[1] |
LIU Z Y. Urban sewage treatment odor gas release characteristics and regional differences [J]. Environmental Technology & Innovation, 2021, 21: 101190.
|
[2] |
王鑫, 池皓, 张鑫倩, 等. 炼化企业污水处理厂恶臭治理设施排放特征及污染控制策略 [J]. 环境工程学报, 2021, 15(7): 2333-2343. doi: 10.12030/j.cjee.202102027
WANG X, CHI H, ZHANG X Q, et al. Emission characteristics and control strategy of odor treatment processes in refinery wastewater treatment plants [J]. Chinese Journal of Environmental Engineering, 2021, 15(7): 2333-2343(in Chinese). doi: 10.12030/j.cjee.202102027
|
[3] |
KECK M, MAGER K, WEBER K, et al. Odour impact from farms with animal husbandry and biogas facilities [J]. Science of the Total Environment, 2018, 645: 1432-1443. doi: 10.1016/j.scitotenv.2018.07.182
|
[4] |
ZILIO M, ORZI V, CHIODINI M, et al. Evaluation of ammonia and odour emissions from animal slurry and digestate storage in the Po Valley (Italy) [J]. Waste Management, 2020, 103: 296-304. doi: 10.1016/j.wasman.2019.12.038
|
[5] |
李永双, 孙波, 陈菊红, 等. 纳米膜覆盖对畜禽粪便好氧堆肥进程及恶臭气体排放的影响 [J]. 环境科学, 2021, 42(11): 5554-5562. doi: 10.13227/j.hjkx.202103109
LI Y S, SUN B, CHEN J H, et al. Effects of nano-membrane on aerobic composting process and odor emission of livestock manure [J]. Environmental Science, 2021, 42(11): 5554-5562(in Chinese). doi: 10.13227/j.hjkx.202103109
|
[6] |
CAPELLI L, SIRONI S, del ROSSO R, et al. A comparative and critical evaluation of odour assessment methods on a landfill site [J]. Atmospheric Environment, 2008, 42(30): 7050-7058. doi: 10.1016/j.atmosenv.2008.06.009
|
[7] |
周巧丽, 宋玉梅, 周漪波, 等. 广州市某生活垃圾填埋场空气及地下水污染状况分析 [J]. 环境化学, 2019, 38(4): 760-769. doi: 10.7524/j.issn.0254-6108.2018061302
ZHOU Q L, SONG Y M, ZHOU Y B, et al. Analysis of air and groundwater pollution in a municipal solid waste landfill site in Guangzhou [J]. Environmental Chemistry, 2019, 38(4): 760-769(in Chinese). doi: 10.7524/j.issn.0254-6108.2018061302
|
[8] |
JIA H H, GAO S, DUAN Y S, et al. Investigation of health risk assessment and odor pollution of volatile organic compounds from industrial activities in the Yangtze River Delta region, China [J]. Ecotoxicology and Environmental Safety, 2021, 208: 111474. doi: 10.1016/j.ecoenv.2020.111474
|
[9] |
陈凌霄, 修光利, 黄银芝. 聚氨酯和聚碳酸酯制造过程的恶臭排放特征和指纹谱 [J]. 环境工程学报, 2021, 15(2): 755-764. doi: 10.12030/j.cjee.202005008
CHEN L X, XIU G L, HUANG Y Z. Characteristics and fingerprint spectra of odor pollutants emitted from typical production process of polyurethane and polycarbonate [J]. Chinese Journal of Environmental Engineering, 2021, 15(2): 755-764(in Chinese). doi: 10.12030/j.cjee.202005008
|
[10] |
BRANCHER M, GRIFFITHS K D, FRANCO D, et al. A review of odour impact criteria in selected countries around the world [J]. Chemosphere, 2017, 168: 1531-1570. doi: 10.1016/j.chemosphere.2016.11.160
|
[11] |
SUCKER K, BOTH R, WINNEKE G. Review of adverse health effects of odours in field studies [J]. Water Science and Technology, 2009, 59(7): 1281-1289. doi: 10.2166/wst.2009.113
|
[12] |
WU C D, LIU J M, LIU S H, et al. Assessment of the health risks and odor concentration of volatile compounds from a municipal solid waste landfill in China [J]. Chemosphere, 2018, 202: 1-8. doi: 10.1016/j.chemosphere.2018.03.068
|
[13] |
LIU Y J, LIU Y T, LI H, et al. Health risk impacts analysis of fugitive aromatic compounds emissions from the working face of a municipal solid waste landfill in China [J]. Environment International, 2016, 97: 15-27. doi: 10.1016/j.envint.2016.10.010
|
[14] |
国家环境保护局, 国家技术监督局. 恶臭污染物排放标准: GB14554—1993[S]. 北京: 中国标准出版社, 1994.
State Bureau of Environmental Protection of the People's Republic of China, State Bureau of Quality and Technical Supervision of the People's Republic of China. Emission STANDARDs for odor pollutants: GB14554—1993[S]. Beijing: Standards Press of China, 1994(in Chinese).
|
[15] |
章轲. 恶臭居环保举报榜首, 治理市场混乱、技术低效是主要症结 [N]. 第一财经, 2020-11-11.
ZHANG K. Odor ranks first in environmental protection reports, the main crux of the problem is the management of market chaos and technical inefficiency[N]. YICAI, 2020-11-11.
|
[16] |
WANG Y C, HAN M F, JIA T P, et al. Emissions, measurement, and control of odor in livestock farms: A review [J]. Science of the Total Environment, 2021, 776: 145735. doi: 10.1016/j.scitotenv.2021.145735
|
[17] |
MELSE R W, HOL J M G. Biofiltration of exhaust air from animal houses: Evaluation of removal efficiencies and practical experiences with biobeds at three field sites [J]. Biosystems Engineering, 2017, 159: 59-69. doi: 10.1016/j.biosystemseng.2017.04.007
|
[18] |
国家技术监督局. 空气质量 恶臭的测定 三点比较式臭袋法: GB/T14675—1993[S]. 北京: 中国标准出版社, 1993.
State Bureau of Quality and Technical Supervision of the People's Republic of China. Air quality-Determination of odor-Triangle odor bag method: GB/T14675—1993[S]. Beijing: Standards Press of China, 1993(in Chinese).
|
[19] |
EN 13725∶2003, Air quality—Determination of odour concentration by dynamic olfactometry[S].
|
[20] |
ASTM E679‐04 , Standard Practice for Determination of Odor and Taste Thresholds By a Forced‐Choice Ascending Concentration Series Method of Limits[S].
|
[21] |
VDI 3881/Part 2, Olfactometry—odour threshold determination—sampling[S].
|
[22] |
HANSEN M, JONASSEN K E N, FEILBERG A. Evaluation of abatement technologies for pig houses by dynamic olfactometry and on-site mass spectrometry [J]. Chemical Engineering Transactions, 2014, 40: 253-258.
|
[23] |
CAPELLI L, SIRONI S, DEL ROSSO R, et al. Olfactory and toxic impact of industrial odour emissions [J]. Water Science and Technology, 2012, 66(7): 1399-1406. doi: 10.2166/wst.2012.352
|
[24] |
CAPELLI L, SIRONI S, del ROSSO R, et al. Olfactometric approach for the evaluation of citizens' exposure to industrial emissions in the city of Terni, Italy [J]. The Science of the Total Environment, 2011, 409(3): 595-603. doi: 10.1016/j.scitotenv.2010.10.054
|
[25] |
ROMAIN A C, NICOLAS J, COBUT P, et al. Continuous odour measurement from fattening pig units [J]. Atmospheric Environment, 2013, 77: 935-942. doi: 10.1016/j.atmosenv.2013.06.030
|
[26] |
NEWBY B D, MCGINLEY M A. Ambient odour testing of concentrated animal feeding operations using field and laboratory olfactometers [J]. Water Science and Technology, 2004, 50(4): 109-114. doi: 10.2166/wst.2004.0235
|
[27] |
BLAZY V, de GUARDIA A, BENOIST J C, et al. Correlation of chemical composition and odor concentration for emissions from pig slaughterhouse sludge composting and storage [J]. Chemical Engineering Journal, 2015, 276: 398-409. doi: 10.1016/j.cej.2015.04.031
|
[28] |
FRIEDRICH M, KOSMIDER J. Precision of odour abatement efficiency determination in changing conditions [J]. Chemical Engineering Transactions , 2012, 30: 265-270.
|
[29] |
GUTIÉRREZ M C, MARTÍN M A, PAGANS E, et al. Dynamic olfactometry and GC-TOFMS to monitor the efficiency of an industrial biofilter [J]. Science of the Total Environment, 2015, 512/513: 572-581. doi: 10.1016/j.scitotenv.2015.01.074
|
[30] |
PARKER D B, RHOADES M B, SCHUSTER G L, et al. Odor characterization at open-lot beef cattle feedyards using triangular forced-choice olfactometry [J]. Transactions of the ASAE, 2005, 48(4): 1527-1535. doi: 10.13031/2013.19184
|
[31] |
CAPELLI L, SIRONI S, del ROSSO R. Odor sampling: Techniques and strategies for the estimation of odor emission rates from different source types [J]. Sensors (Basel, Switzerland), 2013, 13(1): 938-955. doi: 10.3390/s130100938
|
[32] |
JONASSEN K, PEDERSEN P, RIIS A, et al. Does the choice of olfactometric laboratory affect the efficiency of odour abatement technologies? [J]. Chemical Engineering Transactions , 2012, 30: 43-270.
|
[33] |
恶臭防治法[S].
Offensive Odor Control Law[S] (in Chinese).
|
[34] |
NAGATA Y, TAKEUCHI N. Measurement of odor threshold by triangle odor bag method [J]. Odor measurement review, 2003, 118: 118-127.
|
[35] |
HANAJIMA D, KURODA K, MORISHITA K, et al. Key odor components responsible for the impact on olfactory sense during swine feces composting [J]. Bioresource Technology, 2010, 101(7): 2306-2310. doi: 10.1016/j.biortech.2009.11.026
|
[36] |
LU W J, DUAN Z H, LI D, et al. Characterization of odor emission on the working face of landfill and establishing of odorous compounds index [J]. Waste Management, 2015, 42: 74-81. doi: 10.1016/j.wasman.2015.04.030
|
[37] |
肖洋, 王新娟, 韩伟. 工业城市有机化工异味应急监测快速溯源 [J]. 中国环境监测, 2015, 31(2): 126-129. doi: 10.3969/j.issn.1002-6002.2015.02.025
XIAO Y, WANG X J, HAN W. Study of rapid tracing of organic chemical odor emergency monitoring for industrial city [J]. Environmental Monitoring in China, 2015, 31(2): 126-129(in Chinese). doi: 10.3969/j.issn.1002-6002.2015.02.025
|
[38] |
CUI Y Y, ZHAI X M, WANG B C, et al. Characteristics and control measures of odor emissions from crematoriums in Beijing, China [J]. SN Applied Sciences, 2021, 3(8): 1-9.
|
[39] |
张旭东. 恶臭动态稀释法在三点比较式臭袋法中的应用探讨 [J]. 环境与可持续发展, 2016, 41(4): 80-82. doi: 10.3969/j.issn.1673-288X.2016.04.024
ZHANG X D. Discussion on the application of odor dynamic dilution method in the three point comparison method [J]. Environment and Sustainable Development, 2016, 41(4): 80-82(in Chinese). doi: 10.3969/j.issn.1673-288X.2016.04.024
|
[40] |
安慧, 赵东风, 张庆冬, 等. 恶臭嗅觉测定研究性实验教学设计 [J]. 实验室研究与探索, 2019, 38(7): 196-199. doi: 10.3969/j.issn.1006-7167.2019.07.047
AN H, ZHAO D F, ZHANG Q D, et al. Experimental teaching design for odor olfactory detection [J]. Research and Exploration in Laboratory, 2019, 38(7): 196-199(in Chinese). doi: 10.3969/j.issn.1006-7167.2019.07.047
|
[41] |
戎梅. 浅谈三点比较式臭袋法在恶臭监测中的应用// 国家环境保护恶臭污染控制重点实验室. 恶臭污染防治研究进展——第四届全国恶臭污染测试与控制技术研讨会论文集[C]; 2012: 3.
Rong M. Discussion on the application of triangle odor bag method in malodor monitoring//National Key Laboratory of Odor Pollution Control for Environmental Protection. Progress in Research on Odor Pollution Prevention-Proceedings of the Fourth National Symposium on Odor Pollution Testing and Control Technology[C]; 2012: 3(in Chinese).
|
[42] |
HANSEN M J, JONASSEN K E N, LØKKE M M, et al. Multivariate prediction of odor from pig production based on in situ measurement of odorants [J]. Atmospheric Environment, 2016, 135: 50-58. doi: 10.1016/j.atmosenv.2016.03.060
|
[43] |
王媛媛, 王琪, 李贝, 等. 恶臭国标测定方法和便携式恶臭测定仪测定结果的比对分析 [J]. 环境监控与预警, 2017, 9(5): 20-23. doi: 10.3969/j.issn.1674-6732.2017.05.006
WANG Y Y, WANG Q, LI B, et al. Comparative analysis of odor determination by national standard method and portable odor tester [J]. Environmental Monitoring and Forewarning, 2017, 9(5): 20-23(in Chinese). doi: 10.3969/j.issn.1674-6732.2017.05.006
|
[44] |
IDES Canada Inc. SM100 portable olfactometer[EB/OL].
|
[45] |
WIŚNIEWSKA M. Methods of assessing odour emissions from biogas plants processing municipal waste [J]. Journal of Ecological Engineering, 2020, 21(1): 140-147. doi: 10.12911/22998993/113039
|
[46] |
HAWKO C, VERRIELE M, HUCHER N, et al. A review of environmental odor quantification and qualification methods: The question of objectivity in sensory analysis [J]. Science of the Total Environment, 2021, 795: 148862. doi: 10.1016/j.scitotenv.2021.148862
|
[47] |
BYLIŃSKI H, LEWKOWSKA P, GĘBICKI J, et al. Identification of aromatic compounds in odours mixture by gas chromatography and field olfactometry techniques [J]. Proceedings of the 12th Modern Analytical Chemistry, 2016: 108-112.
|
[48] |
BARCZAK R, KULIG A. Odour monitoring of a municipal wastewater treatment plant in Poland by field olfactometry [J]. Chemical Engineering Transactions, 2016, 54: 331-336.
|
[49] |
DALTON P, CARAWAY E A, GIBB H, et al. A multi-year field olfactometry study near a concentrated animal feeding operation [J]. Journal of the Air & Waste Management Association, 2011, 61(12): 1398-1408.
|
[50] |
BAKHTARI A, MEDINA S. Enhancing VDI3940 grid method via in-field olfactometry to obtain complete odour impact assessment [J]. Chemical Engineering Transactions, 2016, 54: 283-288.
|
[51] |
BADACH J, KOLASIŃSKA P, PACIOREK M, et al. A case study of odour nuisance evaluation in the context of integrated urban planning [J]. Journal of Environmental Management, 2018, 213: 417-424.
|
[52] |
HOVE N C Y, DEMEYER P, van der HEYDEN C, et al. Improving the repeatability of dynamic olfactometry according to EN 13725: A case study for pig odour [J]. Biosystems Engineering, 2017, 161: 70-79. doi: 10.1016/j.biosystemseng.2017.06.004
|
[53] |
KULIG A, SZYŁAK-SZYDŁOWSKI M. Assessment of the effects of wastewater treatment plant modernization by means of the field olfactometry method [J]. Water, 2019, 11(11): 2367. doi: 10.3390/w11112367
|
[54] |
MILLER R M, MCGINLEY M A. Evaluation of background odour in tedlar and nalophan sample bags [J]. Proceedings of the Water Environment Federation, 2008, 2008(4): 590-604. doi: 10.2175/193864708788808032
|
[55] |
PARKER D B, RHOADES M B, KOZIEL J, et al. Background odors in tedlar® bags used for CAFO odor sampling[C]//2003, Las Vegas, NV July 27-30, 2003. St. Joseph, MI: American Society of Agricultural and Biological Engineers, 2003.
|
[56] |
LAOR Y, RAVID U, HANAN A, et al. Uncertainty of olfactometry measurements caused by sampling issues [J]. Proceedings of the Water Environment Federation, 2012, 2012(3): 1-12. doi: 10.2175/193864712811700444
|
[57] |
PAPURELLO D. Direct injection mass spectrometry technique for the odorant losses at ppb(v) level from nalophan™ sampling bags [J]. International Journal of Mass Spectrometry, 2019, 436: 137-146. doi: 10.1016/j.ijms.2018.12.008
|
[58] |
MCGARVEY L J, SHORTEN C V. The effects of adsorption on the reusability of tedlar® air sampling bags [J]. AIHAJ - American Industrial Hygiene Association, 2000, 61(3): 375-380. doi: 10.1080/15298660008984546
|
[59] |
VAN HARREVELD A. Update on the revised EN 13725: 2021 [J]. Chemical Engineering Transactions, 2021, 85: 115.
|
[60] |
TOLEDO M, GUILLOT J M, SILES J A, et al. Permeability and adsorption effects for volatile sulphur compounds in Nalophan sampling bags: Stability influenced by storage time [J]. Biosystems Engineering, 2019, 188: 217-228. doi: 10.1016/j.biosystemseng.2019.10.023
|
[61] |
LI Q, FU X A, XU K Y, et al. A stability study of carbonyl compounds in Tedlar bags by a fabricated MEMS microreactor approach [J]. Microchemical Journal, 2021, 160: 105611. doi: 10.1016/j.microc.2020.105611
|
[62] |
HANSEN M J, ADAMSEN A P S, FEILBERG A, et al. Stability of odorants from pig production in sampling bags for olfactometry [J]. Journal of Environmental Quality, 2011, 40(4): 1096-1102. doi: 10.2134/jeq2010.0497
|
[63] |
MAN Z, DAI X R, RONG L, et al. Evaluation of storage bags for odour sampling from intensive pig production measured by proton-transfer-reaction mass-spectrometry [J]. Biosystems Engineering, 2020, 189: 48-59. doi: 10.1016/j.biosystemseng.2019.11.007
|
[64] |
KASPER P L, OXBØL A, HANSEN M J, et al. Mechanisms of loss of agricultural odorous compounds in sample bags of nalophan, tedlar, and PTFE [J]. Journal of Environmental Quality, 2018, 47(2): 246-253. doi: 10.2134/jeq2017.07.0289
|
[65] |
KONG X K, WANG L P, XIN Y C, et al. Evaluation of pre-Flushing for the recovery of odorants from intensive pig production in sampling bags measured by PTR-MS[C]//2018 Detroit, American Society of Agricultural and Biological Engineers, 2018: 1.
|
[66] |
MAURER D L, BRAGDON A M, SHORT B C, et al. Improving environmental odor measurements: Comparison of lab-based standard method and portable odor measurement technology [J]. Archives of Environmental Protection, 2018, 44(2): 100-107.
|
[67] |
HANSEN M J, ADAMSEN A P S, FEILBERG A. Recovery of odorants from an olfactometer measured by proton-transfer-reaction mass spectrometry [J]. Sensors , 2013, 13(6): 7860-7871. doi: 10.3390/s130607860
|
[68] |
NADDEO V, ZARRA T, OLIVA G, et al. Odour measurement in wastewater treatment plant by a new prototype of e. Nose: Correlation and comparison study with reference to both European and Japanese approaches [J]. Chemical Engineering Transactions, 2016, 54: 85-90.
|
[69] |
WALGRAEVE C, van HUFFEL K, BRUNEEL J, et al. Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry [J]. Biosystems Engineering, 2015, 137: 84-94. doi: 10.1016/j.biosystemseng.2015.07.007
|
[70] |
HOVE N C Y, van LANGENHOVE H, van WEYENBERG S, et al. Comparative odour measurements according to EN 13725 using pig house odour and n-butanol reference gas [J]. Biosystems Engineering, 2016, 143: 119-127. doi: 10.1016/j.biosystemseng.2016.01.002
|