厌氧动态膜生物反应器中动态膜形成及其运行周期的影响因素分析

程刚, 朱雷, 许颖, 黄霞. 厌氧动态膜生物反应器中动态膜形成及其运行周期的影响因素分析[J]. 环境工程学报, 2018, 12(5): 1408-1415. doi: 10.12030/j.cjee.201710155
引用本文: 程刚, 朱雷, 许颖, 黄霞. 厌氧动态膜生物反应器中动态膜形成及其运行周期的影响因素分析[J]. 环境工程学报, 2018, 12(5): 1408-1415. doi: 10.12030/j.cjee.201710155
CHENG Gang, ZHU Lei, XU Ying, HUANG Xia. Analysis on factors influencing formation of dynamic membrane and operational cycle in anaerobic dynamic membrane bioreactor[J]. Chinese Journal of Environmental Engineering, 2018, 12(5): 1408-1415. doi: 10.12030/j.cjee.201710155
Citation: CHENG Gang, ZHU Lei, XU Ying, HUANG Xia. Analysis on factors influencing formation of dynamic membrane and operational cycle in anaerobic dynamic membrane bioreactor[J]. Chinese Journal of Environmental Engineering, 2018, 12(5): 1408-1415. doi: 10.12030/j.cjee.201710155

厌氧动态膜生物反应器中动态膜形成及其运行周期的影响因素分析

  • 基金项目:

    科技部国际科技创新合作重点专项(2016YFE0118500)

Analysis on factors influencing formation of dynamic membrane and operational cycle in anaerobic dynamic membrane bioreactor

  • Fund Project:
  • 摘要: 为探究影响厌氧动态膜生物反应器(AnDMBR)稳定运行的因素,选用不锈钢网为基材构建AnDMBR并用于处理生活污水,着重考察了不锈钢网孔径(200、300 和500目)、混合液污泥浓度及膜通量对AnDMBR成膜及运行周期的影响。结果表明:不锈钢网的目数越大,动态膜形成越快,但运行周期较短;低污泥浓度成膜时间较慢,但运行周期较长;污泥胞外多聚物(EPS)对动态膜的形成及运行周期影响较大,EPS越高,动态膜形成越快,但动态膜堵塞越严重;高通量更容易导致动态膜堵塞。选用300 目的不锈钢网,在污泥浓度为2 000 mg·L-1,通量为32 L·(m2·h)-1的条件下开展的连续实验表明,AnDMBR稳定运行周期可达240 h。清洗实验结果表明离线清洗方式更适用于动态膜的清除。
  • 加载中
  • [1] .HUANG X, XIAO K, SHEN Y X.Recent advances in membrane bioreactor technology for wastewater treatment in China[J].Frontiers of Environmental Science & Engineering in China,2010,4(3):245-271
    [2] .OZGUN H, DERELI R K, ERSAHIN M E, et al.A review of anaerobic membrane bioreactors for municipal wastewater treatment:Integration options,limitations and expectations[J].Separation and Purification Technology,2013,118:89-104 10.1016/j.seppur.2013.06.036
    [3] .SKOUTERIS G, HERMOSILLA D, LOPEZ P R, et al.Anaerobic membrane bioreactors for wastewater treatment: A review[J].Chemical Engineering Journal,2012,198:138-148 10.1016/j.cej.2012.05.070
    [4] .IORHEMEN O T, HAMZA R A, TAY J H.Membrane bioreactor (MBR) technology for wastewater treatment and reclamation: Membrane fouling[J].Membranes,2016,6(2):33-62 10.3390/membranes6020033
    [5] .YU Z, DONG B.Recent advances in dynamic membrane bio-reactor[C]// IEEE.International Symposium on Water Resource and Environmental Protection,2011:1283-1286
    [6] . 唐虹,康得军,匡帅,等. 胞外聚合物提取方法的研究进展[J]. 市政技术,2016,34(5):162-166
    [7] . 袁栋栋,樊耀波,徐国良,等. 膜生物反应器中临界通量理论的研究[J]. 膜科学与技术,2010,30(2):97-103
    [8] .ZHANG X, WANG Z, WU Z, et al.Membrane fouling in an anaerobic dynamic membrane bioreactor (AnDMBR) for municipal wastewater treatment:Characteristics of membrane foulants and bulk sludge[J].Process Biochemistry,2011,46(8):1538-1544 10.1016/j.procbio.2011.04.002
    [9] .CHU H, ZHANG Y, ZHOU X, et al.Dynamic membrane bioreactor for wastewater treatment: Operation, critical flux, and dynamic membrane structure[J].Journal of Membrane Science,2014,450:265-271 10.1016/j.memsci.2013.08.045
    [10] .LIANG S, QU L, MENG F, et al.Effect of sludge properties on the filtration characteristics of self-forming dynamic membranes (SFDMs) in aerobic bioreactors: Formation time, filtration resistance, and fouling propensity[J].Journal of Membrane Science,2013,436:186-194 10.1016/j.memsci.2013.02.021
    [11] .YU H, WANG Z, WU Z, et al.Dynamic membrane formation in anaerobic dynamic membrane bioreactors:Role of extracellular polymeric substances[J].Plos One,2015,10(10):e0139703 10.1371/journal.pone.0139703
  • 加载中
计量
  • 文章访问数:  2587
  • HTML全文浏览数:  2295
  • PDF下载数:  404
  • 施引文献:  0
出版历程
  • 刊出日期:  2018-05-19

厌氧动态膜生物反应器中动态膜形成及其运行周期的影响因素分析

  • 1. 武汉科技大学城市建设学院,武汉 430070
  • 2. 清华大学环境学院环境模拟与污染控制国家重点联合实验室,北京 100084
基金项目:

科技部国际科技创新合作重点专项(2016YFE0118500)

摘要: 为探究影响厌氧动态膜生物反应器(AnDMBR)稳定运行的因素,选用不锈钢网为基材构建AnDMBR并用于处理生活污水,着重考察了不锈钢网孔径(200、300 和500目)、混合液污泥浓度及膜通量对AnDMBR成膜及运行周期的影响。结果表明:不锈钢网的目数越大,动态膜形成越快,但运行周期较短;低污泥浓度成膜时间较慢,但运行周期较长;污泥胞外多聚物(EPS)对动态膜的形成及运行周期影响较大,EPS越高,动态膜形成越快,但动态膜堵塞越严重;高通量更容易导致动态膜堵塞。选用300 目的不锈钢网,在污泥浓度为2 000 mg·L-1,通量为32 L·(m2·h)-1的条件下开展的连续实验表明,AnDMBR稳定运行周期可达240 h。清洗实验结果表明离线清洗方式更适用于动态膜的清除。

English Abstract

参考文献 (11)

目录

/

返回文章
返回