Loading [MathJax]/jax/output/HTML-CSS/jax.js

基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估

陈铁, 孙飞云, 杨淑芳, 陈立春, 熊向陨, 汪燕. 基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估[J]. 环境工程学报, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
引用本文: 陈铁, 孙飞云, 杨淑芳, 陈立春, 熊向陨, 汪燕. 基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估[J]. 环境工程学报, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
CHEN Tie, SUN Feiyun, YANG Shufang, CHEN Lichun, XIONG Xiangyun, WANG Yan. Load quantification and effect evaluation of urban non-point source pollution in the Guanlan river basin based on SWAT model[J]. Chinese Journal of Environmental Engineering, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
Citation: CHEN Tie, SUN Feiyun, YANG Shufang, CHEN Lichun, XIONG Xiangyun, WANG Yan. Load quantification and effect evaluation of urban non-point source pollution in the Guanlan river basin based on SWAT model[J]. Chinese Journal of Environmental Engineering, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108

基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估

    作者简介: 陈铁(1994—),男,硕士研究生。研究方向:面源污染、海绵城市。E-mail:chentie_anywhere@qq.com
    通讯作者: 孙飞云(1982—),男,博士,副教授。研究方向:膜处理、海绵城市等。E-mail:sun_fy@hit.edu.cn
  • 基金项目:
    深圳市技术攻关项目(JSGG20170414101900541);深圳市基础研究项目(JCYJ20160406162038258)
  • 中图分类号: X502

Load quantification and effect evaluation of urban non-point source pollution in the Guanlan river basin based on SWAT model

    Corresponding author: SUN Feiyun, sun_fy@hit.edu.cn
  • 摘要: 随着我国城市区域污水收集、截污系统的完善与水质净化厂出水标准的提高,点源污染逐步得到控制,城市面源污染对河流水质的影响越来越凸显。针对当前城市内河流集水区域城市面源污染负荷难以量化、对水体水质影响效应难以解析等问题,以深圳市观澜河流域为研究对象,通过对流域的现场勘察调研与地表累积物采样研究,来修正流域土地利用类型数据与SWAT模型的城镇数据库,构建流域城市面源污染评价模型。结果表明:SWAT模型城镇数据库中地表沉积物最大累积量(DIRTMX)、地表沉积物中总氮含量(TNCONC)、地表灰尘累积半饱和时长(TNALF)与地表灰尘总磷含量(TPCONC)对TN与TP负荷的模拟最为敏感;建立的SWAT模型对观澜河流域径流量、TP与TN模拟验证期的纳什效率系数(ENS)分别为0.79、0.7、0.67,决定系数(R2)分别为0.81、0.77、0.81,模型拟合结果较好。应用SWAT模型分析了2018年观澜河流域TN和TP的城市面源污染时空分布特征:TN和TP输出最高值为13.31~14.91 t·km−2和1.69~1.86 t·km−2;8月份观澜河流域降雨径流污染最为严重,TN和TP负荷分别为2.15 t·km−2与0.24 t·km−2。上述评估结果可为区域城市面源污染的负荷量化与影响效应评估提供参考。
  • 焦化废水是焦化、煤气化和焦化副产物回收过程中产生的一类典型工业废水,主要来自于炼焦过程中产生的剩余氨水、冷却水及其他污水[1],组分复杂,污染物浓度高、毒性大、易发生诱变和致癌[2-3]。焦化废水一般经氨汽提和溶剂萃取预处理后进一步进行生物处理[4-5],然而生化出水COD仍为200~300 mg·L−1[6],难于达到相关排放标准[7],需要进一步深度处理[8]

    常见的深度处理技术有臭氧氧化、光催化氧化和Fenton氧化等。Fenton氧化方法在实际的废水深度处理中最为常用,主要通过H2O2/Fe2+在酸性条件下产生 · OH,以降解污染物[9]。然而H2O2利用率低,存在投药量大、反应效率差等缺点[10]。为此,近年来探索了许多类芬顿技术,如光芬顿法[11-12]利用与亚铁离子协同催化H2O2的方式提高处理效果,但反应太阳能利用率低,能耗大;电芬顿法[11, 13]利用O2在电解池阴极产生的H2O2与亚铁离子反应,生成 · OH和Fe3+,但阴极材料电流效率低,H2O2产量不高。为此,以Fenton反应为基础的相关处理技术仍在研究中,如微波与Fenton、Fe-EDTA的联合等[12, 14],在研究中发现,这些类芬顿技术可以针对性地克服常规Fenton存在的反应效率低等问题,以达到更有效的处理效果。

    微波是一种超高频电磁波(0.3~300 GHz),为避免干扰雷达和电信频率,用于工业和民用的频率分别为915 MHz和2 450 MHz,其中915 MHz的微波穿透深度要高于2 450 MHz近3倍[15]。当微波辐射与Fenton联用时,由于微波穿透性强,能直接加热反应物分子,降低反应的活化能和分子的化学键强度,因此,可显著提高Fenton反应活性,从而降低Fenton反应时间、增强反应效率[16]。陈艳芳等[17]采用微波诱导Fenton降解水中对硝基氯苯,对硝基氯苯和COD的去除率分别可达98.9%和90.8%;李硕等[18]采用微波强化Fenton方法降解了水中的BPA,发现可减少H2O2和Fe2+的投加量,促进 · OH的生成。但微波强化Fenton反应对于不同实际废水的处理效果及其对应的反应机理有待于进一步的研究。

    本研究以焦化废水的生化出水作为研究对象,探讨了利用微波强化Fenton处理的效果和应用的可行性。在优化且确定Fenton反应条件的基础上,对同等实验条件下微波强化Fenton反应与Fenton反应的处理效果进行了比较,并初步探讨了在微波引入后Fenton处理效果显著提升的可能机理,可为目前我国焦化废水处理和达标排放处理技术的选择提供参考。

    实验水样取自内蒙古乌海某焦化厂生化出水(原水)。该厂采用A/O二级处理方法,水样取回后置于4 ℃保存。水样pH为8.4±0.2,COD为(203±5) mg·L−1,TOC为(34.0±2.0) mg·L−1,氨氮为(4.45±0.3) mg·L−1,总氮为(83.6±2.3) mg·L−1,色度为836±43。

    实验所使用的FeSO4·7H2O,30% H2O2,NaOH,98% H2SO4等均为分析纯,购自国药集团化学试剂有限公司。

    首先对Fenton氧化的处理效果进行评价,相关药剂投量的比例参考文献中的方法[19]进行优化。采用批量实验的方式进行,分别取200 mL生化出水水样于5个烧杯中,用3 mol·L−1的H2SO4溶液调节pH至3,加入Fe2+1.9 mmol·L−1,分别按照摩尔比1∶2,1∶4,1∶6,1∶9,1∶10投加量加入H2O2。置于多位磁力搅拌器(WH-410D,德国Wiggens公司)上搅拌反应78 min,调节pH至7,终止Fenton反应。将反应后的焦化废水置于数显恒温水浴锅(LUX-12,北京陆希科技有限公司)内,在50 ℃下加热30 min,以去除残留的H2O2[20]

    实验中采用的微波反应体发射频率为915 MHz,装机功率为5 kW,实用功率为0.9~1.1,采用半批量运行的方式进行实验。将实验用水用3 mol·L−1 H2SO4溶液调节pH至3,同时加入一定浓度的Fe2+和H2O2 (分别为1.9 mmol·L−1和15.6 mmol·L−1),在微波反应体内开启电磁辐照,反应18 min,之后进入深度反应池慢速搅拌60 min,采集相关样品进行分析。

    测定TOC和色度所用水样均过0.45 μm滤膜。分别对样品COD (NOVA 60,德国MERCK)、TOC (TOC-Vcph,日本岛津)、色度(LICO 620,美国HACH)和pH (AS600,日本ASONE)等指标进行测定;使用荧光分光光度计(F-7000,日本日立)测定三维荧光光谱。

    用滤纸过滤100 mL混匀的Fenton反应出水及微波-Fenton反应出水,将滤纸放入电热恒温鼓风干燥箱(DGG-9070B,上海森信),在105 ℃条件下烘干1 h,置于干燥皿中,冷却后测定反应产生的污泥量。

    取混匀的Fenton反应出水及微波-Fenton反应出水静置沉淀30 min,在转速为1 200 r·min−1的条件下离心6 min,将上清液倒出,用冷冻干燥机(FD-1A-50,北京博医康实验仪器有限公司)于−80 ℃进行冷冻干燥[21],然后用红外光谱仪(Nicolet iZ10,美国赛默飞世尔)测定铁泥的红外光谱。

    Fenton反应主要通过氧化作用和混凝作用来去除污染物,影响因素包括pH、Fe2+浓度和H2O2的浓度。为考察不同H2O2投加量对Fenton反应的影响效果,本实验在pH为3,Fe2+为1.9 mmol·L−1的条件下,分别按1∶2,1∶4,1∶6,1∶9,1∶10摩尔比投加H2O2,反应时间为78 min。图1为在不同H2O2投加量条件下,Fenton反应对废水的处理效果。由图1可知,随着H2O2投加量的增加,反应对有机物(以COD和TOC计)的去除呈现先增大后减小的趋势。 · OH是Fenton反应中氧化去除有机污染物的主要活性氧化物种,其生成量受Fe2+和H2O2的影响[22-23]。当H2O2投加过量时,H2O2会与生成的 · OH发生进一步的反应,从而降低其氧化作用[24];同时,H2O2能将Fe2+氧化为Fe3+,阻碍氧化反应的进行,降低了 · OH的生成量[25]。因此,在Fenton反应过程中,Fe2+和H2O2的投加比例对于处理效果有着重要影响。从色度处理效果来看,较低H2O2投加量(3.6 mmol·L−1)下,即可达到一定的处理效果,SUVA的变化趋势与色度相一致,说明导致色度的多为芳香类的化学物质[26],此类物质相对容易氧化去除。在Fe2+浓度为1.9 mmol·L−1、H2O2为15.6 mmol·L−1的条件下,可对COD和TOC达到最优的去除效果,其去除率分别为18%和39%。后续的相关实验均在此条件下开展。

    图 1  不同H2O2投加量条件下Fenton反应对COD、TOC、色度和SUVA的去除效果影响
    Figure 1.  Effect of Fenton reaction on removal of COD, TOC, chroma and SUVA at different H2O2 dosages

    为探讨微波强化Fenton反应的处理效果和稳定性,在pH=3,Fe2+和H2O2的浓度分别为1.9 mmol·L−1和15.6 mmol·L−1的条件下,进行了连续7 d的实验,其中电磁辐照18 min,深度反应池慢速搅拌1 h进行反应。图2为连续运行7 d后微波强化Fenton反应前后TOC、COD以及色度的变化结果。与Fenton处理效果相比,加入微波处理后的效果显著提升,对于COD的去除率从18%左右提升至75%左右,TOC从40%左右提升至65%左右,且去除效果稳定,COD出水稳定在80 mg·L−1以下,达到了《炼焦化学工业污染物排放标准》 (GB 16171-2012)中直接排放的要求。色度的芳香类物质虽相对容易氧化去除,但与Fenton处理效果相比,仍有一定的提升。另外,在实验过程中,限于条件的限制,未对相关微波参数(辐射时间等)等进行优化,后续将进一步针对相关条件和影响因素进行研究确认。

    图 2  微波-Fenton处理前后COD、TOC和色度变化
    Figure 2.  Variations of COD, TOC and chroma before and after microwave-enhanced Fenton treatment

    图3为原水及经过Fenton和微波强化Fenton处理后的三维荧光光谱图。溶解性有机物的荧光光谱可分为5类[27]:芳香类蛋白质(Ex为200~250 nm,Em为280~330 nm);芳香类蛋白质(Ex为220~250 nm,Em为330~380 nm);富里酸(Ex为220~250 nm,Em为380~480 nm);微生物渗滤液(Ex为250~280 nm,Em为280~380 nm);胡敏酸(Ex为250~400 nm,Em为380~480 nm)。由图3可知,与原水相比,Fenton反应出水中残留的溶解有机物主要为胡敏酸和微生物渗滤液类物质,而经微波-Fenton处理后出水的荧光强度极微弱,仅有较弱的微生物渗滤液类物质的荧光信号,这表明多数有机物已被氧化去除。

    图 3  实验用水及不同反应出水后的三维荧光光谱图
    Figure 3.  EEM of raw water in the experiments and effluents after different reactions

    氧化及吸附是Fenton反应去除污染物的主要过程。为进一步比较Fenton及电磁强化Fenton处理的效果,对反应出水过滤(0.45 μm滤膜)前后的COD进行了比较测定,结果见图4。由图4可知,Fenton反应出水的COD为182 mg·L−1,去除率较低(18%),但过膜后的COD为61 mg·L−1,其去除率可达到72%,这表明大部分COD可吸附在泥相中;而微波强化Fenton反应后的出水COD为52 mg·L−1,对COD的去除效率达到77%,过滤后的出水COD为42 mg·L−1,这表明大部分有机物被氧化去除。图5反映了在2种处理方式下,过滤后所得泥相中吸附的COD量,微波强化Fenton和Fenton反应产生的干泥量分别为1.27 g·L−1和1.34 g·L−1,泥相中COD吸附量分别为8.07 mg·g−1和85.73 mg·g−1。由此可见,Fenton反应出水中的过滤物中吸附了大量COD,而对于微波强化Fenton处理来说,有机物的去除主要依靠氧化进行,降低了泥相中COD的残留量。由此可知,微波强化Fenton反应可显著提高Fenton反应的氧化能力。从反应机理上来说,微波具有的热效应能使极性分子产生高速旋转碰撞,从而改变体系的热力学函数,降低反应的活化能和分子的化学键强度[28]。另外,微波的非热效应能振荡微波场中的极性分子,使其化学键断裂[29-31],从而提高了Fenton反应的氧化能力。

    图 4  不同反应类型COD的氧化量和吸附量
    Figure 4.  Oxidation and adsorption of COD in different reaction types
    图 5  不同反应出水的含泥量及吸附量结果
    Figure 5.  Sludge content and adsorption amounts in the effluents after different reactions

    图6为过滤物(铁泥)的红外光谱图。由图6可见,2种反应体系中铁泥有明显较宽的O—H伸缩振动谱带,吸收峰为3 540~2 715 cm−1,表明含有COOH、醇或苯酚中O—H的吸收峰。在2 965~2 850 cm−1处,存在微弱的CH3反对称伸缩振动吸收峰与烷烃CH2反对称和对称伸缩振动吸收峰。在2 500~1 900 cm−1处,有一较强的吸收峰,这是C≡C和C≡N伸缩振动以及C=C=C、C=C=O等累积双键不对称伸缩振动。2种反应出水在(1 600±10) cm−1、1 500~1 450 cm−1处存在明显的芳环C=C伸缩振动,这说明芳香烃类化合物的存在。在1 135 cm−1附近出现较强的硫氢C=S伸缩振动吸收峰。2种反应中出水铁泥所含物质基本相同,大致是芳香族和硫氢化合物,不同之处在于,Fenton反应中铁泥在625 cm−1附近出现硫氢C—S伸缩振动吸收峰,这进一步说明微波-Fenton反应能直接氧化去除含C—S键的物质,而Fenton反应则是通过吸附在铁泥中将其去除[32-33]

    图 6  微波-Fenton和Fenton体系中铁泥的红外光谱图谱
    Figure 6.  Fourier transform infrared spectroscopy of iron sludge samples in microwave-enhanced Fenton and Fenton systems

    1)微波强化Fenton可显著提升焦化废水生化出水中有机物的去除效果。同一实验条件下,微波强化Fenton处理后COD的去除率相比Fenton处理后COD的去除率提升59%,出水COD稳定在80 mg·L−1以下,满足《炼焦化学工业污染物排放标准》要求。三维荧光结果表明,多数有机物已被氧化去除。

    2)氧化是微波强化Fenton处理过程中有机物去除的主要机理,可能与微波辐射通过热效应或非热效应加快羟基自由基的生成、氧化反应效率的提高有关。Fenton处理后泥相中的吸附对于有机物的去除有重要贡献。红外分析结果表明,吸附作用对象主要是芳香族和硫氢化合物。

    3)微波强化Fenton方法是焦化废水达标排放的一种可供选择的技术,后续将对相关反应条件、特征污染物的去除以及工艺适用性开展进一步的研究和优化。

  • 图 1  观澜河流域水系分布

    Figure 1.  Distribution of water systems in the Guanlan River Basin

    图 2  地表灰尘采样区域分布

    Figure 2.  Distribution of land surface dust sampling area

    图 3  所收集到的原始空间数据及其处理后的数据

    Figure 3.  Original spatial data collected and its processed data

    图 4  观澜河流域城市用地类型地表沉积物监测的研究结果

    Figure 4.  Research results of land surface sediment monitoring of urban land use types in Guanlan river basin

    图 5  研究区域参数敏感性分析结果

    Figure 5.  Parameter sensitivity analysis results of study region

    图 6  SWAT模型对径流量、TN与TP的模拟

    Figure 6.  Simulation of monthly runoff, TN and TP by SWAT model

    图 7  2018年观澜河流域TN与TP单位面积的面源污染年输出负荷空间分布特征

    Figure 7.  Spatial distribution characteristics of annual output loads of non-point source pollution of TN and TP per unit area in Guanlan river basin in 2018

    图 8  2018年观澜河流域六类功能区面源污染负荷贡献率

    Figure 8.  Contribution ratio of nonpoint pollution load of six urban land use types in Guanlan river basin in 2018

    图 9  2018年观澜河流域城市面源污染对水体TN与TP的贡献率

    Figure 9.  Contribution rate of urban nonpoint pollution to TN and TP of water body in Guanlan river basin in 2018

    表 1  SWAT模型城镇数据库参数

    Table 1.  Parameters of urban land use database of SWAT model

    序号参数名称含义
    1URBNAME字型代码,当添加新的城市用地类型时,其4位字符代码必须唯一
    2FIMP不透水区域占城市土地类型总区域的分数,包括直接与间接有水力联系的不透水区域
    3FCIMP有水力联系的不透水区域占城镇土地类型总区域的分数
    4CURBDEN城镇土地类型中街边石的长度密度
    5URBCOEF去除不透水区域地表沉积物的冲刷系数
    6DIRTMX不透水区域沿单位长度街边石的地表沉积物最大累积量
    7THALF不透水区域地表沉积物从0累积到1/2 DIRTMX所需的时间
    8TNCONC不透水区域地表沉积物中总氮含量
    9TPCONC不透水区域地表沉积物中总磷含量
    10TNO3CONC不透水区域地表沉积物中总硝酸盐含量
    11URBCN2城镇土地类型水分条件Ⅱ下不透水区域的SCS径流曲线系数CN值
    序号参数名称含义
    1URBNAME字型代码,当添加新的城市用地类型时,其4位字符代码必须唯一
    2FIMP不透水区域占城市土地类型总区域的分数,包括直接与间接有水力联系的不透水区域
    3FCIMP有水力联系的不透水区域占城镇土地类型总区域的分数
    4CURBDEN城镇土地类型中街边石的长度密度
    5URBCOEF去除不透水区域地表沉积物的冲刷系数
    6DIRTMX不透水区域沿单位长度街边石的地表沉积物最大累积量
    7THALF不透水区域地表沉积物从0累积到1/2 DIRTMX所需的时间
    8TNCONC不透水区域地表沉积物中总氮含量
    9TPCONC不透水区域地表沉积物中总磷含量
    10TNO3CONC不透水区域地表沉积物中总硝酸盐含量
    11URBCN2城镇土地类型水分条件Ⅱ下不透水区域的SCS径流曲线系数CN值
    下载: 导出CSV

    表 2  SWAT模型构建所需数据来源及基本信息

    Table 2.  Required data sources and basic information for SWAT model building

    数据类型名称来源说明
    空间数据流域地形数据水经注软件(付费)分辨率为10 m DEM栅格数据
    流域土地利用类型数据中科院地理研究所资源环境数据云平台1 km × 1 km土地利用/覆被矢量数据
    流域土壤类型分布数据中科院地理研究所资源环境数据云平台1∶1 000 000土壤类型矢量数据
    地表观测数据气象数据中国气象数据网、深圳气象局2000—2018年气象要素日变化数据
    点源数据深圳市环境监测中心2018年污水厂尾水水量、水质日变化数据
    控制断面水量、水质数据深圳市环境监测中心2014—2018年企坪断面水量、水质日实测数据
    土壤属性数据中国土壤数据库、SPAW软件、参数计算公式等[7]更新模型土壤属性数据库
    城镇用地类型属性数据现场监测研究、文献等更新模型城镇属性数据库
    数据类型名称来源说明
    空间数据流域地形数据水经注软件(付费)分辨率为10 m DEM栅格数据
    流域土地利用类型数据中科院地理研究所资源环境数据云平台1 km × 1 km土地利用/覆被矢量数据
    流域土壤类型分布数据中科院地理研究所资源环境数据云平台1∶1 000 000土壤类型矢量数据
    地表观测数据气象数据中国气象数据网、深圳气象局2000—2018年气象要素日变化数据
    点源数据深圳市环境监测中心2018年污水厂尾水水量、水质日变化数据
    控制断面水量、水质数据深圳市环境监测中心2014—2018年企坪断面水量、水质日实测数据
    土壤属性数据中国土壤数据库、SPAW软件、参数计算公式等[7]更新模型土壤属性数据库
    城镇用地类型属性数据现场监测研究、文献等更新模型城镇属性数据库
    下载: 导出CSV

    表 3  观澜河流域SWAT模型城镇数据库关键参数初始数值

    Table 3.  Initial values for key parameters of urban database of SWAT model for Guanlan river basin

    用地类型FIMPFCIMPCURBDEN/(km·km−2)URBCOEF/mm−1DIRTMX/(kg·km−1)THALF/dTNCONC/(g·kg−1)TNO3CONC/(g·kg−1)TPCONC/(g·kg−1)URBCN2
    商业用地0.940.83260.138.191.6030.033.710.3098
    工业用地0.760.72150.1312.862.3541.463.800.5098
    高密住宅0.920.81340.1310.840.7581.549.170.6598
    中密住宅0.570.49300.1321.690.7521.401.790.2198
    交通道路0.900.90130.139.373.9038.804.480.3498
    公管用地0.440.35200.136.043.9017.801.720.1898
    用地类型FIMPFCIMPCURBDEN/(km·km−2)URBCOEF/mm−1DIRTMX/(kg·km−1)THALF/dTNCONC/(g·kg−1)TNO3CONC/(g·kg−1)TPCONC/(g·kg−1)URBCN2
    商业用地0.940.83260.138.191.6030.033.710.3098
    工业用地0.760.72150.1312.862.3541.463.800.5098
    高密住宅0.920.81340.1310.840.7581.549.170.6598
    中密住宅0.570.49300.1321.690.7521.401.790.2198
    交通道路0.900.90130.139.373.9038.804.480.3498
    公管用地0.440.35200.136.043.9017.801.720.1898
    下载: 导出CSV
  • [1] CHENG X, CHEN L D, SUN R H. Estimation of non-point source pollution loads of Beijing-Tianjin-Hebei region considering precipitation and topography[J]. Transactions of the Chinese Society of Agricultural Engineering, 2017, 124(9): 869-879.
    [2] 王军霞, 罗彬, 陈敏敏, 等. 城市面源污染特征及排放负荷研究: 以内江市为例[J]. 生态环境学报, 2014, 23(1): 151-156. doi: 10.3969/j.issn.1674-5906.2014.01.022
    [3] 杨龙, 孙长虹, 王永刚, 等. 城市面源污染负荷动态更新体系构建研究[J]. 环境保护科学, 2015, 41(2): 63-66. doi: 10.3969/j.issn.1004-6216.2015.02.013
    [4] RADCLIFFE D E, CABRERA M L, RADCLIFFE D E, et al. Modeling phosphorus in the environment[J]. Modeling Phosphorus in the Environment, 2007, 89(1): 278-283.
    [5] 李丹, 薛联青, 郝振纯. 基于SWAT模型的流域面源污染模拟影响分析[J]. 环境污染与防治, 2008, 30(3): 4-7. doi: 10.3969/j.issn.1001-3865.2008.03.003
    [6] 赵雪松. 基于改进的AnnAGNPS模型的区域农业面源污染模拟研究[J]. 水利技术监督, 2016, 24(4): 64-67. doi: 10.3969/j.issn.1008-1305.2016.04.024
    [7] 王昌根, 刘昌明, 黄友波. SWAT模型的原理、结构及应用研究[J]. 地理科学进展, 2003, 22(1): 79-86. doi: 10.3969/j.issn.1007-6301.2003.01.010
    [8] 温切尔, 邹兵. ArcSWAT 2009用户指南[M]. 郑州: 黄河水利出版社, 2012.
    [9] 阿诺德, 邹松兵. SWAT 2009输入输出文件[M]. 郑州: 黄河水利出版社, 2012.
    [10] BRIS F J, GARAUD S, APPERRY N, et al. A street deposit sampling method for metal and hydrocarbon contamination assessment[J]. Science of the Total Environment, 1999, 235(23): 211-220.
    [11] 常静, 刘敏, 侯立军, 等. 城市地表灰尘的概念、污染特征与环境效应[J]. 应用生态学报, 2007, 18(5): 1153-1158. doi: 10.3321/j.issn:1001-9332.2007.05.036
    [12] KIM J. Estimating pollutant mass accumulation on highways during dry periods[J]. Journal of Environmental Engineering, 2006, 27(3): 30-41.
    [13] 边博. 城市地表污染物累积模型研究[J]. 土木建筑与环境工程, 2010, 32(6): 137-141.
    [14] 施为光. 街道地表物的累积与污染特征: 以成都市为例[J]. 环境科学, 1991, 12(3): 18-23. doi: 10.3321/j.issn:0250-3301.1991.03.013
    [15] 芦昌兴, 王甲荣, 宫雪亮. 基于SWAT模型对洙赵新河流域径流的模拟研究[J]. 水资源与水工程学报, 2018, 29(6): 19-24.
    [16] 王立, 李海强, 马放. 基于SWAT模型的沙颍河上游非点源污染模拟研究[D]. 南京: 南京大学, 2015.
    [17] 白凤姣, 李天宏. 基于GIS和L-THIA模型的深圳市观澜河流域非点源污染负荷变化分析[J]. 环境科学, 2012, 33(8): 2667-2673.
  • 加载中
图( 9) 表( 3)
计量
  • 文章访问数:  6943
  • HTML全文浏览数:  6943
  • PDF下载数:  126
  • 施引文献:  0
出版历程
  • 收稿日期:  2019-11-20
  • 录用日期:  2020-03-01
  • 刊出日期:  2020-10-10
陈铁, 孙飞云, 杨淑芳, 陈立春, 熊向陨, 汪燕. 基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估[J]. 环境工程学报, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
引用本文: 陈铁, 孙飞云, 杨淑芳, 陈立春, 熊向陨, 汪燕. 基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估[J]. 环境工程学报, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
CHEN Tie, SUN Feiyun, YANG Shufang, CHEN Lichun, XIONG Xiangyun, WANG Yan. Load quantification and effect evaluation of urban non-point source pollution in the Guanlan river basin based on SWAT model[J]. Chinese Journal of Environmental Engineering, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108
Citation: CHEN Tie, SUN Feiyun, YANG Shufang, CHEN Lichun, XIONG Xiangyun, WANG Yan. Load quantification and effect evaluation of urban non-point source pollution in the Guanlan river basin based on SWAT model[J]. Chinese Journal of Environmental Engineering, 2020, 14(10): 2866-2875. doi: 10.12030/j.cjee.201911108

基于SWAT模型的观澜河流域城市面源污染负荷量化及影响效应评估

    通讯作者: 孙飞云(1982—),男,博士,副教授。研究方向:膜处理、海绵城市等。E-mail:sun_fy@hit.edu.cn
    作者简介: 陈铁(1994—),男,硕士研究生。研究方向:面源污染、海绵城市。E-mail:chentie_anywhere@qq.com
  • 1. 哈尔滨工业大学(深圳)土木与环境工程学院,深圳 518055
  • 2. 深圳市市政设计研究院有限公司,深圳 518029
  • 3. 深圳市环境监测中心站,深圳 518049
  • 4. 深圳市水务科技信息中心,深圳 518036
基金项目:
深圳市技术攻关项目(JSGG20170414101900541);深圳市基础研究项目(JCYJ20160406162038258)

摘要: 随着我国城市区域污水收集、截污系统的完善与水质净化厂出水标准的提高,点源污染逐步得到控制,城市面源污染对河流水质的影响越来越凸显。针对当前城市内河流集水区域城市面源污染负荷难以量化、对水体水质影响效应难以解析等问题,以深圳市观澜河流域为研究对象,通过对流域的现场勘察调研与地表累积物采样研究,来修正流域土地利用类型数据与SWAT模型的城镇数据库,构建流域城市面源污染评价模型。结果表明:SWAT模型城镇数据库中地表沉积物最大累积量(DIRTMX)、地表沉积物中总氮含量(TNCONC)、地表灰尘累积半饱和时长(TNALF)与地表灰尘总磷含量(TPCONC)对TN与TP负荷的模拟最为敏感;建立的SWAT模型对观澜河流域径流量、TP与TN模拟验证期的纳什效率系数(ENS)分别为0.79、0.7、0.67,决定系数(R2)分别为0.81、0.77、0.81,模型拟合结果较好。应用SWAT模型分析了2018年观澜河流域TN和TP的城市面源污染时空分布特征:TN和TP输出最高值为13.31~14.91 t·km−2和1.69~1.86 t·km−2;8月份观澜河流域降雨径流污染最为严重,TN和TP负荷分别为2.15 t·km−2与0.24 t·km−2。上述评估结果可为区域城市面源污染的负荷量化与影响效应评估提供参考。

English Abstract

  • 在我国城市区域,由于不透水区域占比较大、生产活动复杂、污染来源多样,导致城市内河流污染较为严重。城市面源污染是仅次于农业面源污染的第二大面源污染源[1]。近年来,随着我国城市区域污水收集、截污系统的完善与水质净化厂出水标准的提高,点源污染逐步得到控制,城市面源污染对河流水质的影响越来越凸显,急需对城市内河流面源污染进行负荷量化与影响效应研究,为城市内河流水质进一步改善提供数据支持。

    目前,国内对于城市面源污染的负荷量化多利用经验公式进行估算,缺乏较为精确的负荷量化方法。王军霞等[2]通过对内江市不同城市下垫面场次降雨事件平均浓度的研究,估算了内江市全年降雨径流污染中氨氮、COD、TN与TP负荷;杨龙等[3]基于事件平均浓度统计法,估算了2012年北京市城市面源污染物SS、COD等污染物负荷。随着科技水平的提高,西方发达国家开发了大量的分布式水文模型(如SWAT、HSPF、AnnAGNPS模型等[4]),能实现对大尺度流域农业面源污染负荷较高精度的模拟,但对于城市内河流的小尺度流域的城市面源污染的负荷量化与影响效应分析的模型应用研究较为缺乏。李丹等[5]利用改进的SWAT模型,模拟了对太湖流域浙西区的西苕溪流域面源污染TN与TP负荷;赵雪松[6]利用改进的AnnAGNPS模型,实现了对汤河西支流域农业面源污染TN与TP负荷较高精度的模拟。

    深圳市观澜河流域为典型的城市内河流集水区域。目前观澜河流域内各水质净化厂出水已达到地表准Ⅳ类,对于区域的截污系统日臻完善,城市面源污染成为影响观澜河水质的主要污染类型。因此,选择深圳市观澜河流域为研究对象,模拟分析城市内河流面源污染的潜在模型——SWAT模型,通过现场勘察调研与地表累积物采样研究,来修正所获取的土地利用数据与模型城镇数据库,从而实现对于观澜河流域的城市面源污染负荷量化与影响效应解析,为我国类似城市内河流的城市面源污染分析提供参考。

  • 观澜河流域位于我国南方深圳市中北部,北与东莞市交界,流域总集水面积为189.66 km2。观澜河流域地处北回归线以南,属南亚热带海洋性季风气候,夏季盛行东南风和西南风。观澜河流域多年平均气温为22 ℃,多年平均降雨量为1 825 mm,且降雨量在全年分布不均,4—9月为雨季,降雨量约占全年降雨量的84%。观澜河流域集水区域内包含一条干流及14条一级支流,其中干流观澜河沿河建有的水质处理设施包括龙华水质净化厂一期、二期,观澜水质净化厂一期、二期,坂雪岗水质净化厂、清湖人工湿地与观澜河口调蓄池,是观澜河主要的点源输入与补水水源。观澜河流域地理位置与流域水系分布如图1所示。

  • SWAT模型是常见的面源污染分析模型,其组成包括降雨模拟、产汇流、河流水质扩散等模块[7]。SWAT模型因具有农药/杀虫剂组件与农业管理组件,因此,常被运用于模拟流域农业面源污染,而很少用于城市面源污染的研究。通过《ArcSWAT 2009用户指南》[8]以及《SWAT 2009输入输出文件手册》[9],发现2009以上的版本的SWAT模型具有城镇数据库,已完善了流域土地利用数据与模型城镇数据库,可以用SWAT模型模拟流域城市面源污染。SWAT模型城镇数据库的关键参数[9]表1所示。

    本研究通过对研究区域地表累积物的监测分析确定DIRTMX、TNCONC、TPCONC与TNO3CONC的取值。目前,通常的地表累积物采样方法有2大类:干式采样法和湿式采样法[10]。干式采样法根据使用工具可以细分为用毛刷或者扫帚清扫法与用吸尘器真空采样法。湿式采样法是先利用去离子水清洗地面,在通过真空吸尘机吸取泥水混合样[11]。本研究采用羊毛刷与800 W德国卡赫真空吸尘器对研究区域进行干式采样,其采样过程如下。

    1) 在选定的采样区域沿街道边石布点采样,根据采样区域面积确定采样点数,每个区域布点不少于5个,在采样处放置自制的1.0 m×1.0 m的采样框,在框内采集。

    2) 采样时,先用吸尘器横竖交叉吸取框内灰尘,然后再用毛刷往复清扫框内地表,以使紧密附着在地表的颗粒物脱离,再使用真空吸尘器吸取框内灰尘,以此重复3~5次。

    3) 将真空吸尘器集尘袋内收集的地表灰尘移入无菌采样袋内并贴好标签。

    已有研究表明,地表污染物随着雨前干旱时长最终会趋于饱和。KIM[12]通过研究美国南加州高速公路的地表累积物中TSS、COD等污染物随雨前干旱时长的累积速率,发现时长为10~70 d内的TSS与COD的累积速率相比1~10 d分别下降了79%与78%。边博[13]通过对城市地表污染物累积过程的研究发现雨期干旱时长在7 d以上,地表污染物含量达到饱和。因此,本研究选择在雨前晴时长为7 d以上的无风条件下进行采样,远离清扫时间,收集一个区域内的混合样品。本研究所布设观澜河流域地表污染物累积监测点位主要集中在2个片区,采样覆盖区域面积可达22 km2,布设的采样片区内覆盖了观澜河流域主要的6类城市用地类型(图2):工业用地、高密度住宅用地(简称高密住宅)、中密度住宅用地(简称中密住宅)、商业用地、交通用地与公共管理服务用地(简称公管用地),每个片区内所布设的6类城市用地类型地表沉积物采样取样均为5个,故总的2个片区内6类城市用地类型采样区域总数为60个。为确定观澜河6类城市用地类型的DIRTMX、TNCONC、TPCONC与TNO3CONC的取值,在2018年10月—2019年10月,进行了5次地表污染物累积采样监测,采样包括降雨次数较多的雨季与降雨次数较少的旱季时期,共获得样品数300个。

  • 根据施为光[14]的研究,城市降雨径流污染主要是由粒径为50~1 000 μm的细尘引起的。因此,本研究对收集到的地表累积物使用金属筛进行筛分,对于小于1 mm的颗粒物样品进行称量并记录,再反复颠簸以使不同粒径的颗粒能均匀分布,每个样品取5 g溶于1 L的去离子水中,测混合后水样的TN、硝态氮以及TP,每组样品设置3组平行样品。

    本研究通过基础数据收集、现场监测分析相结合的手段来获取SWAT构建所需要的相关数据,数据类型可分为空间数据和地表观测数据2个部分,与以往研究不同的是,观澜河流域农业用地较少,城镇用地占比较大,因此,在进行数据收集时,不收集农业管理数据。SWAT模型构建所需数据及基本信息如表2所示。

    为了便于模型的构建,须对空间数据进行预处理,图3是本研究所收集到的原始空间数据以及处理后的数据。

    本研究选择时空不确定性适应算法SUFI-2进行模型的校准与参数率定。该方法是一种全局敏感性分析法,取决于目标函数值与拉丁超立方生成的参数之间的多元回归系统,其表达式[15]见式(1)。

    每个参数bi相对显著性用t检验来确定,各参数的敏感度用算法输出参数tstat来衡量,绝对值越大,则敏感度越高。

    对于SWAT模型的模拟结果验证,本研究使用决定系数R2与纳什效率系数ENS进行综合评价,其计算方法见式(2)和式(3)。当ENS≥0.5且R2≥0.6时,模型拟合结果较好[16]

    式中:Qt0t时刻的观测值;Qtmt时刻的模拟值;¯Q0为观测值的平均值;ENS取值为负无穷至1,ENS接近1,表示拟合程度好,模型可信度高。

    式中:¯Qm为模拟值的平均值;R2的取值范围为0~1,R2值越接近于1,则模型拟合程度越高。

  • 通过对观澜河流域城镇用地类型的地表累积物的采样研究,参考《SWAT 2009输入输出手册》[9]提供的相关参数范围和观澜河流域已有的研究成果,构建了观澜河流域SWAT模型城镇数据库。其中FIMP、FCIMP、CURBDEN根据现场研究确定,DIRTMX、TNCONC、TPCONC与TNO3CONC根据地表沉积物研究确定,URBCOEF、THALF、URBCN2参考《SWAT 2009输入输出手册》[9]与白凤姣等[17]关于深圳市观澜河流域CN值的校正研究确定。

    图4所示,观澜河流域6类城市用地类型地表沉积物的DIRTMX的均值中最大值为中密度居住区21.69 kg·km−1,最小值为公管用地6.04 kg·km−1;TNCONC的均值最大值为高密度居住区81.54 g·kg−1,最小值为公管用地17.80 g·kg−1;TNO3CONC的均值最大值为高密度居住区9.17 g·kg−1,最小值为公管用地1.72 g·kg−1;TPCONC的均值最大值为高密度居住区0.65 g·kg−1,最小值为公管用地0.18 g·kg−1。建立的SWAT模型城镇数据库关键参数初始数值如表3所示,SWAT模型的城镇数据库的DIRTMX、TNCONC、TNO3CONC与TPCONC在观澜河流域的实测值与SWAT模型提供的参考值差别较大,这是由于SWAT模型城镇数据库默认的参数值是基于美国城市建设区域的相关研究,与我国城市面源污染现状差别较大。因此,在构建SWAT模型研究流域城市面源污染时,须根据当地特征修正模型SWAT模型城镇数据库参数值。

  • 设置不同的子流域集水面积能影响SWAT模型基于观澜河流域DEM数据生成河流情况与子流域生成个数。本研究通过多次设置子流域的集水面积,发现子流域的集水面积≥300 hm2时,SWAT模型生成的观澜河流域河流情况与实际较为一致,其划分的子流域为34个。根据观澜河流域特征本研究设定的土壤类型面积阈值为15%,用地类型面积阈值为0,坡度分为3级:<2%,2%~5%与>5%,共划分为326个HRUs。通过SUIF-2对参数进行敏感性分析,确定了流域中对径流最为敏感的10个参数,以及对氮磷负荷最为敏感的10个参数,其中径流曲线数、土壤饱和导水率、土壤有效含水量与地下水滞后系数对径流量的模拟最为敏感;有效磷沉降速率、地表灰尘TP含量、地表灰尘TN含量与地表灰尘最大累积量对TN与TP的模拟最为敏感(图5)。本研究收集到观澜河流域控制断面——企坪断面2014—2018年的水量与水质数据,以此对企坪断面进行了径流量与水质的校准和验证,模拟步长设置为月,以ENS≥0.5、R2≥0.6为判断运行结束的标准。

    月径流量、TP与TN负荷的模拟值与实测值分析对比结果见图6。月径流量校准期的ENS为0.83,R2为0.93;验证期的ENS为0.79,R2为0.81。月TN与TP负荷的校准期的ENS分别为0.70、0.68,R2分别为0.86、0.87;月TN与TP负荷验证期的ENS分别为0.7、0.67,R2分别为0.77、0.81。由此可见,模型模拟结果可信度较高,与实际值的拟合度较好,这与城镇数据库参数修正的结论一致:DIRTMX、TNCONC、TPCONC与THALF是模型建立的关键参数。

  • 通过SWAT模型分析了2018年观澜河流域TN与TP单位面积的面源污染输出负荷的空间分布特征与各类型功能区输出的面源污染负荷对总负荷的贡献率(图7图8)。2018年,观澜河流域TN与TP单位面积的面源污染输出负荷的空间分布特征表现一致,均在子流域为10、15、26、31号子流域内最高,分别为TN 13.31~14.91 t·km−2和TP 1.69~1.86 t·km−2。在观澜河流域6类功能区中,高密度居住区输出的TN与TP负荷贡献最高,分别为52%和49%,其次是工业用地,分别为27%和32%,公管用地最低,分别为1.5%和2.3%。

  • 观澜河流域主要的输入点源为干流沿岸建设的水质净化厂尾水,通过利用收集到的2018年观澜河流域各水质净化厂尾水水量与水质日变化数据,建立SWAT模型的点源输入数据库,并基于模型分析了2018年观澜河流域城市面源污染对控制断面——企坪断面处水体TN与TP负荷的贡献情况(图9)。2018年观澜河流域4—9月的降雨径流污染产生的TN与TP负荷均高于1—3月份、10—12月,8月观澜河流域降雨径流污染最为严重,TN与TP负荷分别为2.15 t·km−2与0.24 t·km−2

  • 1) 通过对观澜河流域6类城市用地类型的地表沉积物采样监测研究与区域的现场调研,构建了SWAT模型城镇数据库并对数据库参数进行了本地化校正,发现:SWAT模型的城镇数据库的DIRTMX、TNCONC、TNO3CONC与TPCONC这4类参数在观澜河流域的实测值与SWAT模型提供的参考值差别较大,后续的相关研究应重点关注这几类城镇数据库参数的本地化校正。

    2) SWAT模型参数敏感性分析表明:参数DIRTMX、TNCONC、TNALF与TPCONC对月TN与TP负荷的模拟最为敏感;构建的SWAT模型对控制断面径流量、TP与TN负荷模拟验证期的ENS分别为0.79、0.68和0.67,R2分别为0.81、0.87和0.81,模型模拟结果可信度较高,与实际值的拟合度较好。同时表明,通过对流域地表累积物的采样研究,建立并校正SWAT模型城镇数据库的方式来构建流域城市面源污染分析的SWAT模型的方法可行。

    3) 利用SWAT模型分析2018年观澜河流域TN与TP的时空分布特征发现:观澜河流域TN与TP单位面积年输出负荷空间分布最高值为TN 13.31~14.91 t·km−2和TP 1.69~1.86 t·km−2;在流域6类城市用地类型中,高密度住宅区输出的TN与TP负荷贡献最高,分别为52%与49%,公共管理服务用地最低,分别为1.5%与2.3%;2018年观澜河流域4—9月的降雨径流污染产生的TN与TP负荷均高于1—3月、10—12月,8月观澜河流域降雨径流污染最为严重,TN与TP负荷分别为:2.15 t·km−2和0.24 t·km−2

参考文献 (17)

返回顶部

目录

/

返回文章
返回