    作者简介: 田家宇 (1979—) ,男,博士,教授,tjy800112@163.com
    通讯作者: 高珊珊(1981—),女,博士,高级工程师,gsjy_2010@163.com
  • 基金项目:
    国家自然科学基金面上项目(52370035);河北省自然科学基金项目(E2023202064);广东省重点领域研发计划项目(2022B0101090004)
  • 中图分类号: X703.1

Effective control of membrane fouling in MBR with flat-sheet ceramic membrane—Effect of particle size of activated carbon

    Corresponding author: GAO Shanshan, gsjy_2010@163.com
  • 摘要: 采用机械强度高、耐刮擦性能好的平板陶瓷膜,构建了膜生物反应器(MBR)城市污水处理系统,对比研究了颗粒活性炭(GAC)和粉末活性炭(PAC)在膜污染控制与污染物去除中的作用。结果表明,GAC组在运行初期由于颗粒炭较强的刮擦作用表现出较好的膜污染减缓效果,跨膜压(TMP)增长速率降低17%,但中后期效果不明显。PAC组在运行中后期展现出明显的抗污染优势,TMP增速降低了28%。机理分析结果表明,PAC组混合液中胞外聚合物(EPS)含量降低了49%,污泥絮体平均粒径增大了102 μm。此外,PAC的投加使得MBR总氮(TN)去除率提升了17%,COD去除率也有所提高。研究结果为平板陶瓷膜MBR膜污染的优化控制与高效运行提供了技术支持。
  • 加载中
  • 图 1  反应装置示意图

    Figure 1.  Schematic diagram of the reaction unit

    图 2  TMP增长曲线

    Figure 2.  Graph of TMP growth

    图 3  膜阻力分析

    Figure 3.  Membrane resistance analysis

    图 4  膜表面污染层SEM图

    Figure 4.  SEM images of the fouling layer on the membrane surface

    图 5  活性炭对EPS和SMP的影响

    Figure 5.  Effect of activated carbon on EPS and SMP

    图 6  反应器中EPS的EEM光谱 (40 d)

    Figure 6.  EEM spectra of EPS in the reactor (40 d)

    图 7  污泥粒径分析

    Figure 7.  Sludge particle size analysis

    图 8  不同反应器对COD、NH4+-N、TN的去除效果

    Figure 8.  Removal effect of COD, NH4+-N and TN by different reactors

    图 9  细菌群落在门级和属级的分类

    Figure 9.  Bacterial communities at the phylum and genus levels

    表 1  膜污染速率比较

    Table 1.  Comparison of membrane contamination rates (kPa·d)−1

    阶段空白PACGAC
    第1阶段10.236.875.70
    第2阶段4.963.644.85
    第3阶段32.6123.2031.58
    阶段空白PACGAC
    第1阶段10.236.875.70
    第2阶段4.963.644.85
    第3阶段32.6123.2031.58
    下载: 导出CSV

    表 2  不同样品多样性指数统计表

    Table 2.  Statistics of diversity indices of different samples

    样品 序列数 OTUs Shannon Chao Simpson Shannoneven 覆盖率
    空白 381 69 740 4.78 764.1 0.045 63 0.724 2 0.998 7
    PAC 308 27 721 5.31 738.2 0.017 39 0.806 6 0.998 6
    GAC 336 50 695 4.85 769.6 0.020 46 0.741 3 0.997 0
    样品 序列数 OTUs Shannon Chao Simpson Shannoneven 覆盖率
    空白 381 69 740 4.78 764.1 0.045 63 0.724 2 0.998 7
    PAC 308 27 721 5.31 738.2 0.017 39 0.806 6 0.998 6
    GAC 336 50 695 4.85 769.6 0.020 46 0.741 3 0.997 0
    下载: 导出CSV
  • [1] MARTI-CALATAYUD M C, SCHNEIDER S, YUCE S, et al. Interplay between physical cleaning, membrane pore size and fluid rheology during the evolution of fouling in membrane bioreactors[J]. Water Research, 2018, 147: 393-402. doi: 10.1016/j.watres.2018.10.017
    [2] 张雷, 田雪咏, 史立伟. MBR膜污染防治策略研究现状[J]. 环境工程, 2023, 41(S41): 174-178.
    [3] 林静芳, 张新颖, 张莉敏. MBR工程长期运行中的膜清洗效果和膜性能变化[J]. 中国给水排水, 2022, 38(3): 67-73.
    [4] DU X, SHI Y, JEGATHEESAN V, et al. A review on the mechanism, impacts and control methods of membrane fouling in MBR system[J]. Membranes (Basel), 2020, 10(2): 24. doi: 10.3390/membranes10020020
    [5] ZHANG S, XIONG J, ZUO X, et al. Characteristics of the sludge filterability and microbial composition in PAC hybrid MBR: Effect of PAC replenishment ratio[J]. Biochemical Engineering Journal, 2019, 145: 10-17. doi: 10.1016/j.bej.2019.02.001
    [6] WU B, ZAMANI F, LIM W, et al. Effect of mechanical scouring by granular activated carbon (GAC) on membrane fouling mitigation[J]. Desalination, 2017, 403: 80-87. doi: 10.1016/j.desal.2015.12.003
    [7] MOHAMADI S, HAZRATI H, SHAYEGAN J. Influence of a new method of applying adsorbents on membrane fouling in MBR systems[J]. Water and Environment Journal, 2019, 34: 355-366.
    [8] 杨洁, 李旋坤, 李光辉. 陶瓷膜的膜污染机制与控制技术研究进展[J]. 工业水处理, 2023, 43(45): 49-15.
    [9] 张锐, 江静, 徐鸿飞. 陶瓷膜分离技术及其在生物制造领域的应用进展[J]. 化工进展, 2024, 44: 1-14.
    [10] GENG M, YOU S, GUO H, et al. Impact of fungal pellets dosage on long-term stability of aerobic granular sludge[J]. Bioresource Technology, 2021, 332: 125106. doi: 10.1016/j.biortech.2021.125106
    [11] INGMAR H H, BENOIT D KENNETH M P, et al. Water permeability in ultrafiltration and microfiltration: Viscous and electroviscous effects[J]. Desalination, 1997, 113(1): 95-103. doi: 10.1016/S0011-9164(97)00118-5
    [12] GRELIER P, ROSENBERGER S, TAZI-PAIN A. Influence of sludge retention time on membrane bioreactor hydraulic performance[J]. Desalination, 2006, 192: 10-17. doi: 10.1016/j.desal.2005.04.131
    [13] SUN Y, TIAN J, ZHAO Z, et al. Membrane fouling of forward osmosis (FO) membrane for municipal wastewater treatment: A comparison between direct FO and OMBR[J]. Water Research, 2016, 104: 330-339. doi: 10.1016/j.watres.2016.08.039
    [14] 范辉, 高燕宁, 刘克成. 生物载体缓解管式膜MBR工艺中的膜污染[J]. 净水技术, 2023, 42(2): 103-108.
    [15] AL-HALBOUNI D, TRABER J, LYKO S, et al. Correlation of EPS content in activated sludge at different sludge retention times with membrane fouling phenomena[J]. Water Research, 2008, 42: 1475-1488. doi: 10.1016/j.watres.2007.10.026
    [16] REMY M, VAN DER MAREL P, ZWIJNENBURG A, et al. Low dose powdered activated carbon addition at high sludge retention times to reduce fouling in membrane bioreactors[J]. Water Research, 2009, 43: 345-350. doi: 10.1016/j.watres.2008.10.033
    [17] YANG G, HUANG L, YU Z, et al. Anode potentials regulate Geobacter biofilms: New insights from the composition and spatial structure of extracellular polymeric substances[J]. Water Research, 2019, 159: 294-301. doi: 10.1016/j.watres.2019.05.027
    [18] FENG H J, CHEN L, YING X B, et al. The impact of powdered activated carbon types on membrane anti-fouling mechanism in membrane bioreactors[J]. Applied Microbiology and Biotechnology, 2022, 106: 7337-7345. doi: 10.1007/s00253-022-12186-5
    [19] ZHANG S, ZUO X, XIONG J, et al. Effect of powdered activated carbon dosage on sludge properties and membrane bioreactor performance in a hybrid MBR-PAC system[J]. Environmental Technology, 2019, 40: 1156-1165. doi: 10.1080/09593330.2017.1417493
    [20] SATYAWALI Y, BALAKRISHNAN M. Effect of PAC addition on sludge properties in an MBR treating high strength wastewater[J]. Water Research, 2009, 43: 1577-1588. doi: 10.1016/j.watres.2009.01.003
    [21] HUANG R, PAN H, ZHENG X, et al. Effect of membrane pore size on membrane fouling of corundum ceramic membrane in MBR[J]. International Journal of Environmental Research and Public Health, 2023, 20(5): 4558. doi: 10.3390/ijerph20054558
    [22] SUN H, LIU H, HAN J, et al. Chemical cleaning-associated generation of dissolved organic matter and halogenated byproducts in ceramic MBR: Ozone versus hypochlorite[J]. Water Research, 2018, 140: 243-250. doi: 10.1016/j.watres.2018.04.050
    [23] SUN H, LIU H, WANG S, et al. Ceramic membrane fouling by dissolved organic matter generated during on-line chemical cleaning with ozone in MBR[J]. Water Research, 2018, 146: 328-336. doi: 10.1016/j.watres.2018.09.001
    [24] VAN DEN BROECK R, VAN DIERDONCK J, NIJSKENS P, et al. The influence of solids retention time on activated sludge bioflocculation and membrane fouling in a membrane bioreactor (MBR)[J]. Journal of Membrane Science, 2012, 401-402: 48-55. doi: 10.1016/j.memsci.2012.01.028
    [25] 许桃, 刘鹏举, 梁潇. 染料类型对膜生物反应器性能的影响[J]. 环境工程学报, 2022, 16(4): 1381-1390.
    [26] TANG S, LI J, ZHANG Z, et al. Comparison of long-term ceramic membrane bioreactors without and with in-situ ozonation in wastewater treatment: Membrane fouling, effluent quality and microbial community[J]. Science of the Total Environment, 2019, 652: 788-799. doi: 10.1016/j.scitotenv.2018.10.284
    [27] MARTí-CALATAYUD M C, HEßLER R, SCHNEIDER S, et al. Transients of micropollutant removal from high-strength wastewaters in PAC-assisted MBR and MBR coupled with high-retention membranes[J]. Separation and Purification Technology, 2020, 246: 116863. doi: 10.1016/j.seppur.2020.116863
    [28] MARKARIAN A, CARRIèRE A, DALLAIRE P, et al. Hybrid membrane process: Performance evaluation of biological PAC[J]. Journal of Water Supply:Research and Technology - Aqua, 2010, 59: 209-220. doi: 10.2166/aqua.2010.087
    [29] SKOUTERIS G, SAROJ D, MELIDIS P, et al. The effect of activated carbon addition on membrane bioreactor processes for wastewater treatment and reclamation: A critical review[J]. Bioresource Technology, 2015, 185: 399-410. doi: 10.1016/j.biortech.2015.03.010
    [30] ALVARINO T, TORREGROSA N, OMIL F, et al. Assessing the feasibility of two hybrid MBR systems using PAC for removing macro and micropollutants[J]. Journal of Environmental Management, 2017, 203: 831-837.
    [31] TANG B, YU C, BIN L, et al. Essential factors of an integrated moving bed biofilm reactor-membrane bioreactor: Adhesion characteristics and microbial community of the biofilm[J]. Bioresource Technology, 2016, 211: 574-583. doi: 10.1016/j.biortech.2016.03.136
    [32] ZHU Y, ZHANG Y, REN H Q, et al. Physicochemical characteristics and microbial community evolution of biofilms during the start-up period in a moving bed biofilm reactor[J]. Bioresource Technology, 2015, 180: 345-351. doi: 10.1016/j.biortech.2015.01.006
    [33] MIUARA Y , WATANABE Y , OKABE S. Significance of chloroflexi in performance of submerged membrane bioreactors (MBR) treating municipal wastewater[J]. Environmental Science & Technology, 2007, 41: 7787-7794.
    [34] REN B, LI C, ZHANG X, et al. Fe(II)-dosed ceramic membrane bioreactor for wastewater treatment: Nutrient removal, microbial community and membrane fouling analysis[J]. Science of the Total Environment, 2019, 664: 116-126. doi: 10.1016/j.scitotenv.2019.02.019
    [35] PENG C, HUANG H, GAO Y, et al. A novel start-up strategy for mixotrophic denitrification biofilters by rhamnolipid and its performance on denitrification of low C/N wastewater[J]. Chemosphere, 2020, 239: 124726. doi: 10.1016/j.chemosphere.2019.124726
  • 加载中
图( 9) 表( 2)
计量
  • 文章访问数:  1097
  • HTML全文浏览数:  1097
  • PDF下载数:  42
  • 施引文献:  0
出版历程
  • 收稿日期:  2023-01-13
  • 录用日期:  2024-02-07
  • 刊出日期:  2024-05-26

平板陶瓷膜MBR膜污染优化控制—活性炭粒径的影响

    通讯作者: 高珊珊(1981—),女,博士,高级工程师,gsjy_2010@163.com
    作者简介: 田家宇 (1979—) ,男,博士,教授,tjy800112@163.com
  • 1. 河北工业大学土木与交通学院,天津 300401
  • 2. 广东粤海水务股份有限公司,深圳 518021
基金项目:
国家自然科学基金面上项目(52370035);河北省自然科学基金项目(E2023202064);广东省重点领域研发计划项目(2022B0101090004)

摘要: 采用机械强度高、耐刮擦性能好的平板陶瓷膜,构建了膜生物反应器(MBR)城市污水处理系统,对比研究了颗粒活性炭(GAC)和粉末活性炭(PAC)在膜污染控制与污染物去除中的作用。结果表明,GAC组在运行初期由于颗粒炭较强的刮擦作用表现出较好的膜污染减缓效果,跨膜压(TMP)增长速率降低17%,但中后期效果不明显。PAC组在运行中后期展现出明显的抗污染优势,TMP增速降低了28%。机理分析结果表明,PAC组混合液中胞外聚合物(EPS)含量降低了49%,污泥絮体平均粒径增大了102 μm。此外,PAC的投加使得MBR总氮(TN)去除率提升了17%,COD去除率也有所提高。研究结果为平板陶瓷膜MBR膜污染的优化控制与高效运行提供了技术支持。

English Abstract

  • 与传统活性污泥法处理系统相比, MBR具有占地面积小、处理效率高、脱氮效果好的优势[1-2],在水处理领域受到越来越多的关注。然而,高TMP增长和因膜污染导致的运行成本增加、维护难度增大问题,已成为 MBR推广应用的主要障碍[3-4]。目前,研究人员已探索出多种控制膜污染的策略,如优化运行条件(包括调整曝气策略、间歇抽吸、定时反冲洗等),在反应器中投加生物载体以改善污泥性能等。活性炭具有吸附性好、比表面积大等优势,同时目前研究表明,在MBR中添加活性炭能有效减缓膜污染[5],延长MBR的运行周期。

    根据现有研究,在生物反应器中添加活性炭可能会产生以下影响:1)冲刷膜表面,对滤饼层形成有抑制效果[6];2)吸附作用可降低上清液中溶解性有机物(如SMP(soluble microbial products)和EPS)的质量浓度[7];3)增强活性污泥的聚集,改变污泥絮体的粒径分布,使其尺寸更大[4]。但是,活性炭的投加会对有机高分子膜表面造成损伤,因此在传统有机膜MBR中较少使用。平板陶瓷膜具有使用寿命长,化学、机械和热稳定性好的优点,在MBR中展现出较好的应用前景[8-9]。然而,关于活性炭粒度对平板陶瓷膜MBR膜污染的影响还少有研究。

    针对以上问题,本论文从TMP增长速率、污泥混合液EPS含量、污泥粒径、滤饼层形貌、微生物种群等方面展开了系统研究,阐释了PAC和GAC在MBR运行过程中对膜污染控制和除污染效能的影响,研究结果可为平板陶瓷膜MBR的有效应用提供理论和技术支持。

    • PAC和GAC购自麦克林品牌,尺寸分别为 200目和12目。实验用平板陶瓷膜由白刚玉骨料经捏合、挤出、高温烧结制成。反应器中活性污泥取自深圳市福田污水厂。实验中采用葡萄糖、氯化铵、磷酸二氢钾配制城市生活污水,其中COD值为(350±50) mg·L−1,NH4+-N为(30±5) mg·L−1,总磷为(4.5±0.5) mg·L−1。实验运行中,通过加入NaHCO3调控进水pH在合理范围(6.5~8.5)。

    • 实验采用浸没式MBR 装置,如图1所示,反应器尺寸为长×宽×高=180 mm×85 mm×300 mm,有效容积为 1.8 L。内置平板陶瓷膜,膜面积为 0.007 0 m2,膜的平均孔径为0.63 μm,纯水通量为8 000 L·(m2·h·bar)−1。通过气泵进行曝气,维持溶解氧在3~4 mg·L−1。根据预实验结果,研究中平板陶瓷膜的运行通量设置为25 L·(m2·h)−1,抽吸模式为 8 min 开/2 min 关。采用压力传感器和无纸记录仪实时记录 TMP 的变化。

    • 设置空白组(不投加活性炭)、PAC 组、GAC 组,反应器中活性污泥质量浓度为12 g·L−1,活性炭量为2 g·L−1。水力停留时间为8.5 h,通过定期排泥和补充活性炭的方式维持悬浮液质量浓度恒定。

    • 每运行48 h取系统水样进行检测,氨氮(NH4+-N)、亚硝态氮(NO2-N)、硝态氮(NO3-N)采用紫外分光光度法(INESA L5,上海仪电,中国)测定,COD、TN采用哈希分光光度计(HACH DR3 900,哈希公司,美国)测定。

      取 50 mL 污泥混合液,于 10 000 r·min−1下离心 5 min,上清液经0.45 µm 滤膜过滤可得到SMP。EPS的提取采用3步热提取技术[10]。SMP 和 EPS 中的多糖(polysaccharides,PS)和蛋白质(proteins,PN)分别采用苯酚-硫酸法和Lowery法测定。对于膜表面泥饼层中的EPS,首先用海绵将泥饼层擦下,于离心管中用去离子水定容至50 mL,然后采用3步热提取技术进行提取及后续测定。

      利用荧光分光光度计(EEM,F-7 000FL,日立公司,日本)对 SMP 和 EPS 进行三维荧光光谱(excitation-emission-matrix spectra,EEM)分析,其中激发波长为 200~450 nm,发射波长为 220~550 nm。根据国标法测定的活性污泥质量浓度(mixed liquor suspended solids,MLSS)。采用激光粒度仪(Malvern Mastersizer 2 000,马尔文公司,英国)测定污泥絮体粒径分布。通过压力传感器记录的压力和单位时间内收集的膜出水体积,根据达西定律(式(1)~(2))[11]计算总过滤阻力(Rt)、滤饼层阻力(Rc)、孔内阻力(Rp)及不可逆阻力(Ri)。

      式中:Rt 为总过滤阻力,m−1J为渗透通量,L·(m2·h)−1;∆P为跨膜压,Pa;μ是水的粘度系数,Pa·s。

      在运行结束后,采用扫描电子显微镜(SEM,ZEISS Gemini 300,蔡司公司,德国)对污染膜表面进行 SEM 观察。观察前对膜进行如下预处理:1)浸泡在 pH=6.8,2.5%的戊二醛溶液中,于 4 ℃放置2 h;2)经0.1mmol·L−1的磷酸盐缓冲液(PBS)冲洗3次,每次10~15 min;3)用50%、70%、80%、90%乙醇溶液依次对样品进行脱水处理,每次10~15 min,再用100%乙醇脱水3次,每次10~15 min;4) 60 ℃烘干,观察前进行喷金处理。

    • 1) TMP增长。TMP增长趋势能较为直观地反映膜污染情况,图2显示了60 d内3个反应器的TMP增长情况。就TMP增长速率而言,可将膜污染分为3个阶段,各阶段TMP增长速率如表1所示。在第1阶段,凝胶层迅速在膜表面沉积,TMP快速增长,这与其他学者[12]揭示的膜污染特性相符。投加活性炭的实验组TMP增长慢于空白,其中GAC-MBR组TMP增长最缓慢,平均增速比空白组慢4.5 kPa·d−1。这是由于GAC具有较大粒径,在混合液中产生额外的剪切力,对膜表面产生刮擦作用进而抑制凝胶层生成。在第2阶段,膜表面凝胶层的形成使污染物难以进入膜孔,TMP增长缓慢且平稳。在第3阶段,由于不可逆膜污染的形成及污泥混合液EPS含量增加,膜污染速率显著加快。在第2、3阶段,PAC-MBR组TMP增长最缓慢,GAC-MBR与空白组差异不明显,说明PAC对缓解膜污染具有长期优势,这是由于PAC的吸附和凝聚作用可降低混合液EPS质量浓度、增大污泥粒径,从而有效减缓膜污染。

      2)膜阻力分析。对于恒通量过滤系统,可以用膜阻力分布反映膜污染特性。如图3所示,在运行初期,所有MBR的滤饼层阻力在总阻力中均占较大比例,说明滤饼层污染是膜污染的主要原因[13]。与投加活性炭的反应器相比,空白组的孔内阻力与不可逆阻力随着运行时间的延长呈现出较快的增长趋势。在运行40 d时,空白组的膜过滤总阻力高于PAC组近84%,高于GAC组28%。PAC的存在使反应器中以悬浮形态存在的污泥数量减少,这也是滤饼层阻力和孔内阻力增长较慢的原因[14]

      3) SEM分析。在运行60 d时,使用SEM对污染的陶瓷膜表面进行微观形貌表征。如图4所示,在污染较重的空白组膜表面可以观察到较为致密的滤饼层和EPS附着物,PAC组则可较清晰地观察到膜孔结构以及较薄的滤饼层厚度,这与其较低的膜污染速率相一致,而GAC组的污染层形态介于空白组与PAC组之间。

    • 1) EPS分析。在膜生物反应器的运行过程中,微生物生长活动会产生EPS,活性污泥中的EPS以及上清液中的SMP被认为会通过膜孔堵塞以及促进膜表面形成滤饼层而导致膜污染[15]。由图5可以看出,EPS和SMP中的PS和PN含量随着运行时间的推移呈上升趋势,这也很好地解释了MBR运行的中后期膜污染速率变快的原因。但是,投加PAC之后,PAC-MBR组无论是EPS还是SMP中的PS和PN含量均显著降低,较之空白组分别降低了49%和23%;相应地,膜表面污染层中PS和PN的平均含量也比空白组降低了11%。PAC的投加之所以能降低反应器中EPS的含量及其在膜表面的富集,主要原因归为以下3点:1)PAC的吸附作用,定期补充更新的PAC可吸附PS和PN等大分子EPS物质,进而有效降低其在反应器中的含量,而颗粒尺寸较大的GAC则吸附容量较低;2)生物活性炭(BPAC)的形成,PAC在混合液中起到载体和团聚的作用[16],将活性污泥逐渐由悬浮絮体形态转化为生物膜形态,从而减少EPS和SMP的分泌[17];3)微生物活性,具有还原性的PAC可以调节微生物活性[18],从而在MBR中发挥更强的生物降解作用[19]。与此同时,PAC-MBR组污泥混合液的PN/PS值增加,这有利于增强污泥的疏水性,促进更大尺寸污泥颗粒的形成,也能起到减缓膜污染的作用[14,20]

      图6显示了从反应器中提取的EPS三维荧光光谱图。在发射波长/激发波长为280 nm/340 nm和230 nm/350 nm处发现了2个不同的蛋白质峰,分别属于色氨酸类物质(峰A)和酪氨酸类物质(峰B)[21-22]。可以看出,无论是峰A还是峰B,PAC-MBR组的荧光强度均为最低,GAC组与空白组之间未呈现出明显差异。不仅如此,在空白组和GAC组中出现了腐殖质(C峰,350/425 nm),而该峰在PAC组中没有出现。之前的研究发现,平均分子质量为 500 kDa的腐殖质也是造成膜污染的主要原因[23]。这表明PAC的加入可有效降低反应器中的多种膜污染相关有机物,从而减缓了MBR的膜污染。

      2)污泥粒径分析。由图7可见,在运行的20 d、40 d测量混合污泥粒径,与空白组相比,添加活性炭后反应器中的污泥粒径均有不同程度的增加,但由于曝气的原因,运行后期3个反应器的活性污泥粒径又有减小的趋势。整个运行过程中,空白组的平均污泥粒径为96 μm,PAC组为198 μm。有研究[24-25]表明,污泥粒径越小,形成的滤饼层越紧密,膜污染越严重。大的絮体难以附着在膜表面,从而抑制滤饼层的形成[26]。同时,投加的PAC可为微生物提供强有力的支撑,使污泥聚集体更加坚固致密,与不含活性炭的弱聚集体相比,强污泥聚集体释放的膜污染物更少,从而减缓膜的污染[27]。此外,污泥絮体尺度的变化可导致微生物群落结构发生相应改变,从而对膜污染产生影响[28],详见2.4部分。

    • 图8为连续运行60 d后COD、NH4+-N、TN去除率的变化情况。实验中进水COD值稳定在 300~400 mg·L−1,出水稳定在20 mg·L−1以下,去除率高达 95%。投加活性炭的实验组COD去除率略高于空白组, PAC组去除效果好于GAC 组。其主要原因是生物活性炭(BPAC)的生成,运行过程中往往会在PAC表面形成1层稳定的微生物膜,从而可提高对污染物的去除率[29]。同时,小粒径的PAC提供了更大的表面积,可促进微生物菌群定植,更好地发挥物理吸附和生物降解作用。

      在溶解氧维持在3~4 mg·L−1的条件下,3组反应器出水中未检测到NO2-N,NH4+-N出水质量浓度没有显著差异,但发现3组反应器出水NO3-N质量浓度存在显著差异,2组投加活性炭反应器的出水NO3-N质量浓度一直低于空白组。PAC的加入使TN的去除率提高了约17%,这是由于PAC表面生物膜层的形成和生长创造了有利于反硝化进行的缺氧区[30],为反硝化微生物的代谢活动提供了更为适宜的微环境。

    • 接下来研究了活性炭对MBR中微生物群落的多样性、组成和结构的影响,Illumina HiSeq测序分析结果如表2所示。Chao和Shannon指数通常用于估算 OTU 数量的变化,数量越多,物种来源越丰富。Shannon和Simpson指数主要用于比较微生物物种的多样性和同质性[31],投加活性炭的实验组相较于空白组显示出更高的微生物物种丰度。

      图9可见,在门水平上,3个MBR中最主要的4个物种分别是变形菌门(Proteobacteria)、放线菌门(Planctomycetes)、类杆菌门(Bacteroidetes)和酸性菌门(Acidobacteria)。以往的研究发现,反硝化的主要功能菌门是平面菌门(Planctomycetes)和类杆菌门。本研究中,PAC-MBR 组中类杆菌门的相对含量较高(17.03%),与其较高的TN去除率相一致。另外值得注意的是,在添加活性炭的反应器中,变形菌所占比例有所下降。此外,PAC组放线菌含量最低,绿弯菌含量最高,已知放线菌可增加EPS含量和粘附性[32],绿弯菌可降解SMP物质[33]。以上结果从微生物学角度证实了PAC在减缓膜污染方面的有效性。

      在属水平上,PAC-MBR中碱铁杆菌(Ferriginibacter)、装甲菌(Armatimonadetes)和噬氢菌(Hydrogenophaga)的比例较高,其中装甲菌有利于微生物反硝化作用的进行[5, 34],噬氢菌在一些固相脱氮生物膜系统中含量较高,还可去除生物膜反应器中的硝酸盐和有机物[35],这为PAC组较高的脱氮效果进一步提供了合理的微生物学解释。

    • 1) PAC在MBR中具有较好的膜污染减缓效果,运行中后期TMP增长速率与空白组相比降低了28%,这是由于PAC的投加使得混合液中EPS和SMP质量浓度分别降低了49%和23%,污泥絮体尺度增大了102 μm,进而导致膜表面污染层厚度较小,且更为疏松。

      2) GAC对MBR膜污染的影响在运行初期较为显著,这是由于大颗粒活性炭可对膜表面形成冲刷刮擦,有利于减缓凝胶层的形成;但在膜表面形成凝胶层之后,冲刷效果不再明显,且由于比重较大,GAC难以稳定维持悬浮状态,导致缓解膜污染的作用减弱。

      3) PAC-MBR组中COD去除率不仅有所提高,TN去除效果也得以明显改善(相对空白组提升17%,平均去除率达到75%),这可归因于PAC表面生物膜的形成,既可增强生物降解作用,也有利于反硝化缺氧微区域的形成,进而富集出较高丰度的脱氮功能菌群。