融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例

郑才林, 江慧, 陈浩, 郑文雅, 周龙飞, 张旭, 彭文涛, 王业飞. 融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例[J]. 环境工程学报, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
引用本文: 郑才林, 江慧, 陈浩, 郑文雅, 周龙飞, 张旭, 彭文涛, 王业飞. 融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例[J]. 环境工程学报, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
ZHENG Cailin, JIANG Hui, CHEN Hao, ZHENG Wenya, ZHOU Longfei, ZHANG Xu, PENG Wentao, WANG Yefei. Design and operation of und erground reclaimed water plant merging into urban eco-landscape:A case study of Ankang Jiangnan reclaimed water plant[J]. Chinese Journal of Environmental Engineering, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
Citation: ZHENG Cailin, JIANG Hui, CHEN Hao, ZHENG Wenya, ZHOU Longfei, ZHANG Xu, PENG Wentao, WANG Yefei. Design and operation of und erground reclaimed water plant merging into urban eco-landscape:A case study of Ankang Jiangnan reclaimed water plant[J]. Chinese Journal of Environmental Engineering, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031

融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例

    作者简介: 郑才林(1981—),男,大学本科,高级工程师。研究方向:市政技术与管理。E-mail:516046316@qq.com
    通讯作者: 郑才林, E-mail: 516046316@qq.com
  • 中图分类号: X703;U664.9+2

Design and operation of und erground reclaimed water plant merging into urban eco-landscape:A case study of Ankang Jiangnan reclaimed water plant

    Corresponding author: ZHENG Cailin, 516046316@qq.com
  • 摘要: 再生水厂建设对节约水资源具有重要意义。安康市江南再生水厂为地下式再生水厂,其建设规模为8×104 m3·d−1。该再生水厂主要处理该市江南城区的生活污水,无工业有毒难降解废水,主要污染物为耗氧有机物(以COD、BOD5计)、SS、NH3-N、TN、TP等,满足可生化条件。针对生活污水的水质特点,该再生水厂采用“改良A2O+悬浮填料+高效沉淀”工艺。再生水厂出水COD和NH3-N执行地表水准IV类标准,即COD和NH3-N分别为30 mg·L−1和1.5 mg·L−1,出水其余指标执行《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级A标准。剩余污泥经“离心浓缩脱水+低温干化”处理至含水率≤60%后,进行外运处置。该再生水厂投产至今运行稳定,出水水质稳定达标。此外,该再生水厂采用地下式设计使其融入城市景观,可为同类城市的市政工程建设提供参考。
  • 加载中
  • 图 1  江南再生水厂生态综合体

    Figure 1.  Renderings of the ecological complex construction at the Jiangnan reclaimed water plant

    图 2  江南再生水厂的工艺流程图

    Figure 2.  Process flow chart of the Jiangnan reclaimed water plant

    图 3  总平面布置图

    Figure 3.  General layout

    图 4  2020年进出水水质指标的变化

    Figure 4.  Variation of water quality of influent and effluent in 2020

    表 1  设计进出水水质及处理率

    Table 1.  Designed water quality and treatment rate of at the inlet and outlet

    水质指标进水水质/
    (mg·L−1)
    出水水质/
    (mg·L−1)
    处理率/%
    BOD51201091.7
    COD3503091.4
    TN601575
    TP60.591.6
    NH3-N401.596.3
    SS2001095
      注:COD与NH3-N执行地表水Ⅳ类水标准,其余指标执行《城镇污水处理厂污染物排放标准》GB18918-2002中一级标准的A级标准。
    水质指标进水水质/
    (mg·L−1)
    出水水质/
    (mg·L−1)
    处理率/%
    BOD51201091.7
    COD3503091.4
    TN601575
    TP60.591.6
    NH3-N401.596.3
    SS2001095
      注:COD与NH3-N执行地表水Ⅳ类水标准,其余指标执行《城镇污水处理厂污染物排放标准》GB18918-2002中一级标准的A级标准。
    下载: 导出CSV

    表 2  各处理单元设计参数

    Table 2.  Design parameters of each treatment process unit

    处理单元构筑物尺寸/(m×m×m)数量工艺设计参数
    预处理单元进水井及粗格栅17.8×16.9×(18.6+6.0)1座动轨式格栅除污机近期2台,远期增加1台,栅隙宽b=15 mm;设计单渠宽1 000 mm,栅条间隙15 mm
    提升泵房16.9×14.9×(22.4+6.0)1座3台进水提升大泵流量为1 100 m3/h,扬程为15.5 m,2台小泵流量为
    590 m3/h,扬程为15.5 m
    细格栅14.5×11.0×(3.0+6.0)1座2套阶梯式网板细格栅,1套人工格栅,格栅栅隙5 mm,渠宽1.7 m
    曝气沉砂池28.0×15.0×(5.5+6.0)1座水力停留时间HRT=7 min,有效水深H=2.8 m
    精细格栅14.0×10.0×(3.55+6.0)1座设计渠宽1 800 mm,格栅栅隙为2 mm,格栅安装倾角为90°,栅前水深为1.76 m
    生物处理单元生化池95×74.7×(9.2+5.5)4座由预缺氧池、厌氧池、缺氧池、好氧池组合。总水力停留时间13.5 h,混合液MLSS含量4.0 g·L−1,污泥负荷0.065 kg,污泥回流比0~100%,混合液回流比100%~200%
    二沉池42.2×82.5×(6.15+4.5)4组表面负荷为1.13 m3·(m2·h)−1,回流污泥浓度8.0 g·L−1,有效水深4.80 m
    深度处理单元高效沉淀池20.7×46.2×(7.1+5.5)2座混合池的反应时间3 min,絮凝池的反应时间10 min,沉淀区清水区高度1.0 m,污泥回流比3%~5%
    反硝化滤池62.95×16.4×(7.1+5.5)6组反冲洗周期12~24 h,混合时间40 s
    臭氧接触池32.6×22.2×(7.75+5.5)1座臭氧接触时间:30 min,臭氧投加量为10 mg·L−1
    处理单元构筑物尺寸/(m×m×m)数量工艺设计参数
    预处理单元进水井及粗格栅17.8×16.9×(18.6+6.0)1座动轨式格栅除污机近期2台,远期增加1台,栅隙宽b=15 mm;设计单渠宽1 000 mm,栅条间隙15 mm
    提升泵房16.9×14.9×(22.4+6.0)1座3台进水提升大泵流量为1 100 m3/h,扬程为15.5 m,2台小泵流量为
    590 m3/h,扬程为15.5 m
    细格栅14.5×11.0×(3.0+6.0)1座2套阶梯式网板细格栅,1套人工格栅,格栅栅隙5 mm,渠宽1.7 m
    曝气沉砂池28.0×15.0×(5.5+6.0)1座水力停留时间HRT=7 min,有效水深H=2.8 m
    精细格栅14.0×10.0×(3.55+6.0)1座设计渠宽1 800 mm,格栅栅隙为2 mm,格栅安装倾角为90°,栅前水深为1.76 m
    生物处理单元生化池95×74.7×(9.2+5.5)4座由预缺氧池、厌氧池、缺氧池、好氧池组合。总水力停留时间13.5 h,混合液MLSS含量4.0 g·L−1,污泥负荷0.065 kg,污泥回流比0~100%,混合液回流比100%~200%
    二沉池42.2×82.5×(6.15+4.5)4组表面负荷为1.13 m3·(m2·h)−1,回流污泥浓度8.0 g·L−1,有效水深4.80 m
    深度处理单元高效沉淀池20.7×46.2×(7.1+5.5)2座混合池的反应时间3 min,絮凝池的反应时间10 min,沉淀区清水区高度1.0 m,污泥回流比3%~5%
    反硝化滤池62.95×16.4×(7.1+5.5)6组反冲洗周期12~24 h,混合时间40 s
    臭氧接触池32.6×22.2×(7.75+5.5)1座臭氧接触时间:30 min,臭氧投加量为10 mg·L−1
    下载: 导出CSV

    表 3  综合楼的采暖热负荷和空调冷负荷参数

    Table 3.  Heating and cooling load parameters of the complex building

    面积/m2冷指标/(W·m−2)冷负荷/W热指标/(W·m−2)热负荷/W
    2 500110330 000120360 000
    面积/m2冷指标/(W·m−2)冷负荷/W热指标/(W·m−2)热负荷/W
    2 500110330 000120360 000
    下载: 导出CSV

    表 4  实际进出水水质

    Table 4.  Actual water quality of influent and effluent sewage

    水质指标进水水质/(mg·L−1)进水水质/(mg·L−1)处理率/%
    BOD51286.594.9
    COD3321994.3
    TN595.890.2
    TP5.80.1896.9
    NH3-N390.3599.1
    SS286697.9
    水质指标进水水质/(mg·L−1)进水水质/(mg·L−1)处理率/%
    BOD51286.594.9
    COD3321994.3
    TN595.890.2
    TP5.80.1896.9
    NH3-N390.3599.1
    SS286697.9
    下载: 导出CSV
  • [1] 王文龙, 吴乾元, 杜烨, 等. 城市污水中新兴微量有机污染物控制目标与再生处理技术[J]. 环境科学研究, 2021, 34(7): 1672-1678.
    [2] 赵静. 城镇污水二级处理和再生水厂三级处理综合毒性削减[D]. 大连: 大连理工大学, 2019.
    [3] 王会生. 推动下沉式再生水厂建设变"邻避效应"为正能量[J]. 国际融资, 2019(4): 17-18.
    [4] GB/T 18918—2002, 《城镇污水处理厂污染物排放标准》[S].
    [5] WILSON D. Underground solution for wastewater treatment plant[J]. Tunnels and Tunnelling, 1994, 26(11): 24-26.
    [6] 孙世昌, 汪翠萍, 王凯军. 地下式污水处理厂的研究现状及关键问题探讨[J]. 给水排水, 2016, 42(6): 37-41. doi: 10.3969/j.issn.1002-8471.2016.06.008
    [7] JOHANSSON E J W. Treating sewage underground[J]. Tunnels and Tunnelling, 1995, 27(7): 21-23.
    [8] 梁玉华, 任大银. 环境科普基地建设意义、面临问题及建设措施探讨[J]. 贵州师范学院学报, 2015, 31(3): 72-75. doi: 10.3969/j.issn.1674-7798.2015.03.020
    [9] 施卫娟, 李培培. 金港地下污水处理厂工程建设及设计特点[J]. 中国给水排水, 2013, 29(18): 81-83.
    [10] 北京市市政工程设计研究总院. 给水排水设计手册: 城镇排水[M]. 北京: 中国建筑工业出版社, 2004.
    [11] 戴仲怡, 李瑞成, 王建兴, 等. 多段强化脱氮A2/O工艺用于大型半地下式污水处理厂[J]. 中国给水排水, 2017, 33(16): 75-78.
    [12] 王雪, 戴仲怡, 张晓临, 等. A2/O+MBR工艺用于集约化高排放标准半地下式污水厂[J]. 中国给水排水, 2020, 36(4): 53-56.
    [13] 阮丽峰. 工业园区地下式污水处理厂工程设计[J]. 城市道桥与防洪, 2020(1): 75-77.
    [14] 刘梦嘉, 宋哗皓. 浅析公园式污水处理厂对缓解邻避效应的作用—以成都市天府新区为例[J]. 当代建筑, 2020(5): 134-137.
  • 加载中
图( 4) 表( 4)
计量
  • 文章访问数:  3813
  • HTML全文浏览数:  3813
  • PDF下载数:  67
  • 施引文献:  0
出版历程
  • 收稿日期:  2020-12-08
  • 录用日期:  2021-07-06
  • 刊出日期:  2021-09-10
郑才林, 江慧, 陈浩, 郑文雅, 周龙飞, 张旭, 彭文涛, 王业飞. 融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例[J]. 环境工程学报, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
引用本文: 郑才林, 江慧, 陈浩, 郑文雅, 周龙飞, 张旭, 彭文涛, 王业飞. 融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例[J]. 环境工程学报, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
ZHENG Cailin, JIANG Hui, CHEN Hao, ZHENG Wenya, ZHOU Longfei, ZHANG Xu, PENG Wentao, WANG Yefei. Design and operation of und erground reclaimed water plant merging into urban eco-landscape:A case study of Ankang Jiangnan reclaimed water plant[J]. Chinese Journal of Environmental Engineering, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031
Citation: ZHENG Cailin, JIANG Hui, CHEN Hao, ZHENG Wenya, ZHOU Longfei, ZHANG Xu, PENG Wentao, WANG Yefei. Design and operation of und erground reclaimed water plant merging into urban eco-landscape:A case study of Ankang Jiangnan reclaimed water plant[J]. Chinese Journal of Environmental Engineering, 2021, 15(9): 3125-3132. doi: 10.12030/j.cjee.202012031

融入城市生态景观的地下式再生水厂设计与运行——以安康市江南再生水厂为例

    通讯作者: 郑才林, E-mail: 516046316@qq.com
    作者简介: 郑才林(1981—),男,大学本科,高级工程师。研究方向:市政技术与管理。E-mail:516046316@qq.com
  • 1. 安康市市政园林处,安康 725000
  • 2. 西安建筑科技大学环境与市政工程学院,西安 710055
  • 3. 安康安信水环境发展有限公司,安康 725000
  • 4. 安康市城镇污水垃圾处理监测中心,安康 725000

摘要: 再生水厂建设对节约水资源具有重要意义。安康市江南再生水厂为地下式再生水厂,其建设规模为8×104 m3·d−1。该再生水厂主要处理该市江南城区的生活污水,无工业有毒难降解废水,主要污染物为耗氧有机物(以COD、BOD5计)、SS、NH3-N、TN、TP等,满足可生化条件。针对生活污水的水质特点,该再生水厂采用“改良A2O+悬浮填料+高效沉淀”工艺。再生水厂出水COD和NH3-N执行地表水准IV类标准,即COD和NH3-N分别为30 mg·L−1和1.5 mg·L−1,出水其余指标执行《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级A标准。剩余污泥经“离心浓缩脱水+低温干化”处理至含水率≤60%后,进行外运处置。该再生水厂投产至今运行稳定,出水水质稳定达标。此外,该再生水厂采用地下式设计使其融入城市景观,可为同类城市的市政工程建设提供参考。

English Abstract

  • 城市污水再生利用是缓解城市缺水问题、改善城市水环境质量的重要措施[1]。再生水作为“城市第二水源”已越来越被公众接受,并在很多城市得以倡导[2]。2016年,《中华人民共和国水法(2016修正)》中多次提到,加强城镇污水集中处理,并鼓励使用回用水,提高回用水利用率[2]

    安康市位于汉江上游,汉江在安康境内干流长度为346 km。这段干流流域是南水北调中线工程的核心水源涵养区,承担着“一江清水供津京”重任,因此,安康市的水质保护工作意义重大。近年来,随着城区人口增多,配套市政设施日益完善,污水量随之增大,位于安康市江南片区的江南污水处理厂处理容量将达极限,急需开展污水处理厂的升级改造工作。该污水处理厂所在位置为城区金州广场北侧,周边建筑密集,已无拓展用地,很难实施水质提标改造或进行处理规模的扩展。同时,该厂的地表污水处理、设备运行产生的噪声已影响到周边区域的发展。依据创建“自然环境与人工环境共生”生态型城市的理念,结合本市的发展规划,安康市对原江南污水处理厂进行迁址,并扩能重建为江南再生水厂。

    江南再生水厂为地下式再生水厂。水厂上方建设水生态公园与水环境科普馆,具有环境友好、节约土地、资源再利用等特点[3]。水厂自建成以来,运行稳定,出水水质达标。在2020年新冠肺炎疫情爆发期间,再生水厂切断了病毒与自然水体、环境的接触,凸显了地下式再生水厂在应对突发公共卫生事件中的优势。本文旨在解构江南再生水厂工程中各主要处理构筑物的设计参数,分析工程工艺和运行效果,为西北地区类似污水再生工程的改造设计提供参考。

    • 安康市江南再生水厂设计规模8×104 m3·d−1,近期设备安装规模6×104 m3·d−1,其中再生水规模1.2×104 m3·d−1。再生水厂采用“改良A2O工艺+矩形沉淀池+高效沉淀池+反硝化滤池”工艺,并采用高效生物复合除臭与污泥低温干化等先进技术。出水标准执行《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准[4]。其中,COD、氨氮可达到地表水Ⅳ类水标准。处理后的再生水可用于城市景观用水等。

    • 传统的地上式再生水厂的建设应满足《城市排水工程规划规范》(GB50318-2000)的卫生防护距离要求,以避免潜在的臭味、噪音污染,以及与周边自然景观不协调等问题[5-6]。为不影响周边建设用地的生产发展,与汉江水环境、自然景观相协调,江南再生水厂采用地下式建设方案。本项目处理规模8.0×104 m3·d−1,占地6.8×104 m2,为传统地上式再生水厂占地面积的2/3。由于该项目为地下式再生水厂,工程建设时无需考虑绿化及隔离带等要求,节省了卫生防护用地。江南再生水厂生态综合体的建设效果图及实景照片见图1

      该厂为西北地区第一座地下式再生水厂。地下式再生水厂具有节约土地资源,节省管网投资,视觉、噪声和臭气污染小,运行稳定、方便回收利用余热,利用地上景观设计提升周边土地价值等优点[6-7]。水厂的地面部分建设主题公园和水环境科普馆,可用于普及水环境科学知识,传播绿色发展理念,满足公众对高质量环保科普产品和科普服务水平的需求[8-9]。余热利用单元亦是地下式再生水厂的一大优势。采用污水源热泵空调机组利用低品位热源——污水作为冷热源,可实现冬季采暖和夏季制冷,充分利用污水中的热量;使用过程中没有燃煤、燃气等锅炉房的燃烧,也避免了排烟污染,充分体现了该厂“绿色工程”的形象。

    • 本项目采用实测法及类比法进行水质分析论证,综合分析原江南污水厂台账,将再生水厂设计进、出水水质及处理率数据汇总,见表1

    • 江南再生水厂的污水生化处理流程采用“改良A2O+悬浮填料”工艺。悬浮填料上的生物膜和悬浮活性污泥共同去除水中的污染物;辅以HERO高效复合生物技术进行臭味处理;采用“紫外线消毒+次氯酸钠消毒”技术进行消毒,确保出水安全。厂区的地面部分为生态休闲公园,可解决“邻避效应”以提升周边土地价值。利用水源热泵技术,可将污水处理过程中的能量进行交换利用;利用绿色低碳污水源热泵技术生态节能,充分利用污水中的热能,实现采暖制冷过程不耗电,且满足周边市政建筑的制冷与供热。具体工艺流程图见图2

    • 基于进水水质和出水标准的要求,再生水厂工程对BOD5、COD、SS、TN、TP和NH3-N等指标对应污染物的去除率至少达到91.7%、91.4%、95%、75%、91.6%和96.3%。这说明,不仅要求BOD5、COD、SS等指标对应污染物去除率较高,对TN、TP、NH3-N等指标也提出了严格的控制要求,即需要在去除常规污染物的基础上增加脱氮除磷工艺。与传统工艺相比,“改良A2/O+悬浮填料”工艺结合了传统活性污泥法及生物接触氧化法的优点,弥补了2种工艺的不足,耐冲击负荷能力更强,污染物去除效果更好,氧气利用率更高,主要特点总结如下。

      1)耐冲击性强,性能稳定,运行可靠。冲击负荷及温度变化对流化填料的影响要远远小于对传统活性污泥法的影响。生物膜对污水中成分变化,或污水毒性增加的耐受力较强。

      2)容积负荷高,紧凑省地。容积负荷取决于生物填料的有效比表面积。不同填料的比表面积相差很大,变化范围为500~1 200 m2·m−3,可适应不同预处理要求和应用情况。

      3)工艺参数可灵活变化。本工艺可灵活选择不同填料填充率,以达到在无需增大池容的前提下兼顾处理效率及远期扩大处理规模的需求。

      4)使用寿命长。优质耐用的生物填料及出水装置可保证整个系统长期使用,而无需频繁更换,折旧率低。

    • 江南再生水厂的主要构筑物有[10]:粗格栅井及提升泵房、细格栅渠及曝气沉砂池、精细格栅、生化池、二沉池、高效沉淀池、反硝化滤池及臭氧接触池。各单元设计工艺见表2

      江南再生水厂全厂污水处理构筑物区域采用组合式布置[11-12],组合体采用半地下式结构设计,顶部主要用于环保科普,中间层为操作层,下部为水池[12]。水厂上方建设水生态公园与水环境科普馆,集水质净化、生态景观、休闲运动、科普教育为一体[13]。根据工艺流程及场地功能,把全厂分为2个部分:生产管理区和生产处理区。考虑到防洪要求及周边道路的地面标高,厂区的场地设计标高定为247.5 m。江南再生水厂总平面布置图如图3

    • 以污水作为提取和储存能量的介质,借助热泵机组的循环热交换,将污水中的低品位热能转换为高品位热能,用于采暖或制冷,以减少电能的消耗。采暖和制冷服务主要供给该厂的综合楼。工程主要设备包括热泵机组、污水专用宽流道换热器、污水泵、中介循环泵、系统水循环泵、软化水设备、水箱等,机组及相关设备设在热泵机房。热泵机组设置2台,不设备用机组,每台机组负荷率按65%考虑。当其中1台机组发生故障时,另1台机组可满足65%负荷进行供冷供热,符合设计规范要求。污水泵由工艺专业选配,选用潜污泵2用1备,将中水送到热泵机房,经换热器后回到清水池下游。综合楼的面积为2 500 m2,对该建筑的采暖热负荷及空调冷负荷采用冷热指标进行估算。根据空调的冷指标(110 W·m−2)热指标(120 W·m−2),分别得到冷负荷为330 000 W,热负荷为360 000 W。

      根据计算,每天每处理1×104 t污水,对应热泵机组可提供约5 000 kW的热量。污水处理量以1.2×104 m3·d−1计,采暖季120 d,标准煤发热29 307 kJ·kg−1,锅炉效率0.8,制热能效比(COP)取4,生产1 kW·h电标准煤耗量0.33 kg,因此,煤耗量计算如下。

      采暖季总供热量:$ Q=5\;000\times 1.2\times 24\times 3\;600\times 120=6.2\times {10}^{10}\;\mathrm{k}\mathrm{J} $

      采用锅炉供暖的标准煤耗量:$ {Q}_{{标准煤}}=\dfrac{6.2\times {10}^{10}\;\mathrm{k}\mathrm{J}}{0.8\times 29\;307\;\mathrm{k}\mathrm{J} \cdot {\mathrm{k}\mathrm{g}}^{-1}}=2\;644.4\;\mathrm{t} $

      采用热泵供暖耗电量:$ {Q}_{{电}}=\dfrac{6.2\times {10}^{10}\;\mathrm{k}\mathrm{J}}{3\;600\times 4}=4.31\times {10}^{6}\;\mathrm{k}\mathrm{W} \cdot \mathrm{h} $

      采用热泵供暖的标煤耗量:$ G=4.31\times {10}^{6}\;\mathrm{k}\mathrm{W} \cdot \mathrm{h}\times 0.33\;\mathrm{k}\mathrm{g} \cdot (\mathrm{k}\mathrm{W} \cdot \mathrm{h}{)}^{-1}=1\;422.3 \;{\rm{t}}$

      综上所述,整个采暖季采用热泵供暖可节约标准煤耗量为:$ 2\;644.4-1\;422.3=1\;222.1 $ t。

    • 根据工程投资估算,建设项目总投资5.878 0×104万元。其中:工程费4.288 3×104万元、建设项目其他费用1.136 7×104万元、基本预备费2.401×103万元、建设期利息1. 967×103万元,铺底流动资金为162.00万元;再生水厂工程平均年处理总成本费用5.999×103万元;平均年经营成本费用3.350×103万元。本项目运行成本为每吨水1.60元。据市场行情计算,污水源热泵采暖成本为1元·m−2,运营成本约在15元·m−2,市政供暖按供热面积收费标准25元·m−2计算,则采用污水源热泵供暖可节约36%的成本。

    • 该工程自2018年8月开工建设,2019年10月正式投产运营,自投入运行至今,安全稳定运行、出水稳定达标、除臭效果显著。该厂实际进、出水水质及处理率见表4

      实际运行数据表明,江南再生水厂的出水水质能稳定达到《城镇污水处理厂污染物排放标准》GB18918-2002中一级标准的A级标准。各种污染物指标的去除率均达到90%以上,其中氨氮的去除效率最高,可达99.1%。以2020年为例,该厂进出水COD、氨氮、总磷、总氮,以及去除率如图4所示。由图4可知,经该厂处理后的出水COD、氨氮、总磷、总氮等指标大幅下降,平均降低90%以上,去除效果明显,超额完成设计处理率,出水水质达标。

    • 江南再生水厂采用地下式再生水生产技术,不仅实现了传统污水处理厂的功能,而且避免了占地、臭气、噪声等“邻避效应”[14]。该工程将污水处理设施与地上生态环境有机结合,并通过污水余热利用实现了热量的回收,节约了传统化石燃料的消耗,打造成以地下式再生水厂为核心的新型生态综合体。该厂的建成充分体现了绿色环保理念,对改善安康城市水环境质量、提升城市人居环境、提升城市品味、确保汉江水质稳定达标具有重要意义,可为同类再生水厂的建设提供参考。

    参考文献 (14)

返回顶部

目录

/

返回文章
返回