  • 摘要: 应用CFD软件对某电厂电除尘器进口矩形烟道内气流分布进行数值模拟。结果表明:电除尘器原进口矩形烟道监测截面的气流分布极其不均匀,数值模拟结果与实验结果速度分布趋势比较吻合。基于此,通过多次改变电除尘器进口矩形烟道内导流板的数量、位置、尺寸等结构参数,使得改造后烟道监测截面风量偏差降到了±2.2%,气流分布相对均方根值均小于0.2,气流分布较为均匀。
  • 加载中
  • 加载中
计量
  • 文章访问数:  1996
  • HTML全文浏览数:  729
  • PDF下载数:  678
  • 施引文献:  0
出版历程
  • 收稿日期:  2010-03-18

电除尘器进口矩形烟道气流分布改进的CFD模拟

  • 1. 浙江省电力试验研究院,杭州 310014
基金项目:

摘要: 应用CFD软件对某电厂电除尘器进口矩形烟道内气流分布进行数值模拟。结果表明:电除尘器原进口矩形烟道监测截面的气流分布极其不均匀,数值模拟结果与实验结果速度分布趋势比较吻合。基于此,通过多次改变电除尘器进口矩形烟道内导流板的数量、位置、尺寸等结构参数,使得改造后烟道监测截面风量偏差降到了±2.2%,气流分布相对均方根值均小于0.2,气流分布较为均匀。