co3O4

    图4(a)反映了溶液初始pH分别为3、5、7、9、11时,负载型Co3O4活化PDS降解BPA的性能。在pH=3~9内,BPA均可得到有效去除,120 min内BPA的去除率均达到100%,同时反应速率也并未受到显著影响;然而,当pH提升至11时,BPA的降解受到抑制,120 min内BPA的去除率降低了24.4%,反应速率也由中性时的0.04 min−1降至0.01 min−1,这可能是由于碱性条件下OH的氧化还原电位降低所致[11]图4(b)为不同PDS投加量下,负载型Co3O4对BPA的催化降解性能。当PDS浓度由0.1 mmol·L−1增加到0.4 mmol·L−1时,BPA的去除率从20.9%增加到98.2%,反应速率也由0.002 min−1提升至0.03 min−1。增加PDS的浓度可增加活性氧物种的生成量,进而促进有机物的催化降解[12]。然而,进一步增加PDS的浓度至0.8 mmol·L−1和1.6 mmol·L−1时,BPA的降解性能并未得到进一步提升。这可能是由于负载型Co3O4的催化位点有限,不能完全活化反应体系中的PDS[13]。增加催化剂的投加量可提供更多的催化位点而充分活化PDS,进而产生更多的活性氧物种而显著提升有机物的降解效率[14]。如图4(c)所示,在BPA溶液体积为50 mL的情况下,当负载型Co3O4催化剂的投加量由1.5 g增加至3.0 g时,BPA的降解速率由0.02 min−1提高至0.037 min−1,当催化剂的投加量进一步增加至6.0 g时,BPA在60 min即可被完全去除,降解速率达0.039 min−1。这表明增加负载型Co3O4的剂量可显著提升PDS的有效利用率。

    图 4  负载型Co3O4活化PDS降解BPA的影响因素
    Figure 4.  Effect of operation parameters on BPA removal in the supported Co3O4/PDS system

    为考察水中常见无机阴离子对负载型Co3O4活化PDS降解有机物性能的影响,研究了Cl、NO3、CO32−对BPA去除效率和降解速率的影响。如图4(d)所示,在负载型Co3O4/PDS体系中加入10 mmol·L−1 Cl并未降低BPA的去除效率,同样加入10 mmol·L−1的NO3也未影响BPA的去除。Co3O4活化PDS降解有机物主要有2种途径:一种是基于SO4•−和OH的自由基氧化;另一种是基于单线态氧(1O2)的非自由基氧化[15]。在自由基途径中,Cl、NO3等无机阴离子会竞争消耗强氧化性的SO4•−和OH,进而抑制有机污染物的降解[16-18]。在本研究中,Cl和NO3对BPA的去除影响较弱,表明自由基氧化不是Co3O4活化PDS降解有机物的主要途径。然而,向反应体系中添加10 mmol·L−1的CO32−可显著抑制BPA的去除,同样反应条件下BPA仅去除了16.64%,同时反应速率由0.04 min−1降低至了0.001 min−1。CO32−是一种常用的1O2淬灭剂,其对BPA降解的显著抑制表明负载型Co3O4活化PDS降解有机物是1O2主导的非自由途径[19]。除了无机阴离子,天然有机物如腐殖酸(HA)也是一种常见的水体背景成分[6]。在10 mg·L−1 HA存在的情况下,负载型Co3O4催化降解有机物的效率也未受到显著影响,进一步说明本反应体系中有机物的降解为非自由基途径[20]。综上所述,负载型Co3O4/PDS体系不仅能够在较宽的pH范围内降解有机物,而且对无机阴离子和腐殖酸等常见的水体背景成分具有较强的抗干扰能力,因此,有着较强的应用潜力。

    为明确负载型Co3O4活化PDS降解有机物的机理,通过EPR鉴定分析了该体系产生的活性氧的种类。如图5(a)所示,当仅有PDS时,以DMPO为自旋捕获剂未检测到任何信号,而当加入负载型Co3O4催化剂后,EPR谱图观测到了峰强度为1: 2 : 2 : 1的特征峰,这是催化产生的OH被DMPO捕获所致,表明负载型Co3O4活化PDS产生了OH•[21]。此外,以TEMP为1O2捕获剂还检测到了TEMP-1O2的特征峰,因此,负载型Co3O4活化PDS也产生了1O2[22]。进一步通过化学淬灭实验判别了反应体系中OH1O2对BPA降解的贡献。图5(b)反映了不同浓度MeOH的淬灭效果,可以看出MeOH对BPA的降解影响有限,在1 000 mmol·L−1 MeOH存在的情况下,BPA的去除率仍高达94.7%。MeOH可与SO4•−和OH快速反应,反应速率常数分别为k 分别为 2.5×107 (mol·s)−1和9.7×108 (mol·s)−1,是常用的自由基淬灭剂;MeOH对负载型Co3O4/PDS有限的淬灭能力表明该体系降解有机物的过程中,自由基的氧化作用有限[7]。然而,L-组氨酸可显著抑制BPA的降解,如图5(c)所示,1 mmol·L−1的组氨酸使得BPA的降解率由100%降低至89%;当L-组氨酸的浓度增加至5 mmol·L−1时,BPA的去除率进一步降低至21.98%,反应速率也由0.04 min−1降低至0.002 min−1。L-组氨酸具有一定的还原性,可能会消耗PDS而降低负载型Co3O4催化降解BPA的能力[23]。为排除L-组氨酸消耗PDS对淬灭实验的干扰,研究了不同浓度L-组氨酸对PDS的降解效率。如图5(d)所示,L-组氨酸分解PDS的能力有限,例如5 mmol·L−1的L-组氨酸在120 min内仅分解了5.8%的PDS。因此,L-组氨酸对负载型Co3O4/PDS降解BPA的抑制作用主要归咎于其对活性氧物种的淬灭,而L-组氨酸是常用的1O2淬灭剂,这表明负载型Co3O4活化PDS降解有机物是以1O2为主导的非自由基氧化途径。过渡金属氧化物活化PDS产生1O2已被广泛报道,有研究表明,O2•−1O2生成的重要中间体(2O2·+2H2O21O2+2OH+H2O2)[24]。本研究中,化学淬灭实验结果表明BQ(一种常用的O2•−淬灭剂)[25]可显著抑制BPA的降解。如图5(e)所示,加入5 mmol·L−1 BQ后BPA的去除率由100%降低至48.4%,同时速率常数由0.04 min−1降至0.008 min−1(图5(f)),表明O2•−的淬灭可显著抑制BPA的降解。O2•−的氧化还原电位较低,本身不能氧化分解有机物[24],而1O2是本研究中BPA降解的主要活性物种,这说明O2•−1O2形成的中间体,也就是说负载型Co3O4活化PDS先生成了O2•−,O2•−再进一步反应生成1O2

    图 5  负载型Co3O4活化PDS的电子自旋共振测试和淬灭实验
    Figure 5.  EPR spectra and quenching experiments on BPA removal

    过渡金属氧化物主要通过金属离子的价态循环活化过硫酸盐[26]。为解析负载型多孔Co3O4活化PDS的机理,通过XPS分析了Co3O4中Co元素的价态及其反应前后含量的变化。如图6(a)所示,Co2p在794.9 eV和779.7 eV的特征峰分别对应于Co2p1/2和Co2p3/2,而Co2p3/2的高分辨XPS谱图拟合结果表明,781.2 eV和779.7 eV处的峰分别对应于Co2+和Co3+,所占比例分别为34.2%和54.5%。反应后,Co3O4表面Co2+、Co3+比例变化表明Co3+/Co2+的氧化还原参与了PDS的活化[27]。进一步通过原位ATR-FTIR分析研究了PDS分子在负载型Co3O4表面的反应机理。如图6(b)所示,在1 050 cm−1和1 272 cm−1处检测到PDS振动峰,加入Co3O4催化剂后在其表面观测到了PDS的特征峰的位置并且未发生偏移,表明PDS吸附于Co3O4催化剂的表面。此外,在Co3O4/PDS体系中还观测到了SO42‒的特征峰(1 107 cm−1),表明Co3O4活化PDS产生了SO42‒;随着反应时间的增加PDS特征峰的强度逐渐降低,而SO42‒特征峰的强度逐渐增加,表明PDS在Co3O4催化剂表面持续分解[1]

    图 6  负载型Co3O4活化PDS的机理研究
    Figure 6.  Mechanism of PDS activated over the supported Co3O4 catalyst

    金属氧化物(MOx)活化过硫酸盐时,吸附于其表面的水分子会解离形成MOx-OH[19]。因此,结合XPS和ATR-FTIR分析,提出了负载型Co3O4活化PDS降解BPA的可能反应机理(图7)。首先,PDS分子通过氢键与[≡Co3+—OH]2+结合形成[≡Co3+—O—O—SO3]+络合物(式(1)),该络合物具有较高的氧化电势,还原PDS分子生成O2•−,同时Co3+被还原为Co2+形成中间态[≡Co2+—OH] (式(2)),随之生成的O2•−进一步反应生成1O2 (式(3))。中间态[≡Co2+—O—O—SO3]通过内电子转移被氧化为≡Co3+—OH,同时生成少量的自由基(式(4))。如上所述,负载型Co3O4/PDS体系中自由基对有机物的降解贡献有限,因此1O2进一步氧化有机物将其分解为中间产物或者H2O和CO2 (式(5))。本研究中,负载型Co3O4有效活化PDS主要有2点原因,一是负载型Co3O4避免了纳米催化剂的团聚,可暴露更多的活性位点而提升催化效率;另一方面,Co-TA配合物热解会产生富含氧缺陷的Co3O4[28],而氧缺陷可有效提升PDS分子在Co3O4表面的吸附,也会提升内电子催化PDS的效能。

    图 7  负载型Co3O4活化PDS降解BPA的机理示意图
    Figure 7.  Schema for BPA degradation by PDS activated over the supported Co3O4 catalyst
    2[Co3+OH]2++HS2O82[Co3+OOSO3]++3H+ (1)
    2[Co3+OOSO3]++4H2O+S2O822[Co2+OH]+4SO42+2O2·+6H+ (2)
    2O2·+2H2O21O2+2OH+H2O2 (3)
    [Co2+OOSO3]+H2OCo3+OH+SO4·+OH· (4)
    1O2+H2O+CO2+ (5)

    催化剂的稳定性是衡量其实际应用潜力的一个重要因素,本研究通过循环降解实验研究了负载型Co3O4的稳定性。如图8(a)所示,3次循环后负载型Co3O4对BPA的去除率仍保持在89%,表明负载型Co3O4具有良好的稳定性。循环降解过程中催化活性的轻微降低可能是BPA的降解产物堵塞活性位点导致的[10]。此外,XRD分析表明循环使用后负载型Co3O4的晶相没有明显变化(图2(a)),进一步说明负载型Co3O4具有良好的稳定性。负载型Co3O4可有效矿化BPA(图8(b)),TOC去除率高达73%,而且3次循环后TOC的去除率仍高达63%,表明负载型Co3O4可持续稳定地处理水中酚类有机污染物。

    图 8  循环降解过程中BPA的去除性能和TOC的去除效率
    Figure 8.  Removal of BPA and corresponding TOC during the consecutive runs over the supported Co3O4

    1)基于植物多酚的界面配位原理,通过在三维矿物载体表面原位负载Co3O4纳米颗粒制得了易分离回收的负载型Co3O4催化剂,比Co3O4粉体催化剂展现出更优异的催化活性和良好的稳定性。

    2)负载型Co3O4催化剂活化PDS可高效降解BPA、SMX、AAP等多种类型的药、护品类有机污染物,中性条件下,负载型Co3O4投加量为60 g·L−1(即0.075 g·L−1 Co3O4纳米颗粒),在BPA/PDS摩尔比为1:10的情况下可在120 min内将BPA完全降解。

    3)负载型Co3O4主要通过内电子转移活化PDS,降解有机物时自由基氧化的作用有限,主要是1O2主导的非自由基氧化途径,对无机阴离子和腐殖酸等水体背景成分有着较强的抗干扰能力,在实际水体处理方面展现出广阔的应用前景。

  • 图 1  污水处理厂低碳运行评价流程示意图

    Figure 1.  Diagram of sewage low carbon operation evaluation process

    表 1  污水处理厂低碳运行评价指标体系

    Table 1.  Low-carbon operation evaluation index system of sewage treatment plant

    分类一级指标二级指标其他指标与系数
    定量评价评价碳排放强度 (EP) 直接碳排放修正强度 (Edc) 直接碳排放强度 (Ed)
    总氮去除率修正系数 (k1)
    间接碳排放修正强度 (Eic) 间接碳排放强度 (Ei)
    处理规模修正系数 (k2)
    耗氧污染物削减量修正系数 (k3)
    出水排放标准修正系数 (k4)
    臭气控制程度修正系数 (k5)
    定性评价低碳行为设施设备低碳改造
    优化运行
    低碳建设
    监测与核算
    分类一级指标二级指标其他指标与系数
    定量评价评价碳排放强度 (EP) 直接碳排放修正强度 (Edc) 直接碳排放强度 (Ed)
    总氮去除率修正系数 (k1)
    间接碳排放修正强度 (Eic) 间接碳排放强度 (Ei)
    处理规模修正系数 (k2)
    耗氧污染物削减量修正系数 (k3)
    出水排放标准修正系数 (k4)
    臭气控制程度修正系数 (k5)
    定性评价低碳行为设施设备低碳改造
    优化运行
    低碳建设
    监测与核算
    下载: 导出CSV

    表 2  污水处理厂低碳运行评价资料收集表1

    Table 2.  Data collection table 1 for low-carbon operation evaluation of sewage treatment plant

    污水处理厂设计进水水量/ (m3∙d−1) 工业废水进水比例/%排放限值 (COD) / (mg∙L−1) 型式除臭程度日进水水量/ (m3∙d−1) 进水COD/(mg∙L−1) 进水BOD5/ (mg∙L−1) 进水氨氮/ (mg∙L−1) 进水总氮/ (mg∙L−1) 出水COD/ (mg∙L−1) 出水BOD5/ (mg∙L−1) 出水氨氮/ (mg∙L−1) 出水总氮/ (mg∙L−1) 污泥产量/ (kg∙d−1) 脱水污泥含水率/%CH4回收体积/ (m3∙d−1)
    A50 0005.030地下式有除臭电耗18 9382991374550162.00.807.014780
    B70 000030地上式有除臭电耗53 5692361033842172.00.718.056 218790
    C40 0001030地上式有除臭电耗22 417140682635162.00.626.026740
    污水处理厂设计进水水量/ (m3∙d−1) 工业废水进水比例/%排放限值 (COD) / (mg∙L−1) 型式除臭程度日进水水量/ (m3∙d−1) 进水COD/(mg∙L−1) 进水BOD5/ (mg∙L−1) 进水氨氮/ (mg∙L−1) 进水总氮/ (mg∙L−1) 出水COD/ (mg∙L−1) 出水BOD5/ (mg∙L−1) 出水氨氮/ (mg∙L−1) 出水总氮/ (mg∙L−1) 污泥产量/ (kg∙d−1) 脱水污泥含水率/%CH4回收体积/ (m3∙d−1)
    A50 0005.030地下式有除臭电耗18 9382991374550162.00.807.014780
    B70 000030地上式有除臭电耗53 5692361033842172.00.718.056 218790
    C40 0001030地上式有除臭电耗22 417140682635162.00.626.026740
    下载: 导出CSV

    表 3  污水处理厂低碳运行评价资料收集表2

    Table 3.  Data collection table 2 for low-carbon operation evaluation of sewage treatment plant

    污水处理厂用于生产的外购总耗电量/ (kW·h∙d−1) 每日热能消耗量 (折合为标准煤量) / (kg∙d−1) 每日化石燃料种类及其使用量(折合为标准煤量)/ (kg∙d−1) 每日化学药剂种类和纯品重量/ (kg∙d−1)
    A15 81300乙酸钠878、聚丙烯酰胺27、聚合硫酸铝141、次氯酸钠644
    B24 78800除磷剂188、次氯酸钠1 744、聚丙烯酰胺49、碳源805
    C6 15800乙酸钠395、PAM聚丙烯酰胺17、聚合氯化铝169、次氯酸钠756
    污水处理厂用于生产的外购总耗电量/ (kW·h∙d−1) 每日热能消耗量 (折合为标准煤量) / (kg∙d−1) 每日化石燃料种类及其使用量(折合为标准煤量)/ (kg∙d−1) 每日化学药剂种类和纯品重量/ (kg∙d−1)
    A15 81300乙酸钠878、聚丙烯酰胺27、聚合硫酸铝141、次氯酸钠644
    B24 78800除磷剂188、次氯酸钠1 744、聚丙烯酰胺49、碳源805
    C6 15800乙酸钠395、PAM聚丙烯酰胺17、聚合氯化铝169、次氯酸钠756
    下载: 导出CSV

    表 4  污水处理厂低碳运行评价等级计算表

    Table 4.  Calculation table of low-carbon operation evaluation grade of sewage treatment plant

    污水处理厂总氮去除率修正系数k1处理规模修正系数k2耗氧污染物削减量修正系数k3出水排放标准修正系数k4臭气控制程度修正系数k5直接碳排放修正强度Edc/(kg∙m−3) 间接碳排放修正强度Eic/(kg∙m−3) 评价碳排放强度Ep/ (kg∙m−3) 评价碳排放强度分数F1低碳行为鼓励分数F2低碳运行评价总分数F评价等级
    A0.003 50.950.800.640.900.0650.350.41636163三级
    B0.007 41.000.970.640.950.0870.240.33758076二级
    C0.006 60.951.050.640.950.0630.190.25868486一级
    污水处理厂总氮去除率修正系数k1处理规模修正系数k2耗氧污染物削减量修正系数k3出水排放标准修正系数k4臭气控制程度修正系数k5直接碳排放修正强度Edc/(kg∙m−3) 间接碳排放修正强度Eic/(kg∙m−3) 评价碳排放强度Ep/ (kg∙m−3) 评价碳排放强度分数F1低碳行为鼓励分数F2低碳运行评价总分数F评价等级
    A0.003 50.950.800.640.900.0650.350.41636163三级
    B0.007 41.000.970.640.950.0870.240.33758076二级
    C0.006 60.951.050.640.950.0630.190.25868486一级
    下载: 导出CSV
  • [1] European Environment Agency European Commission, DG Climate Action. Annual European Union greenhouse gas inventory 1990–2020 and inventory report 2022 Submission to the UNFCCC Secretariat [EB/OL]. [2022-12-05]. https://www.eea.europa.eu//publications/annual-european-union-greenhouse-gas-1
    [2] U. S. Environmental Protection Agency. Inventory of U. S. Greenhouse Gas Emissions and Sinks: 1990–2019 [EB/OL]. [2022-10-22]. https://www.epa.gov/ghgemissions/inventory-us-greenhouse-gas-emissions-and-sinks-1990-2019
    [3] IPCC. The Intergovernmental Panel on Climate Change [EB/OL]. [2022-10-22]. https://www.ipcc.ch/
    [4] PARRAVICINI V, SVARDAL K, KRAMPE J. Greenhouse gas emissions from wastewater treatment plants[J]. Energy Procedia, 2016, 97: 246-253. doi: 10.1016/j.egypro.2016.10.067
  • 加载中
图( 1) 表( 4)
计量
  • 文章访问数:  6843
  • HTML全文浏览数:  6843
  • PDF下载数:  337
  • 施引文献:  0
出版历程
  • 收稿日期:  2022-10-24
  • 录用日期:  2023-02-18
  • 刊出日期:  2023-03-10
王洪臣, 陈加波, 张景炳, 姜昭, 李乾岗, 邵宇婷, 张彤彤, 陈慧玲. 《污水处理厂低碳运行评价技术规范》标准解读及案例展示[J]. 环境工程学报, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
引用本文: 王洪臣, 陈加波, 张景炳, 姜昭, 李乾岗, 邵宇婷, 张彤彤, 陈慧玲. 《污水处理厂低碳运行评价技术规范》标准解读及案例展示[J]. 环境工程学报, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
WANG Hongchen, CHEN Jiabo, ZHANG Jingbing, JIANG Zhao, LI Qiangang, SHAO Yuting, ZHANG Tongtong, CHEN Huiling. Standard interpretation and case presentation Technical Specification for Low-Carbon Operation Evaluation of Sewage Treatment Plant[J]. Chinese Journal of Environmental Engineering, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110
Citation: WANG Hongchen, CHEN Jiabo, ZHANG Jingbing, JIANG Zhao, LI Qiangang, SHAO Yuting, ZHANG Tongtong, CHEN Huiling. Standard interpretation and case presentation Technical Specification for Low-Carbon Operation Evaluation of Sewage Treatment Plant[J]. Chinese Journal of Environmental Engineering, 2023, 17(3): 705-712. doi: 10.12030/j.cjee.202210110

《污水处理厂低碳运行评价技术规范》标准解读及案例展示

    通讯作者: 王洪臣(1964—),男,博士,教授,whc@ruc.edu.cn
    作者简介: 王洪臣 (1964—) ,男,博士,教授,whc@ruc.edu.cn
  • 中国人民大学环境学院低碳水环境技术研究中心,北京 100872

摘要: 为响应国家减污降碳政策的号召,满足污水处理行业碳排放核算与评价的实际需求,根据碳排放核算标准化工作需要,中国环境保护产业协会于2022年6月首次发布了污水处理厂低碳相关的团体标准——《污水处理厂低碳运行评价技术规范》(T/CAEPI-2022)。该标准是我国污水处理领域首个低碳团体标准,规定了以城镇污水处理厂为主的污水处理厂碳排放核算的方法和低碳运行的评价等级划分,适用于污水处理厂的碳排放核算、低碳运行评价、低碳设计和改造等方面。从标准制订背景出发,阐述了碳排放强度核算和评价的依据、基本条件、内容、流程,并通过案例以期为广大同行理解标准、落实标准和推广标准提供参考。

English Abstract

  • 为响应“碳达峰、碳中和”国家战略,加快建立污水处理行业的低碳核算和评价标准体系,协同推进污水处理厂减污降碳,并引导污水处理厂实现精细化管理与低碳运行,特制定团体标准《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49—2022) 。该标准基于《2006 IPCC国家温室气体清单指南》 (IPCC即联合国政府间气候变化专门委员会,全称Intergovernmental Panel on Climate Change) ,从直接碳排放和间接碳排放两方面详细阐述了碳排放强度核算内容和步骤,最后梳理了污水处理厂低碳运行评价的基本条件及内容,以期为相关行业从业人员理解标准、落实标准提供参考。此标准由中国环境保护产业协会批准,经中国环保产业协会城镇污水处理分会组织制定,以中国人民大学为主要起草单位,于2022年6月6日发布,并于2022年7月1日起正式实施。

    • 污水处理行业是区域经济发展的重要引擎,其碳排放量约占全社会总碳排放的1%~3%[1]。到2030年,全球污水处理行业的CH4和N2O逸散量将分别超过6亿吨和1亿吨二氧化碳当量 (CO2-eq),约占非二氧化碳总排放量的4.5%,是重要的碳排放源[2]。因此,应率先将“低碳”贯穿到污水处理的发展理念、发展方式、产业结构、增长动力、效益评价等各环节中。目前,污水处理低碳发展面临诸多现实问题:对温室气体减排措施的研究不够深入,基础数据不足,监测手段缺乏,且实现污水处理行业碳减排的路径不够明确等。因此,亟需加强对污水处理碳排放的核算与评价,以促进减污降碳的进一步发展,其中指定相关规范性文件是污水处理行业低碳发展的重要保障。

      国际上已发布了多项碳排放核算政策与标准,其中,基于“碳足迹”对温室气体核算的包括ISO 19694《固定源排放—确定能量密集型行业的温室气体排放》系列标准、ISO 14067:2013《温室气体—产品碳足迹—量化与沟通的规则与指南》等,基于排放因子法的核算标准有《IPCC 2006年国家温室气体清单指南 2019修订版》。国内也已发布多项温室气体排放核算标准,包括国家标准《工业企业温室气体排放核算和报告通则》 (GB/T 32150-2015) 和12项针对具体行业的标准 (GB/T 32151.1~12) 。然而,不同行业的温室气体排放核算方法仍存在差异,污水处理行业缺少统一的碳核算方法和评价标准,并缺乏相关低碳建设、运营的理论指导,难以科学全面地评价污水处理厂低碳运行水平,污水处理的节能减排仍停留在经验层面。

      《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49—2022) 的制订可填补我国污水处理领域低碳核算和低碳运行评价标准的空白,完善我国低碳评价方法体系,在提标改造的同时实现减污降碳,为后续行业标准,以及国家标准、低碳认定细则的编制提供参考。

    • 1) 编制的政策、文件和标准依据。《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49-2022) 以习近平总书记生态文明建设理念为指导,以《2030年前碳达峰行动方案》、《国家适应气候变化战略2035》、《减污降碳协同增效实施方案》、《城镇污水处理厂运营质量评价标准》 (CJJ/T228-2014) 、《温室气体核算体系》和《温室气体——第一部:企业层面上温室气体排放和去除量化报告指南》 (ISO 14064-1:2018) 等国家和地方有关文件为依据。

      2) 标准的制订目标、基本原则。该标准的制订目标与减污降碳的目标紧密结合,旨在完善污水处理行业评价指标体系,指导污水处理厂低碳运行和实现碳减排目标。该标准制订的基本原则为:与国家和地方相关环境标准和污染物排放标准相协调的同时,从全局出发,兼顾全社会与全行业的综合效益,广泛调动各方积极性,综合分析实施标准的技术经济可行性,充分考虑标准使用要求,使该标准具有可操作性。

      3) 标准制订的方法和过程。在该标准制订过程中充分调查研究、广泛征求意见,并依靠系统的和科学的分析方法,考虑区域环境的特点和与现有标准的衔接,以提高标准的整体性、系统性和可行性。根据低碳运行评价内容的需要,该标准引用了密切相关的现行标准作为该标准的延伸技术规定,引用文件的管理规定和技术要求视为该标准的一部分。

    • 核算边界是重要的碳排放核算与评价依据。在时间边界上,污水处理厂运行包括污水进入污水处理厂的粗格栅后,经过一系列的一级处理、二级处理和三级处理后排出的过程。此过程包括去除污水中固体污染物质、有机污染物以及难降解有机和无机污染物等。具体在空间边界的体现,即污水在上述处理过程中厂界内各具体构筑物,因此,本标准的空间边界不包括办公区和污泥深度处理区 (即污泥脱水外的过程) 。

      本标准以城市污水处理厂为主,不包括工业污水处理厂和汇入较多工业污水的城镇污水处理厂。根据城镇污水处理厂的碳排放活动,确定以下6种碳排放类型:1) 全生命周期各个阶段直接燃烧消耗化石燃料的直接碳排放;2) 污水处理厂内各处理构筑物及传输过程由微生物为主产生并排放的CH4,N2O和非生源性CO2直接碳排放;3) 全生命周期各个阶段化石燃料生产电能、热能等过程产生的间接碳排放;4) 全生命周期所消耗材料,主要为化学药剂生产产生的间接碳排放;5) 运输材料过程所产生的直接碳排放;6) 资源、能源等回收形成的碳补偿。

    • 标准内容主要分为碳排放强度核算与低碳运行评价两部分。碳排放强度核算可分为直接碳排放核算和间接碳排放核算。评价指标体系分为定量评价和定性评价。定量评价是以碳排放核算为基础的评价;定性评价是对设施设备低碳改造、优化运行、低碳建设、监测与核算等低碳行为的评价。

    • 根据IPCC排放因子法[3]计算污水处理厂N2O、CH4和CO2的排放强度,计算公式见式 (1) 。

      式中:活动数据是污水处理过程中排放的温室气体和生产或消费活动的活动量,如污水处理构筑物产生的温室气体、化石燃料的消耗量、净购入的电量、化学药品的消耗量、净购入的热量等;排放因子是与活动水平数据对应的系数,表征单位生产或消费活动量的温室气体排放系数。排放因子与全球变暖潜能值GWP100参考自《IPCC 2006年国家温室气体清单指南 2019修订版》[3]

    • 直接碳排放为污水生物处理单元产生的N2O排放、CH4排放和化石燃料燃烧产生的CO2排放,如公式 (2) 所示。计算出的温室气体排放量乘相应气体的 GWP100,即为该气体直接碳排放强度值。IPCC认为污水处理厂由生物分解产生的CO2归为生源性碳,因此产生的CO2不纳入碳排放的计算[3]

      式中:碳排放强度单位为kg∙m−3,是以CO2排放当量计,即每方水排放碳强度为多少千克CO2-eq,本文所有碳排放强度皆为此单位,后不再赘述;Ed 为直接碳排放强度,kg∙m−3EN2O 为N2O直接碳排放强度,kg∙m−3ECH4为CH4直接碳排放强度,kg∙m−3ECO2 为CO2直接排放强度,kg∙m−3

    • 间接碳排放强度按公式 (3) 计算,包括电力、热力等能耗碳排放和化学药剂 (碳源、除磷药剂、脱水药剂、消毒药剂等) 消耗的物耗碳排放。

      式中:Ei为间接碳排放强度,kg∙m−3Ee 为电耗碳排放强度,kg∙m−3Eh 为热耗碳排放强度,kg∙m−3Ec 为物耗碳排放强度,kg∙m−3

    • 该标准主要适用于城镇污水处理厂碳排放核算和低碳运行水平的评价,进行核算与评价的污水处理厂应满足如下5个基本条件。1) 符合其他污染物排放标准,无超标现象。2) 评价周期为一年,一般从每年的1月1日至12月31日计,取日平均值,以避免一年中不同季节、不同月份或一天中不同时间的温度、湿度及其它因素引起的碳排放差异。3) 污水处理厂需完成环保验收才能参与评价,且要投产1年以上,以保证污水处理厂运行数据的准确性和有效性。4) 污水处理厂平均水量负荷率应该大于设计处理水量的50%,工业废水进水比例应小于10%;污水处理厂设计处理水量与实际处理水量差距过大,造成基础建设、设备采购、运行成本等方面碳排放增加,造成资源的浪费,也与低碳相悖。工业废水的汇入对城镇污水处理厂运行有一定影响,若出水需达标则则需要增加碳排放例如电耗或药剂,因此工业废水进水比例应小于10%。5) 监测、运行与样品采集、记录过程中均要遵循现行的标准和工艺运行管理原则。化验监测、日常化验检测项目及周期应遵循国家现行标准和工艺运行管理需要的原则。此外,污水处理厂应完整并准确记录工艺运行参数和能耗物耗等数据。规范样品的采集、化验、记录过程,确保核算与评价结果的准确性。

    • 根据文献资料与实践调研分析,评价指标体系分为定量评价指标和定性评价指标两大类,细分为二级评价指标体系 (表1) 。定量评价指标包括一级指标 (评价碳排放强度) 、二级指标 (直接碳排放修正强度、间接碳排放修正强度) 。定性评价指标包括一级指标 (低碳行为) 、二级指标 (设施设备低碳改造、优化运行、低碳建设、监测与核算) 。

    • (1) 碳排放修正强度分数

      针对污水处理过程的差异性,该标准提出归一化的碳排放评价方法。碳排放修正强度是对由于总氮去除率、处理规模、耗氧污染物削减量、出水排放标准以及臭气控制程度等因素导致的客观碳排放差异进行修正后的碳排放强度。为了避免不同污水处理厂的处理规模、总氮去除率、出水排放标准、耗氧污染物削减量和除臭程度差异的情况,确保污水处理厂低碳运行评价的有效性、合理性和公平性,在评价指标中提出了修正系数,用于碳排放强度的修正。修正系数是基于污水处理厂运行过程中上述因素对单位污水处理碳排放的影响系数。该标准确定了用于修正碳排放强度的5项修正系数,分别为总氮去除率修正系数k1、处理规模修正系数k2、耗氧污染物削减量修正系数k3、出水排放标准修正系数k4和臭气控制程度修正系数k5

      1) 总氮去除率修正系数k1。总氮去除率修正系数k1的提出是基于总氮去除率对直接碳排放的影响。污水处理厂的总氮去除率 (ηTN) 越高,N2O排放因子越低[4],直接碳排放强度越低。因此,采用总氮去除率修正系数k1修正直接碳排放强度。

      2) 处理规模修正系数k2。处理规模修正系数k2的提出是基于处理水量对电耗的影响。当处理规模较小时,吨水电耗较高;当处理规模较大时会呈现出一定的规模效应,吨水电耗较小。

      3) 耗氧污染物削减量修正系数k3。进水水质常见指标包括COD、BOD5、SS、NH4+-N、TN和TP这6项。其中,进水COD (或BOD5) 和NH4+-N (或TN) 的降解和转化需要消耗大量氧气,会直接增加电耗;TN的去除还可能需要外加碳源,增加药耗;TP的去除需要化学除磷药剂,同样会增加药耗。因此,耗氧污染物削减量修正系数k3的提出是基于污染物削减量对间接碳排放强度的影响。

      4) 出水排放标准修正系数k4。现行出水排放标准主要为一级A、一级B或者地方标准,基于此,该标准将出水排放标准划分为高于一级A、一级A和低于一级A三档,高于一级A又分为COD限值为40 mg∙L−1和COD限值小于等于30 mg∙L−1两档。出水排放标准是出水水质的区分,也是污水处理工艺的区分。当出水排放标准执行一级A或高于一级A时,必定会有深度处理单元,这会进一步增加污水处理厂的电耗、物耗,也会增加直接碳排放。因此,本标准规定出水排放标准修正系数k4主要用于间接碳排放强度的修正。

      5) 臭气控制程度修正系数k5。目前,部分污水处理厂增加了除臭设施设备,该部分主要会增加电耗。因此,臭气控制程度修正系数k5用于修正间接碳排放强度。无除臭指对污水处理厂各工艺单元产生的臭气未进行收集处理,部分除臭指对污水处理厂部分工艺单元的臭气进行收集处理,全部除臭指对全部工艺单元的臭气进行收集处理,包括加盖和地下式2种方式。

      (2) 碳排放修正强度计算

      该标准碳排放修正强度是基于总氮去除率修正系数、处理规模修正系数、耗氧污染物削减量修正系数、出水排放标准修正系数和臭气控制程度修正系数这5项修正系数对碳排放强度进行修正。

      式中:EP 为评价碳排放强度,kg∙m−3Eic 为间接碳排放修正强度,kg∙m−3Edc 为直接碳排放修正强度,kg∙m−3EN2O 为N2O直接碳排放强度,kg∙m−3k1 为总氮去除率修正系数,无量纲;ECH4为CH4直接碳排放强度,kg∙m−3ECO2 为CO2直接排放强度,kg∙m−3Ee 为电耗碳排放强度,kg∙m−3Eh 为热耗碳排放强度,kg∙m−3Ec 为物耗碳排放强度,kg∙m−3k2 为处理规模修正系数,无量纲;k3为耗氧污染物削减浓度修正系数,无量纲;k4 为出水排放标准修正系数,无量纲;k5为臭气控制程度修正系数,无量纲。

    • 该标准对污水处理厂低碳行为进行了界定,对开展污水处理设施设备低碳改造、全流程工艺单元的优化运行管理、低碳建设、温室气体监测与低碳运行核算等低碳行为进行加分鼓励。其中,设施设备主要体现在集约化、自动化、绿色高效等方面。优化运行则包括用电分区计量与评估、化学药剂优选与精准投加、生物处理系统优化调控。低碳建设包括采用污泥稳定化技术和清洁能源技术。温室气体监测与低碳运行核算包括污水处理厂开展重点温室气体 (CH4、N2O) 的现场监测并形成相关监测报告、实际碳排放核算并编制相关报告和低碳运行评价并形成年度报告。

    • 评价分数是碳排放修正强度分数和低碳行为鼓励分数两部分的加权之和。经专家组评议,考虑现阶段污水处理行业的低碳行为占污水处理厂碳减排比重,将碳排放修正强度分数权重值定为0.8,低碳行为鼓励分数权重值定为0.2。根据分级需要及污水处理厂低碳运行评价总分数,将污水处理厂低碳运行等级分为一级、二级和三级,分别代表污水处理厂低碳运行水平优秀、良好和一般。

    • 污水处理厂低碳运行评价流程包括资料收集、资料核查、数据核算和等级评定4个部分,如图1所示。根据运行数据,经过甄别、计算和修正得到评价碳排放强度分数。根据低碳行为资料,经过数据合适、现场核查、低碳行为认证得到低碳行为鼓励分数,最终得出评价总分数并进行等级评。监管层面的低碳行为认证由监管部门专门成立的机构进行材料认定,污水处理厂内部的评价由本厂专门负责低碳运行评价的部门认证。认证过程包括认证委托、文件评审、初始现场核查、认证结果评价与批准等。评价过程应保证数据的真实性、准确性与完整性。

    • 按照《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49—2022) 附录D表D.1、D.2和D.3要求,收集A、B、C污水处理厂2021年1月1日—2021年12月30日每日运行数据 (日平均值) ,收集台账详见表2表3。根据规范内公式计算得出污水处理厂低碳运行评价等级,如表4所示。

    • 污水处理厂的碳排放核算主要是依据IPCC排放因子法,而污水处理厂的低碳运行评价内容则是首次提出。评价标准制定过程主要是将不同的污水处理厂低碳运行水平受不同运行情况 (例如水量、进水水质和排放标准等) 进行类似归一化处理。低碳行为的鼓励是对污水处理厂低碳工作的定性评价指标,旨在对污水处理厂现有低碳工作的肯定,以及鼓励污水处理厂在后续设计、运行和改造过程中补充低碳行为,以获得更高的低碳等级。权重的比例对污水处理厂低碳运行评价结果影响较大,因此,该比例的确定由标准评审专家集体讨论最终确定。

      标准后续可完善的内容包括如下4点。1) 基于现有的IPCC排放因子法的样本数较少,未有针对我国的特定排放因子,各省也未根据本省情况制定温室气体排放因子。从行业的角度,化工行业也尚未对污水处理行业常用的大部分化学试剂排放因子进行确定。2) 基于IPCC排放因子法的计算方法具备较高的可操作性,除了未考虑不同地域、也未考虑不同处理工艺的影响,是污水处理厂未获得实测数据结果的替代方法。3) 污水处理厂的污泥处理处置方式包括外运、填埋、厌氧堆肥、热水解、脱水干化后焚烧、焚烧后作为建筑材料等,污泥处理处置情况不同导致的碳排放情况差异较大,目前也无相关标准可参考,因此,污水处理厂低碳运行评价不包括污泥处理处置的碳排放核算与评价。4) 根据低碳发展的需要,污水处理行业仍需完善一系列低碳标准,如污水处理行业低碳建设、污水处理厂温室气体 (N2O和CH4) 监测的标准和核算方法学、污水处理厂低碳管理标准以及报告要求等。

    • 《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49—2022) 作为我国首部污水处理领域低碳团体标准,对污水处理厂的低碳时代有开创性的意义。低碳运行评价是实现污水处理行业减污降碳的重要途径之一,是推动资源循环利用和低碳发展的重要措施。《污水处理厂低碳运行评价技术规范》 (T/CAEPI 49—2022) 规定了污水处理厂低碳运行评价的分级及其基本依据。该团体标准的制定、颁布和实施,对规范污水处理厂低碳运行评价工作,指导污水处理厂开展低碳工作,促进资源合理利用具有积极意义。今后需进一步做好该标准的宣贯工作,加强实施和减污降碳的落实推广工作,充分发挥标准的规范和引领作用。

    参考文献 (4)

返回顶部

目录

/

返回文章
返回