加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析

冯雨钦, 刘扬, 刘畅通, 刘泽华, 王佩, 张锦龙. 加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析[J]. 环境工程学报, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
引用本文: 冯雨钦, 刘扬, 刘畅通, 刘泽华, 王佩, 张锦龙. 加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析[J]. 环境工程学报, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
FENG Yuqin, LIU Yang, LIU Changtong, LIU Zehua, WANG Pei, ZHANG Jinlong. Effect analysis of FID field detection method for VOCs leakage in oil and gas recovery system of gas station[J]. Chinese Journal of Environmental Engineering, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
Citation: FENG Yuqin, LIU Yang, LIU Changtong, LIU Zehua, WANG Pei, ZHANG Jinlong. Effect analysis of FID field detection method for VOCs leakage in oil and gas recovery system of gas station[J]. Chinese Journal of Environmental Engineering, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124

加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析

    作者简介: 冯雨钦(1998—),男,硕士研究生,2787203695@qq.com
    通讯作者: 张锦龙(1977—),男,博士,教授,zjl@henu.edu.cn
  • 基金项目:
    国家自然科学基金面上项目(61675063,61975052);河南大学一流学科培育项目(2019YLZDCG02)
  • 中图分类号: X830.2

Effect analysis of FID field detection method for VOCs leakage in oil and gas recovery system of gas station

    Corresponding author: ZHANG Jinlong, zlj@henu.edu.cn
  • 摘要: 油气回收系统密闭点VOCs泄漏质量分数值是衡量加油站是否存在超标排放的重要指标。为提高加油站VOCs泄漏检测的时效性、代表性与准确性,采用FID现场检测方法对郑州市某加油站油气回收系统进行了检测,全方位对比分析了实验室气相色谱法与现场检测法的检测时效性、准确性,提出了密闭区域检测及质量保证和控制建议,并根据实际检测数据分析了易泄漏点。结果表明:采用FID现场检测方法对油气回收系统密闭点进行检测,能使检测成本降低90%,检测效率提高 15 倍;在现场检测前完成仪器的校准、响应时间的测定与精密度的验证工作,可使VOCs最大质量分数偏差维持在5%以下,这进一步验证了FID现场检测方法测量的准确度;油气回收系统泄漏点的确定及现场检测流程和步骤的优化,可有效提高检测数据的代表性;检测设备的定期校准,可确保FID示值相对误差在±10%范围内,响应时间不超过30 s,从而为检测质量控制提供保障;为确保泄漏点完好,结合实际检测工作,应采用液位仪自动计量技术,加强设备的维护保养并设置加油枪气液比为1.05~1.15。综上所述,在保证FID的准确性与稳定性的前提下,采用FID现场检测方法对油气回收系统VOCs泄漏质量分数进行检测具有时效性强、准确度高、数据代表性强等优势。本研究结果可为加油站采用FID现场检测油气回收系统VOCs泄漏的质量分数提供参考。
  • 磷是水体藻类生长所需的重要元素。随着工农业现代化的进程,大量污染物被直接排入江河湖泊,过量的磷元素导致水体富营养化,使得藻类生物过量繁殖产生水华,最终破坏水生态环境[1]。水环境中总磷的含量是衡量水体质量的重要指标之一。磷在水环境中主要以磷酸盐、无机磷和有机磷3种形式存在。其中,磷酸盐主要包括正磷酸盐(H3PO4H2PO4HPO24PO34)和聚磷酸盐等。目前,水体总磷的检测思路为,先通过强氧化剂消解[2]将水体中各种形态磷全部转化为正磷酸盐,再进行测量。

    我国环境水质总磷的标准检测方法主要是钼酸铵分光光度法[3]。因为测量时通常需要加温加压并添加化学试剂,所以若测量后生成的废弃试剂处理不当会造成人体伤害和环境污染等影响。其他检测方法还包括重力测定法和离子色谱法等[4-5],但这些方法操作流程复杂,响应时间慢,不适合水质连续自动监测和现场分析。近年来,电化学分析法逐渐被运用于测定无机磷酸盐含量[6]。其中,离子选择电极法因其具有操作简单、适合实时测量、环境友好、小型化、运行成本低等许多优点[7-8]引起了学者的广泛关注。然而,由于离子选择电极存在交叉敏感性,且容易受到工作环境影响,所以仍处于研究阶段,其电极检测精度和稳定性的改进成为当前研究的重点[9-12]

    金属钴被广泛应用于磷酸根离子选择电极的制备,但这类电极大多仅适用于酸性环境,且无法测定溶液中的总磷酸盐浓度。肖丹等[13]制备的钴棒电极在pH为4时,对H2PO4的响应斜率为50~56 mV·dec−1(dec为10倍摩尔浓度电化学标准单位),响应范围为10−5~10−2 mol·L−1,溶液中的溶解氧量和压力大小会对测定产生影响。XU等[14]在钴电极表面涂覆磷酸钴构筑磷酸根离子选择电极,在浓度为10−5~10−1 mol·L−1时,线性响应斜率为-39 mV·dec−1,测量pH范围为4.0~6.5,可保持性能稳定性,但电极制备过程的细微偏差会影响测定结果。

    本课题组前期采用金属钼离子选择电极测定磷酸根离子浓度[15]时发现,在浓度为10−5~10−1 mol·L−1HPO24溶液中,钼电极的响应电位与HPO24浓度呈现良好的线性关系和较好的选择性。常见的阴离子不会干扰电极对磷酸盐的测定。在pH=8.5时,检测斜率达到(-26.9±0.5) mV·dec−1,检出限为1.9×10−6 mol·L−1,响应时间小于60 s。钼电极制备简单,且具有较好的重复性和稳定性,可至少使用3个月。但在现场检测过程中,很难保证电极测量环境与电极标定环境完全一致,被测溶液pH变化存在不确定性,同时被测溶液温度变化也会使电极响应电位产生偏移,从而使电极检测精度受到影响。

    本研究综合分析溶液pH和被测溶液温度对电极测量的影响,通过磷酸根在不同pH条件下的分布系数,根据能斯特方程,采用最小二乘回归分析方法,建立补偿模型消除被测溶液pH和温度变化对电极输出电位的影响,以期为提高钼电极检测精度提供解决方案。

    离子选择电极(ion selective electrode,ISE)是一种分析溶液中特定离子浓度的电化学传感器。当离子选择电极浸入待测溶液中时,电极敏感膜与溶液在相界面上产生与待测离子活度有关的浓度差膜电势。该电位与待测离子含量之间满足能斯特(Nernst)方程[16],方程如式(1)所示。

    E=E0+2.303RTnFlgci=E0+Klgci (1)

    式中:E为某一浓度下的电极电势,mV;E0为电极标准电势,mV;R为气体常数(8.314 J·(K·mol)−1);T为热力学温度,K;F为法拉第常数(9.649×104 C·mol−1);n为参加反应的电荷数(带符号);ci为待测离子浓度;K为能斯特电位响应斜率。在pH和温度保持恒定的情况下,用最小二乘法估计E0K,可得电极响应电势与待测离子浓度对数之间的线性关系。

    以金属钼离子选择电极作为工作电极,Ag/AgCl电极作为参比电极,与被测溶液共同构成磷酸根离子浓度测量系统。通过建立标准磷酸根溶液浓度与电极响应电位之间的线性关系,测量钼电极的响应电位即可获得磷酸根离子(HPO24)的浓度。

    1) 被测溶液pH的影响。溶液中的溶质一般都属于电解质,根据电离程度的不同可分为强电解质和弱电解质。磷酸盐属于弱电解质,在水中有H3PO4H2PO4HPO24PO34这4种形态。各种形态含量所占比例随着溶液pH的不同而变化。在化学平衡体系中,通常用分布系数来表示某物质中某一形态的存在比例[17],并由此计算出特定条件下某种离子形态的浓度。对于三元酸H3PO4,其各存在形态的平衡浓度可用式(2)表示。

    cH3PO4=δH3PO4c=cH+3cH+3+Ka1cH+2+Ka1Ka2cH++Ka1Ka2Ka3ccH2PO4=δH2PO4c=Ka1cH+2cH+3+Ka1cH+2+Ka1Ka2cH++Ka1Ka2Ka3ccHPO42=δHPO42c=Ka1Ka2cH+cH+3+Ka1cH+2+Ka1Ka2cH++Ka1Ka2Ka3ccPO43=δPO43c=Ka1Ka2Ka3cH+3+Ka1cH+2+Ka1Ka2cH++Ka1Ka2Ka3c (2)

    式中:cH+=10pH,为溶液的酸度;cH3PO4cH2PO4cHPO42cPO43为对应磷酸根离子不同形态的平衡浓度;δH3PO4δH2PO4δHPO42δPO43为对应磷酸根离子不同形态的分布系数;Ka1Ka2Ka3分别表示H3PO4H2PO4HPO24在水中电离水解的平衡常数,分别为Ka1=6.9×103Ka2=6.2×108Ka3=4.8×1013[17]。因此,当溶液的pH已知时,将pH、Ka1Ka2Ka3的值代入式(3)可求得溶液中各离子形态的磷酸根分布系数,进一步可通过溶液磷酸盐总浓度及其各形态的分布系数求得溶液中磷酸盐各离子形态此时的平衡浓度。

    δH3PO4=(10pH)3(10pH)3+6.9×103×(10pH)2+4.278×1010×10pH+2.053×1022δH2PO4=6.9×103×(10pH)2(10pH)3+6.9×103×(10pH)2+4.278×1010×10pH+2.053×1022δHPO42=4.278×1010×10pH(10pH)3+6.9×103×(10pH)2+4.278×1010×10pH+2.053×1022δPO43=2.053×1022(10pH)3+6.9×103×(10pH)2+4.278×1010×10pH+2.053×1022 (3)

    图1显示了不同pH下磷酸盐各离子形态的具体分布情况。不同pH范围内磷酸盐的存在形态不同:当溶液pH<4时,溶质主要以H3PO4H2PO4存在;当溶液pH为4~10时,溶质主要以H2PO4HPO24存在;当pH>10时,溶质主要以HPO24PO34存在。在钼电极进行实际测定时,很难确保每次待测溶液的pH相同,则不同pH的被测溶液中H2PO4比例不相等,故将H2PO4的分布系数δHPO42引入能斯特方程,因此,有必要计算溶液中磷酸盐的总含量。

    图 1  磷酸根离子分布系数
    Figure 1.  Phosphate ion distribution coefficient

    在实际测定过程中,被测溶液pH的变化一方面会影响溶液中磷酸盐离子的形态分布,另一方面磷酸根离子选择电极对溶液中OH也会存在一定的电位响应,使得测量结果产生误差。因此,本研究考虑在Nernst方程中引入HPO24分布系数和pH线性补偿项来消除被测溶液pH变化对电极测量电位产生的干扰,由此建立基于金属钼的磷酸根离子选择电极测量模型,可用式(4)表示。

    E=EHPO24+K0pH=E0+Klg(ciδHPO24)+K0pH (4)

    式中:E0为电极标准电位,mV;K为电极对HPO24浓度的响应斜率,mV·dec−1δHPO24HPO24的分布系数;K0为电极对OH的响应斜率,mV·dec−1pH为溶液的pH。

    2) 溶液温度的影响。在磷酸根离子选择电极测量过程中,温度是影响电极测量准确性的重要因素之一。测量温度对电极的影响主要有2个方面:1) 对电极敏感膜产生影响,造成离子选择电极标准电位和参比电极电位的漂移;2) 会引起溶液离子浓度变化。由式(1)可知,温度变化时,离子选择电极检测斜率(能斯特响应斜率2.303RT/nF)与温度呈线性关系。

    在现场实测过程中,很难将电极保持在恒温条件下进行测定,因此,可通过建立相应补偿模型对能斯特测量模型进行改进,消除温度对电极测量的影响,从而得到磷酸根离子选择电极的温度校正模型。

    仪器:FE28-Standard型pH计(梅特勒-托利多仪器有限公司);218型Ag/AgCl参比电极(上海精密仪器有限公司);DA-968型超声波清洗仪(广东顺德灵通电子厂);DF-101S集热式磁力加热搅拌器(金坛市医疗仪器厂)。

    试剂:钼棒(99.99%,2 mm);磷酸氢二钠(Na2HPO4);氢氧化钠(NaOH);硫酸(H2SO4)。材料和试剂都购自国药集团化学试剂有限公司。所有测量溶液均用去离子水配制。

    先将金属钼棒(长约5 cm)的一端与铜线相连,用环氧树脂密封,再放在烘箱中烘干。另一端(工作面)用砂纸打磨成光滑表面,即可制得金属钼电极。制备的钼电极测量前无需预处理,只需在使用一段时间后在磨砂纸上用Al2O3粉末抛光,再用去离子水冲洗干净后,放乙醇和去离子水中超声波清理干净即可。

    装置结构如图2所示。装置由磷酸根离子选择电极测量系统、电极信号调理模块、pH计(包含温度测量)、A/D转换模块、数据接口和计算机组成。由钼电极作为工作电极,Ag/AgCl电极作为参比电极构成磷酸根离子选择电极测量系统,将其产生的响应信号经过前置放大器和信号调理电路,由A/D转换模块通过RS485转USB接口连接至计算机,实现对串口数据的采集、分析和存储。

    图 2  检测装置结构
    Figure 2.  Overall structure of detection device

    称取一定质量的Na2HPO4试剂,利用去离子水配制成浓度为10−6~10−1 mol·L−1的Na2HPO4标准溶液,调节被测溶液pH为7~12,经检测系统测得磷酸根离子电极响应电位值。依次改变溶液测量温度分别为5、15、25、35、40 ℃,测量电极响应电位。观测溶液pH和温度的变化对不同浓度磷酸根离子选择电极输出电位的影响,利用测量数据拟合建立磷酸根离子选择电极模型。

    在恒定温度25 ℃下,分别调节浓度为10−5、10−3、10−1 mol·L−1的Na2HPO4溶液pH,并测量电极输出电位,观测被测溶液pH变化对磷酸根电极响应电位的影响,结果如图3所示。在相同浓度磷酸根溶液下,电极的响应电位也随着pH的增大而增大,表明被测溶液pH变化直接影响钼电极的输出电位值。

    图 3  不同pH时钼电极的响应电位
    Figure 3.  Response potential of molybdenum electrode at different pHs

    图3的结果发现,在空白溶液中改变溶液pH测量电极输出电位,溶液pH和电极的响应电位变化近似呈线性关系。电极的响应电位随溶液pH的增大而提高,表明OH的存在会对电极测量造成干扰,影响电极测量精度。pH与电极响应电位的关系见式(5)。

    EOH=K0pH+Em (5)

    式中:EOH为电极的响应电位;K0为pH对电极的响应斜率;Em为电极的初始电位。根据式(5),利用图3中空白溶液测定数据进行线性拟合,得到pH对电极响应斜率K0为35.22 mV·dec−1。将K0值作为pH的线性补偿系数代入式(4),得到式(6)。

    E=E0+Klg(ciδHPO24)+35.22pH (6)

    进一步分析被测溶液温度变化对电极测量的影响,由于前期研究表明[15],钼电极在碱性条件下与HPO24发生响应,且当pH为11时,整体测量效果更佳。因此,取浓度为10−6~10−1 mol·L−1的Na2HPO4溶液,调节溶液pH为11,改变溶液温度依次为5、15、25、35、40 ℃,测定钼电极的响应电位,结果如图4所示。

    图 4  不同温度下钼电极的响应电位
    Figure 4.  Response potential of molybdenum electrode at different temperatures

    图4结果可知,温度的变化会引起钼电极输出电位的漂移。以25 ℃时的电势值为基准,温差增大,电位值变化幅度随之增大。利用式(6)以及图4中不同温度下10−6~10−1 mol·L−1Na2HPO4溶液的电极响应电位测定数据,运用最小二乘法分别拟合得到不同温度时的E0K,结果如图5所示。

    图 5  拟合参数随测量温度的变化
    Figure 5.  Fitting parameter changes with the measured temperature

    图5可发现,钼电极对HPO24浓度的响应斜率与标准电势会随着温度改变而改变,近似呈线性变化,假定温度与E0K的关系可用式(7)表示。

    {E0=aT+bK=cT+d (7)

    式中:E0为电极的标准电位,mV;KHPO24对电极响应电位的斜率,mV/dec;ac分别为电极标准电位和响应斜率随温度改变的变化系数;bd分别为电极标准电位和响应斜率的初始值。利用图5E0K随温度变化的关系作回归拟合,可得到a=2.129b=126.5c=0.1009d=23.92。将abcd的值代入式(7),得式(8)。

    {E0=2.129T+126.5K=0.1009T+23.92 (8)

    将式(8)代入式(6),得到基于金属钼的磷酸根离子选择电极的测定模型(式(9)),并将式(9)变形转化为式(10)。

    E=2.129T+126.5+(0.1009T+23.92)lg(ciδHPO24)+35.22pH (9)
    ci=10E(2.129T+126.5)35.22pH0.1009T+23.92δHPO24 (10)

    将式(3)中δHPO42代入式(10),可得到磷酸盐总浓度值与电极输出电位、溶液pH、温度之间的关系式(式(11))。

    ci=(10pH)3+6.9×103×(10pH)2+4.278×1010×10pH+2.053×10224.278×1010×10pH×10E(2.129T+126.5)35.22pH0.1009T+23.92 (11)

    式中:ci为磷酸根离子浓度,mol·L−1E为电极测量输出电位值,mV;pH为溶液的pH;T为温度,℃。

    为验证测定模型准确性,使用Na2HPO4试剂配制不同浓度的Na2HPO4溶液,改变溶液pH和温度,用磷酸根离子选择电极检测系统测定其响应电位,将所得数据代入式(11)计算出磷酸盐总浓度。比较离子浓度计算值与实际浓度值的相对误差,结果如表1所示。结果表明,该测量模型在10−6~10−1 mol·L−1的Na2HPO4溶液中测量误差最大为6.33%。

    表 1  准确率检验
    Table 1.  Accuracy test
    摩尔浓度/(mol·L−1)pH温度/℃输出电位/mV估计浓度/(mol·L−1)相对误差/%
    1.0×10−111.3428.35589.820×10−21.86
    1.0×10−210.8224.65071.020×10−21.78
    1.0×10−310.2719.24519.646×10−43.54
    1.0×10−49.7525.64189.725×10−52.75
    1.0×10−59.2032.43841.049×10−54.95
    1.0×10−68.9226.53381.063×10−66.33
     | Show Table
    DownLoad: CSV

    配制不同浓度的Na2HPO4溶液,使用该装置测定磷酸根离子含量,同时利用离子色谱法对这些溶液进行检测。为避免配制溶液过程中产生的系统误差,以离子色谱法检测结果作为溶液浓度真值,利用钼电极检测得到的结果及相对误差如表2所示。结果表明,本研究提出的计算方法与离子色谱法的测定结果间相对误差差值最大为5.50%,测定结果相近。因此,本研究建立的补偿模型可用于提高钼电极的检测精度。

    表 2  本方法与离子色谱法检测结果对比
    Table 2.  Detection results comparison between this method and ion chromatography
    质量浓度/(mg∙L−1)电化学方法/(mg∙L−1)离子色谱法/(mg∙L−1)绝对误差/(mg∙L−1)相对误差/%
    5.005.125 55.029 00.096 51.92
    1.000.975 70.986 30.010 61.07
    0.500.526 80.511 40.015 43.01
    0.100.103 60.098 20.005 45.50
    0.050.047 70.049 40.001 73.44
    0.010.010 70.010 30.000 43.88
     | Show Table
    DownLoad: CSV

    1)利用离子选择电极法进行溶液磷酸根离子含量测定过程中,被测溶液pH和环境温度的变化会引起电极响应电位的漂移、电极线性斜率的变化,对测量结果产生误差。

    2)在能斯特方程的基础上,通过引入HPO24分布系数、pH的线性补偿项及温度校正模块建立基于金属钼的磷酸根离子选择电极的测量模型,以消除测量过程中溶液pH值和温度的改变对测量结果的影响。建立的测量模型10−6~10−1 mol·L−1的Na2HPO4溶液中对磷酸根离子含量的测量误差最大为6.33%,大大提高了磷酸根离子选择电极的检测精度。

    3)采用离子选择电极法检测操作简单,建立测量模型有利于进一步实现水环境中磷酸根离子含量的在线实时监测,为环境水质总磷的自动化监测提供参考。

  • 图 1  闸阀检测位置

    Figure 1.  Detection position of gate valve

    图 2  法兰和连接件检测位置

    Figure 2.  Detection position of flange and connector

    图 3  油气回收真空泵检测位置

    Figure 3.  Detection position of oil and gas recovery vacuum pump

    图 4  密闭区域不同时间点FID检测值曲线

    Figure 4.  Curve of FID detection values at different time points in closed area

    表 1  郑州市某加油站仪器校准相对误差

    Table 1.  Relative error of instrument calibration in a gas station in Zhengzhou

    气体测量值/(μmol∙mol−1)标准气体值/(μmol∙mol−1)相对误差/%
    第1次第2次第3次
    零气00000
    标准气体1500.8499.8490.9500.7−0.7
    标准气体21 987.21 980.11 975.01 990.1−0.5
    标准气体39 952.19 933.69 914.79 998.5−0.6
      注:零气为VOCs质量分数<10−5 μmol·mol−1(以甲烷计)的清洁空气;示值误差小于10%,说明仪器满足标准要求。
    气体测量值/(μmol∙mol−1)标准气体值/(μmol∙mol−1)相对误差/%
    第1次第2次第3次
    零气00000
    标准气体1500.8499.8490.9500.7−0.7
    标准气体21 987.21 980.11 975.01 990.1−0.5
    标准气体39 952.19 933.69 914.79 998.5−0.6
      注:零气为VOCs质量分数<10−5 μmol·mol−1(以甲烷计)的清洁空气;示值误差小于10%,说明仪器满足标准要求。
    下载: 导出CSV

    表 2  精密度质量分数检测数据

    Table 2.  Precision for mass fraction detection data

    检测次数样品1质量分数/(μmol∙mol−1)样品2质量分数/(μmol∙mol−1)
    标准值检测值标准值检测值
    1500.7510.49 998.510 012.1
    2500.7508.19 998.59 994.7
    3500.7511.79 998.510 035.9
    4500.7503.99 998.59 998.2
    5500.7509.39 998.510 028.4
    6500.7502.69 998.510 016.6
    检测次数样品1质量分数/(μmol∙mol−1)样品2质量分数/(μmol∙mol−1)
    标准值检测值标准值检测值
    1500.7510.49 998.510 012.1
    2500.7508.19 998.59 994.7
    3500.7511.79 998.510 035.9
    4500.7503.99 998.59 998.2
    5500.7509.39 998.510 028.4
    6500.7502.69 998.510 016.6
    下载: 导出CSV

    表 3  加油站油气回收系统密闭点VOCs泄漏质量分数检测结果

    Table 3.  VOCs leakage mass fraction detection result at sealing points of oil and gas recovery system in gas stations

    采样区域泄漏点FID现场检测泄漏质量分数/(μmol∙mol−1)实验室检测泄漏质量分数/(μmol∙mol−1)偏差/%
    检测值1检测值2检测值3检测值4最大值样品1样品2样品3样品4最大值
    加油区1#枪油气回收铜管连接口33.637.632.332.337.632.535.230.331.335.26.4
    加油区1#枪油气回收检测口2.03.01.92.43.01.52.31.32.22.323.3
    加油区1#枪油气回收管线弯头208.1209.2227.1226.5227.1203.8205.9223.2221.4223.21.7
    加油区2#枪油气回收铜管连接口0.30.40.30.40.40.20.30.20.30.325.0
    加油区2#枪油气回收检测口0.20.20.20.20.20.20.20.20.20.20
    加油区2#枪油气回收管线弯头209.1229.2217.9207.1229.1203.8221.2214.3202.4221.23.4
    储油区油气回收接口0.50.50.40.30.50.50.50.30.30.50
    储油区1#卸油口1.61.41.71.41.71.51.1.61.41.65.9
    储油区2#卸油口0.30.30.20.20.20.20.20.20.20.20
    储油区1#罐量油口181.2172.3174.9179.6181.2178.3168.1172.4172.7178.31.6
    储油区1#罐量油口法兰1356.3345.4342.1359.9359.9353.4342.3332.1356.1356.11.1
    储油区1#罐量油口法兰2379.3371.4379.8374.4379.8378.2368.3379.2372.8379.20.2
    储油区2#罐量油口201.4203.1197.9201.4203.1197.7200.8197.3199.1200.81.1
    储油区2#罐量油口法兰1325.2327.9326.8329.2329.2322.8325.7318.3326.9326.90.7
    储油区2#罐量油口法兰2378.1379.2379.9377.4379.9375.8376.2376.1368.8376.21.0
    采样区域泄漏点FID现场检测泄漏质量分数/(μmol∙mol−1)实验室检测泄漏质量分数/(μmol∙mol−1)偏差/%
    检测值1检测值2检测值3检测值4最大值样品1样品2样品3样品4最大值
    加油区1#枪油气回收铜管连接口33.637.632.332.337.632.535.230.331.335.26.4
    加油区1#枪油气回收检测口2.03.01.92.43.01.52.31.32.22.323.3
    加油区1#枪油气回收管线弯头208.1209.2227.1226.5227.1203.8205.9223.2221.4223.21.7
    加油区2#枪油气回收铜管连接口0.30.40.30.40.40.20.30.20.30.325.0
    加油区2#枪油气回收检测口0.20.20.20.20.20.20.20.20.20.20
    加油区2#枪油气回收管线弯头209.1229.2217.9207.1229.1203.8221.2214.3202.4221.23.4
    储油区油气回收接口0.50.50.40.30.50.50.50.30.30.50
    储油区1#卸油口1.61.41.71.41.71.51.1.61.41.65.9
    储油区2#卸油口0.30.30.20.20.20.20.20.20.20.20
    储油区1#罐量油口181.2172.3174.9179.6181.2178.3168.1172.4172.7178.31.6
    储油区1#罐量油口法兰1356.3345.4342.1359.9359.9353.4342.3332.1356.1356.11.1
    储油区1#罐量油口法兰2379.3371.4379.8374.4379.8378.2368.3379.2372.8379.20.2
    储油区2#罐量油口201.4203.1197.9201.4203.1197.7200.8197.3199.1200.81.1
    储油区2#罐量油口法兰1325.2327.9326.8329.2329.2322.8325.7318.3326.9326.90.7
    储油区2#罐量油口法兰2378.1379.2379.9377.4379.9375.8376.2376.1368.8376.21.0
    下载: 导出CSV
  • [1] 《中国化学工业年鉴》编辑部. 中国化学工业年鉴2017-2018[M]. 北京: 中国化工信息中心, 2019.
    [2] SIGUT M, ALAYON S, HERNANDEZ E. Applying pattern classification techniques to the early detection of fuel leaks in petrol stations[J]. Journal of Cleaner Production, 2014, 80(1): 262-270.
    [3] 何玉荟, 支国强, 李田富. 加油站油气回收技术研究[J]. 环境工程, 2016, 34(S1): 905-909.
    [4] THOMPSON A M, BALASHOV N V, WITTE J C, et al. Tropospheric ozone increases over the southern Africa region: Bellwether for rapid growth in Southern Hemisphere pollution[J]. Atmospheric Chemistry and Physics, 2014, 14(18): 9855-9869. doi: 10.5194/acp-14-9855-2014
    [5] SHAO M, LU S, LIU Y, et al. Volatile organic compounds measured in summer in Beijing and their role in ground-level ozone formation[J]. Journal of Geophysical Research:Atmospheres, 2009, 114(D2): D00G06.
    [6] ZHANG Q, YUAN B, SHAO M, et al. Variations of ground-level O3 and its precursors in Beijing in summertime between 2005 and 2011[J]. Atmospheric Chemistry and Physics, 2014, 14(12): 6089-6101. doi: 10.5194/acp-14-6089-2014
    [7] 蔡乐天, 许潇锋, 许纯领, 等. 宿迁市VOCs污染特征和来源解析[J]. 环境科学学报, 2021, 41(11): 4341-4352.
    [8] 陈天雷, 吴敏, 潘成珂, 等. 基于前体物多情景排放的兰州市2030年夏季臭氧预测[J/OL]. (2021-10-27)[2022-01-10]. 环境科学. https://doi.org/10.13227/j.hjkx.202108116.
    [9] 陈雪, 黄晓锋, 朱波, 等. 深圳市秋季VOCs空间分布特征与关键减排物种[J]. 中国环境科学, 2021, 41(9): 4069-4076. doi: 10.3969/j.issn.1000-6923.2021.09.012
    [10] STOJIĆ A, STOJIĆ S S, ŠOŠTARIĆ A, et al. Characterization of VOC sources in an urban area based on PTR-MS measurements and receptor modelling[J]. Environmental Science and Pollution Research, 2015, 22(17): 13137-13152. doi: 10.1007/s11356-015-4540-5
    [11] United States Environmental Protection Agency. Clean air act[S]. Washington DC: US EPA, 2013.
    [12] 王思宇, 黄玉虎, 胡玮, 等. 加油站油气处理装置作用及VOCs排放现状[J]. 环境科学研究, 2021, 34(2): 279-285.
    [13] 沈旻嘉, 郝吉明, 王丽涛. 中国加油站VOC排放污染现状及控制[J]. 环境科学, 2006, 27(8): 1473-1478. doi: 10.3321/j.issn:0250-3301.2006.08.001
    [14] 中华人民共和国生态环境部. 工业企业挥发性有机物泄漏检测与修复技术指南: HJ 1230-2021[S]. 北京: 生态环境部环境标准研究所, 2021.
    [15] 王继钦, 陈军辉, 韩丽, 等. 四川省加油站挥发性有机物排放及控制现状[J]. 环境污染与防治, 2020, 42(6): 672-677.
    [16] 朱诗月, 赵朝成, 韩丰磊. 石化企业VOCs排放检测方法及影响因素研究[J]. 化学工业与工程, 2019, 36(4): 7-17.
    [17] 中华人民共和国国家环境保护总局, 中华人民共和国国家质量监督检疫总局. 加油站大气污染物排放标准: GB 20952-2007[S]. 北京: 中国环境科学出版社, 2007.
    [18] 中华人民共和国生态环境部, 中华人民共和国国家市场监督管理总局. 加油站大气污染物排放标准: GB 20952-2020[S]. 北京: 中国环境出版集团, 2020.
    [19] LUONG J, HUA Y, GRAS R, et al. In-situ methanation with flame ionization detection for the determination of carbon dioxide in various matrices[J]. Analytical Methods, 2018, 10(10): 1275-1279. doi: 10.1039/C8AY00079D
    [20] 高少华, 邹兵, 崔积山, 等. 基于氢火焰离子化检测仪响应因子的设备泄漏排放核算[J]. 化工环保, 2017, 37(6): 707-712. doi: 10.3969/j.issn.1006-1878.2017.06.020
    [21] 中华人民共和国环境保护部. 泄漏和敞开液面排放的挥发性有机物检测技术导则: HJ 733-2014[S]. 北京: 中国环境科学出版社, 2014.
  • 加载中
    Created with Highcharts 5.0.7访问量Chart context menu近一年内文章摘要浏览量、全文浏览量、PDF下载量统计信息摘要浏览量全文浏览量PDF下载量2024-062024-072024-082024-092024-102024-112024-122025-012025-022025-032025-042025-050Highcharts.com
    Created with Highcharts 5.0.7Chart context menu访问类别分布DOWNLOAD: 2.8 %DOWNLOAD: 2.8 %HTML全文: 93.1 %HTML全文: 93.1 %摘要: 4.1 %摘要: 4.1 %DOWNLOADHTML全文摘要Highcharts.com
    Created with Highcharts 5.0.7Chart context menu访问地区分布其他: 96.6 %其他: 96.6 %XX: 1.4 %XX: 1.4 %上海: 0.0 %上海: 0.0 %东莞: 0.0 %东莞: 0.0 %丽水: 0.0 %丽水: 0.0 %保定: 0.0 %保定: 0.0 %内网IP: 0.0 %内网IP: 0.0 %北京: 1.0 %北京: 1.0 %南通: 0.0 %南通: 0.0 %台州: 0.0 %台州: 0.0 %合肥: 0.0 %合肥: 0.0 %宁波: 0.1 %宁波: 0.1 %张家口: 0.0 %张家口: 0.0 %德阳: 0.0 %德阳: 0.0 %惠州: 0.0 %惠州: 0.0 %成都: 0.0 %成都: 0.0 %无锡: 0.0 %无锡: 0.0 %武汉: 0.1 %武汉: 0.1 %济南: 0.0 %济南: 0.0 %深圳: 0.0 %深圳: 0.0 %牡丹江: 0.0 %牡丹江: 0.0 %福州: 0.0 %福州: 0.0 %聊城: 0.0 %聊城: 0.0 %西宁: 0.0 %西宁: 0.0 %西安: 0.1 %西安: 0.1 %重庆: 0.0 %重庆: 0.0 %其他XX上海东莞丽水保定内网IP北京南通台州合肥宁波张家口德阳惠州成都无锡武汉济南深圳牡丹江福州聊城西宁西安重庆Highcharts.com
图( 4) 表( 3)
计量
  • 文章访问数:  6392
  • HTML全文浏览数:  6392
  • PDF下载数:  86
  • 施引文献:  0
出版历程
  • 收稿日期:  2022-01-20
  • 录用日期:  2022-03-31
  • 刊出日期:  2022-05-10
冯雨钦, 刘扬, 刘畅通, 刘泽华, 王佩, 张锦龙. 加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析[J]. 环境工程学报, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
引用本文: 冯雨钦, 刘扬, 刘畅通, 刘泽华, 王佩, 张锦龙. 加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析[J]. 环境工程学报, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
FENG Yuqin, LIU Yang, LIU Changtong, LIU Zehua, WANG Pei, ZHANG Jinlong. Effect analysis of FID field detection method for VOCs leakage in oil and gas recovery system of gas station[J]. Chinese Journal of Environmental Engineering, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124
Citation: FENG Yuqin, LIU Yang, LIU Changtong, LIU Zehua, WANG Pei, ZHANG Jinlong. Effect analysis of FID field detection method for VOCs leakage in oil and gas recovery system of gas station[J]. Chinese Journal of Environmental Engineering, 2022, 16(5): 1748-1756. doi: 10.12030/j.cjee.202201124

加油站油气回收系统VOCs泄漏FID现场检测方法及效果分析

    通讯作者: 张锦龙(1977—),男,博士,教授,zjl@henu.edu.cn
    作者简介: 冯雨钦(1998—),男,硕士研究生,2787203695@qq.com
  • 河南大学物理与电子学院,开封 475004
基金项目:
国家自然科学基金面上项目(61675063,61975052);河南大学一流学科培育项目(2019YLZDCG02)

摘要: 油气回收系统密闭点VOCs泄漏质量分数值是衡量加油站是否存在超标排放的重要指标。为提高加油站VOCs泄漏检测的时效性、代表性与准确性,采用FID现场检测方法对郑州市某加油站油气回收系统进行了检测,全方位对比分析了实验室气相色谱法与现场检测法的检测时效性、准确性,提出了密闭区域检测及质量保证和控制建议,并根据实际检测数据分析了易泄漏点。结果表明:采用FID现场检测方法对油气回收系统密闭点进行检测,能使检测成本降低90%,检测效率提高 15 倍;在现场检测前完成仪器的校准、响应时间的测定与精密度的验证工作,可使VOCs最大质量分数偏差维持在5%以下,这进一步验证了FID现场检测方法测量的准确度;油气回收系统泄漏点的确定及现场检测流程和步骤的优化,可有效提高检测数据的代表性;检测设备的定期校准,可确保FID示值相对误差在±10%范围内,响应时间不超过30 s,从而为检测质量控制提供保障;为确保泄漏点完好,结合实际检测工作,应采用液位仪自动计量技术,加强设备的维护保养并设置加油枪气液比为1.05~1.15。综上所述,在保证FID的准确性与稳定性的前提下,采用FID现场检测方法对油气回收系统VOCs泄漏质量分数进行检测具有时效性强、准确度高、数据代表性强等优势。本研究结果可为加油站采用FID现场检测油气回收系统VOCs泄漏的质量分数提供参考。

English Abstract

  • 随着我国成品油消费数量急剧上升,加油站数量也不断增加。据统计,中国加油站数量已经超过了1.2×105[1]。加油站经营的汽油在运输、储存和销售过程中产生的油气[2],主要以沸点120 ℃以下的烷烃、烯烃、苯系物等碳氢类有机化合物为主,其中包含很多致癌物质,对人体及周边环境危害较大[3]。作为PM2.5与O3的重要前体物,烃类VOCs具有较强的挥发性[4-7]。VOCs的强活性特征决定了在条件合适的情况下会有光化学反应发生,氮氧化物在反应中可与VOCs结合产生臭氧[4,8-10]。因此,VOCs的检测是加油站空气污染防控的重要内容之一。

    在20世纪70年代,美国相关企业就开展了对油气回收技术的研究[3]。1990年,美国联邦政府出台了相关法令,要求空气质量不达标区域的加油站须加装油气回收系统[11]。目前,全球环保领域公司研发的油气回收系统对加油站油气排放抑制的作用显著,为减少油罐及其附属设施的无组织排放发挥了重要作用[12]。为减少油气排放产生的VOCs对周边环境造成影响,我国自2016年前后开始要求加油站进行油气回收改造,并要求加油站定期对油气回收系统进行密闭性、液阻和气液比进行检测。为进一步减少加油站经营过程中的油气排放,我国新版《加油站大气污染物排放标准》(GB 20952-2020)中增加了油气回收系统密闭点位油气泄漏质量分数的检测项目,并要求在营加油站从2022年1月1日开始执行。

    加油站挥发性有机物排放超标的主要原因是油气回收系统密闭点位存在损坏、泄漏等问题[13]。因此,如何及时、准确地发现超标排放的密闭点位置就显得尤为重要。中华人民共和国生态环境部组织编制的《工业企业挥发性有机物泄漏检测与修复技术指南》对加油站油气回收系统定期检测与修复提供了指导 [14] 。目前,加油站VOCs泄漏质量分数检测通常采用聚乙烯氟化物(PVF)气袋或苏玛罐对加油站油气回收系统密闭点进行取样并送入实验室,在实验室中采用气相色谱仪检测加油站油气回收系统密闭点油气泄漏质量分数,进而对加油站油气泄漏情况做出分析判断[15-16]。这种方法虽然可以对加油站VOCs的泄漏质量分数进行精准检测,但由于此方法操作步骤较为繁琐,并且要求取样48 h内完成检测,取样人员需要频繁地送样品到实验室,综合成本较高;同时气袋采样无法保证样品的代表性,无法及时有效地找出加油站油气回收系统超标排放的密闭点。

    2021年,生态环境部和国家市场监督管理总局联合发布了《加油站大气污染物排放标准》(GB 20952-2020)并以此标准替代GB 20952-2007。在该标准中,对油气回收系统密闭点位油气泄漏质量分数值做出了明确要求。该标准要求任何时间段检测值均应≤500 μmol·mol−1,一旦在政府环保部门的检查中发现加油站密闭点油气泄漏质量分数值超标,加油站会遭受经济或行政处罚[17-18]。如何有效提高对油气回收系统油气泄漏质量分数检测数据的时效性、代表性与准确性成为亟待研究解决的课题。采用便携式氢火焰离子化检测仪(FID)检测油气泄漏质量分数,可以实现现场实时检测,具有检测效率高、数据代表性强、成本低等优势,成为加油站油气回收系统密闭点位油气泄漏质量分数检测的首选方法。

    为提高检测效率并保证检测数据具有代表性,本研究在分析油气回收系统结构与已有检测仪器原理的基础上,提出一种既能保证检测数据准确性及代表性,又能有效提高检测效率并能准确找出超标排放密闭点位置的现场检测方法;探讨现场检测方法与实验室气相色谱法的区别;梳理现场检测的准备工作流程并对检测的对比结果进行讨论;分析现场检测的时效性和代表性、数据的准确性及质量保证和控制效果。本研究结果可为加油站采用FID现场检测油气回收系统VOCs泄漏气体提供参考。

    • 本研究采用便携式氢火焰离子化检测仪(FID)检测油气泄漏质量分数。FID是以氢气与空气燃烧生成的火焰为能源,使有机物发生化学电离,并在电场作用下产生电信号来进行检测[19-20]。当载气携带被测组分从色谱柱流出后,与氢气按照一定的比例混合,一起从喷嘴喷出,并在喷嘴周围空气中燃烧;以燃烧所产生的高温(约2 100 ℃)火焰为能源,被测组分在火焰中被电离成正离子和负离子,在极化电压形成的电场作用下,正负离子分别向负极和正极移动,形成离子流。离子流强度很小,一般为10−8 A,这些微电流经过微电流放大器放大后被记录下来,信号的大小在一定范围内与单位时间内进入检测器的被测组分的质量成正比,从而测定出被测物的质量分数。

    • 检测人员到达加油站现场接受加油站入场安全培训后,开始勘察加油站油气回收系统工艺线路,确定需要检测的密闭点,并将密闭点的名称和照片录入到防爆手持终端,对各个点位进行唯一性编号;建档完成后,就可以开展现场检测。具体操作要求:检测前做好风向风速判定、设备状态判定、设备校准;检测时及时将检测数据上传;检测后应检查设备漂移;当发现泄漏点超标时,及时通知加油站维修;修复后进行复测,复测合格后出具检测结果报告。此外,加油站油气回收系统密闭点泄漏质量分数检测还需要遵循以下几个方面的要求。

      1)检测仪器的性能要求。现场使用的便携式氢火焰离子化检测仪必须满足以下几项要求:FID经过有校准资质的检定机构校准合格后方可使用;FID的量程应能满足加油站油气排放质量分数限值的测定要求,分辨率应保证质量分数限值的±2.5%范围内可读;FID校准时示值相对误差必须在±10%范围内,响应时间不应超过30 s;FID必须通过防爆安全检验认证。

      2)检测人员的要求。现场检测人员一般由2名取得油气回收项目资格证书的检验员组成,1人检测,1人复核。检测人员穿戴防静电工作服,严格执行加油站各项安全规定。

      3)检测点的选取要求。通过对加油站油气回收系统结构的分析,可以得到容易产生泄漏的部位,主要包括人工量油口端盖、卸油口、油气回收口盖帽、集液罐管口、加油机油气回收管和阀门处、真空泵、排放管压力/真空阀(关闭状态时)、与油气处理装置连接的管道连接法兰、阀门等部位,同时还要检测在卸油过程中与油罐车连接的接口、管道等密闭点位。

      4) FID仪器的操作要求。为保证检测数据的代表性,检测时将FID检测探头放置于确定好的密闭点周围,并沿其外围以小于10 cms−1的速度移动,同时关注仪器读数。如果发现读数上升,放慢检测探头移动速度直至测得最大读数,并在最大读数处停住,停留时间约为仪器响应时间的2 倍,记录最大读数。

      5)泄漏点状态的稳定性要求。加油站的一些密闭区域,由于长期的油气聚集,油气质量分数往往很高,故检测时须提前打开密封盖板通风,检测时才能真实反映密闭点位的泄漏质量分数值。

    • 1) FID使用前的校准。为提高加油站油气回收系统密闭点油气泄漏质量分数检测的准确度,每次检测前需要对氢火焰离子化检测仪进行校准。校准时,使用零气(VOCs质量分数<10−5 μmol·mol−1(以甲烷计)的清洁空气)和3组标准气体(甲烷)完成对仪器示值相对误差的测定。其中,测得的仪器示值相对误差必须在±10%范围内。

      在仪器预热和零气校准后,向FID检测探头通入校准参考化合物标准气体(甲烷)。待仪器读数稳定后,按标准值来调节仪器读数。如果仪器读数无法调整到合适的质量分数值,表明仪器有故障,在使用前应予以排除。进行多点校准,标准质量分数限值均应在校准值的范围之内。

      反复3次测定零气和同一质量分数的校准参考化合物标准气体(甲烷),仪器示值相对误差的计算方法见式(1)。

      式中:D为仪器示值相对误差;ci为仪器 i 次测量的示值平均值;cs为校准参考化合物标准气体质量分数值,μmol∙mol−1。依据《泄漏和敞开液面排放的挥发性有机物检测技术导则》(HJ 733-2014)[21]的规定,当仪器示值相对误差在±10%范围内时,检测仪器准确度才能满足要求。

      2) 响应时间的测定。检测前,还需要对FID响应时间进行测定。响应时间是指FID测定VOCs泄漏质量分数时,从仪器读数开始变化到仪器最终显示稳定读数的 90%所需要的时间。依据《泄漏和敞开液面排放的挥发性有机物检测技术导则》(HJ 733-2014)[21]的规定,FID响应时间应不超过30 s。

      在测定响应时间的过程中,使用数值为1 990 μmol∙mol−1的标准气体,检测人员使用机械秒表记录测定时间。检测时,将检测泵、检测探头和过滤装置安装调整到位,从检测探头口通入零气,待氢火焰离子化检测仪读数稳定后,迅速切换通入校准气体,记录人员观察记录仪器达到最终稳定显示读数的 90%(1 791 μmol∙mol−1)所需要的时间。重复进行3次上述操作,取平均值作为该仪器的响应时间。

      3) 检测点位的选择。检测点位的选择对于检测数据的准确性以及确定油气回收系统超标排放密封点位置至关重要。检测点包括阀门、法兰及其他连接件、油气回收真空泵、开口阀和开口管线4部分。

      ①阀门。阀门是加油站最常见的设备,加油站油气回收系统阀门通常检测的部位包括阀杆与填料压盖之间的密封、填料压盖或压板与阀盖之间的密封、阀盖与阀体之间的密封和其他可能泄漏VOCs的部位。具体检测部位如图1所示。检测人员首先将检测探头置于阀杆填料压盖处,沿其界面周围移动进行检测;然后将检测探头置于填料压盖下的法兰连接部位,在其外围移动进行检测;最后对阀体可能发生泄漏的其它连接界面进行检测。

      ②法兰及其他连接件。现场检测人员在检测时,应将检测探头置于法兰垫圈处,沿其外围移动进行检测,检测探头应尽可能插入两法兰之间的缝隙进行检测。如果检测探头直径超过缝隙宽度,则应将检测探头紧贴两法兰之间的缝隙,并与密封边缘垂直。连接件(螺纹接头)检测探头同样应与密封边缘垂直,并与管线走向呈30°~60°。对于活接头,接头两侧都应检测。法兰和连接件检测位置见图2

      ③油气回收真空泵。加油站油气回收真空泵是转动设备,转动密封部位容易泄漏油气,因此,检测人员应在泵轴杆和密封界面处来回移动检测探头进行检测。如果是旋转轴,检测探头放置在离轴杆密封界面1 cm内进行检测;如果由于其构造的外形原因而无法完整地对阀杆周围进行检测,则应对所有可以检测的部位进行检测。对真空泵可能发生油气泄漏的所有连接处都应进行检测,具体检测位置如图3所示。

      ④开口阀和开口管线。加油站开口阀和开口管线主要包括人工计量口端盖、卸油口、集液罐管口、排放管压力/真空阀以及在卸油过程中与油罐车连接的接口等部位,现场检测人员须将检测探头置于其开口处与空气接触区域的中心部位进行检测。

    • 为验证检测数据的准确性与重复性,对所选取的郑州市某加油站现场1#、2#油气回收系统15个密闭点位进行了检测并完成仪器校准和响应时间的测定。通过现场勘查后,确定加油站油气回收系统需要检测的密闭点位,即可进行密闭点位泄漏质量分数的检测工作。

    • 首先,对实验所用仪器进行校准。FID显示的最大示值相对误差为-0.7%,满足技术导则要求,校准误差结果如表1所示。

      其次,对该加油站使用的FID检测仪响应时间进行3次测定。响应时间分别为10、12和14 s。仪器响应平均时间为12 s,满足技术导则的要求。

      第三,对密闭点油气质量分数进行检测。在FID满足技术导则的要求后,对该加油站油气回收系统密闭点位油气泄漏质量分数进行检测。现场检测时应将加油机下部盖板、量油作业区的人孔盖、卸油区的盖板及罐区操作井盖板提前打开,保证密闭区域聚集的油气通过自然通风扩散,否则,检测质量分数会偏高且数据显示不稳定,缺乏代表性。图4反映了打开密封区域盖板后不同时间段FID的检测值趋势。

      第四,对仪器精密度进行验证。通过检测甲烷标准气体验证FID的精密度。实验中甲烷标准气体质量分数分别为500.7 μmol∙mol−1和9 998.5 μmol∙mol−1,同一操作人员分别连续进行6次重复测量。据表2数据计算出了相对标准偏差RSD。计算结果表明,本次实验的相对标准偏差分别为0.69%、0.16%,远远小于10%。

    • FID现场检测法和实验室气相色谱检测法原理相似,不同点在于检测的时效性不同。FID检测可以在加油站现场实时完成;而实验室气相色谱法需要现场取样后,送到实验室分析才可以得到泄漏质量分数值。

      为进一步验证2种方法测量准确度与检测效率,对选定的密闭点采用气袋法采样并送实验室进行了检测。检测时,检测人员使用PVF气袋在每个密闭点的不同部位取4个样品,共取样品60个,取样用时约3 h。取样后,立即将样品送实验室并使用气相色谱仪进行检测,检测用时约3 h。同时使用FID在相同密闭点的4个不同部位进行现场检测。具体检测数据见表3

      表3可以看出,与实验室气相色谱法相比,采用现场检测方法所测量的不同密封点VOCs泄漏质量分数最大值偏差在5%以下,最大值偏差大的密封点位主要是泄漏质量分数值很低的检测点,远远低于排放限值,且2种方法反映的质量分数值基本一致。

    • 表3还可以看出,加油站油气回收系统容易发生泄漏的部位包括真空泵附近的油气回收管线弯头、量油口及其下部的法兰等密闭点,其检测质量分数值均>100 μmol∙mol−1。由油气回收的工作原理可知,与油气回收系统相连接的储罐内一直处于微正压,密闭点的密封性是预防泄漏质量分数超标的重要环节。对于自吸式加油机,在其下部同时安装有自吸泵、计量器和真空泵等转动设备,运转时产生的振动,会造成通过丝扣连接的油气回收管线弯头密闭点产生松动,易引起泄漏质量分数超标。在加油站日常经营过程中,为监控油品损溢,计量员每天需要打开量油口量取储罐内油品的液位。由于打开阀门时单向施力的作用,长期积累会造成量油口下部的法兰连接螺栓松动并容易引起这些密闭点泄漏质量分数超标。加油枪气液比是加油站油气回收系统最关键的参数,如果设置不合理,会造成储罐内油气压力增高,也容易引起密闭点泄漏质量分数超标。

      为确保加油站油气回收系统易泄漏密闭点的密封性完好,加油站应采取以下防范措施:在油罐上设置液位仪,取代人工计量,可以最大限度地降低量油口的打开频次;设备管理人员应定期对加油机下部的设备进行维护保养,避免振动超标;每月使用铜扳手对真空泵附近的丝扣连接和量油口附近的法兰连接螺栓进行紧固;对量油口球阀定期维护保养,避免阀门打开时施力过大;结合实际检测工作,合理设置气液比,建议设置在1.05~1.15。

    • 采用现场取样送实验室检测的方法,依据有关取样规范要求,取样数量为120~200个,单站取样时间约1 d,取样完成后送回实验室检测及数据处理时间约2 d,完成1座加油站的检测需要3 d左右。采用FID现场检测时,仅需1名人员检测,另1名人员监督复核。通过防爆手持数据终端直接记录检测数据,方便检测数据的溯源。通过数据接口将检测数据导入已编制好的检测报告模板中,从而快速生成检测报告,缩短了编制时间。按照检测质量控制要求,每天开始检测前,检测人员需要对FID进行标准气体校准,一般用时为 20 min左右,每站现场检测需要1 h左右,每天大约可以检测5座加油站,检测效率是前者的15 倍左右。检测成本的核算主要包括参与的检测人员、交通运输、检测仪器和耗材等费用,采用现场取样送实验室检测的单站费用为5 000~6 000元,而采用现场检测法可以随密闭性、气液比和液阻3项指标一起进行,单站费用仅需要500元左右,费用是前者的1/10,可以极大地降低检测成本。所以,采用FID检测加油站油气回收系统VOCs泄漏质量分数效率高、成本低、时效性强。

    • 表1可以看出,现场实验所使用的FID最大示值相对误差为-0.7%,标准气体校准相对误差远低于《泄漏和敞开液面排放的挥发性有机物检测技术导则》(HJ 733-2014)规定的限值。FID响应时间均优于前述技术导则的要求。根据表2数据计算出的FID2种不同标准气体检测的相对标准偏差RSD,分别为0.69%和0.16%,RSD值远远小于10%。所以,采用FID现场检测法能够满足密闭点VOCs质量分数检测准确度的要求。

      为进一步说明现场FID检测方法得到的数据与目前通用的气袋现场采样后送实验室检测方法在精度上无明显下降,在该加油站油气回收系统的关键点进行采样,得到的数据见表3。通过对比可以看出,采用现场检测方法对比现场取样后送检方法,最大质量分数偏差绝对值基本在5%以下。

    • 图4可以看出,加油机量油口聚集了较大质量分数的油气,当盖板打开后,随着时间的推移,油气快速扩散,7 min左右FID显示值趋于稳定,基本能够显示密闭区域内密闭点的泄漏状态。所以,为保证检测数据的代表性,降低检测时所带来的随机误差与系统误差,检测人员在密闭区域检测时,应提前打开密闭区域内的盖板,以便聚集的油气扩散后再开始检测。

    • 便携式FID属于移动检测设备,仪器工作环境无法达到实验室的环境条件,并且经常放置到机动车上,随道路的起伏而颠簸,因此,保证仪器的准确性及稳定性显得尤为重要。为做好检测质量保证和控制,FID在出库、入库时,检测人员和设备管理人员应共同检查设备是否完好,校准证书是否在有效期内,并使用零气和标准气体进行校准,一旦发现示值误差超过最大允许误差,检测人员应当对存在疑问的检测项目重新安排复测。检测人员使用FID现场检测时,每天检测前应使用零气和标准气体进行仪器校准,仪器示值误差必须小于10%,一旦发现超差,需要查找原因,并对前1 d的检测项目进行复测。现场检测时采样探头在待测设备外围移动不能过快,避免漏掉最高质量分数点。变换待测源时,在下一个待测源检测开始前,检测人员应确定FID是否处于待测状态。

    • 1) 采用现场检测方法对油气回收系统密闭点进行检测对比现场采样后送实验室检测,检测成本可降低90%,检测效率可提高15倍左右,同时通过对关键点位的检测可以及时在现场排查出超标排放的密闭点位置,有利于及时进行维修。

      2) 检测前完成仪器的校准、响应时间的测定与精密度的验证工作,可使加油站油气回收系统密闭点VOCs最大质量分数偏差维持在5%以下。

      3) 为保证检测质量与准确度,并确保FID现场检测示值相对误差在±10%范围内,须对检测设备的定期校准,检测仪器响应时间不超过30 s。

      4) 容易发生泄漏的位置主要来自于真空泵附近的油气回收管线弯头、量油口及其下部的法兰等密闭点,可通过采取液位仪自动计量技术、加强设备的维护保养和合理设置加油枪的气液比等有效防范措施,确保易泄漏点的密封完好。