Xue Yong. Research and development on the technology and device for purification of flue gas from coal furnace kiln[J]. Chinese Journal of Environmental Engineering, 2007, 1(10): 74-78.
Citation: Xue Yong. Research and development on the technology and device for purification of flue gas from coal furnace kiln[J]. Chinese Journal of Environmental Engineering, 2007, 1(10): 74-78.

Research and development on the technology and device for purification of flue gas from coal furnace kiln

  • Received Date: 15/06/2007
    Accepted Date: 09/12/2006
    Fund Project:
  • Research on the integrated desulphurization technology of blowout calcium and water bath and its device for purifying smoke gas from coal-burning was performed. The experiments indicated that the integrated desulphurization technology of calcium spurt and water bath has a higher desulphurization effect than that of single spurt calcium process or the water bath possess, and calcium carbonate spurted can get fully utilization. In addition, factors influencing desulphurization efficiency,such as the ratio between calcium and sulphur,the direction of calcium spurted and the depth of nozzle into water were tested.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1741) PDF downloads(945) Cited by(0)

Access History

Research and development on the technology and device for purification of flue gas from coal furnace kiln

Fund Project:

Abstract: Research on the integrated desulphurization technology of blowout calcium and water bath and its device for purifying smoke gas from coal-burning was performed. The experiments indicated that the integrated desulphurization technology of calcium spurt and water bath has a higher desulphurization effect than that of single spurt calcium process or the water bath possess, and calcium carbonate spurted can get fully utilization. In addition, factors influencing desulphurization efficiency,such as the ratio between calcium and sulphur,the direction of calcium spurted and the depth of nozzle into water were tested.

Reference (0)

Catalog

/

DownLoad:  Full-Size Img  PowerPoint